Publications by authors named "Bruce Robie"

Background: Decompressive surgery has a failure rate of between 25% and 32% based on patient reported improvement in clinical symptoms. Significant back pain is associated with 53% of failures of decompressive surgery, while also being associated with abnormal axial rotation motion. We report on the clinical performance of subjects receiving a novel axial rotation stabilization implant (ARO Spinal System, ARO Medical), while undergoing a surgical decompression for a herniated lumbar disc, a condition associated with low back pain and abnormal movement.

View Article and Find Full Text PDF

Introduction: Clinical research has documented that cage subsidence and the loss of balance correction is a significant complication related to spinal fusion. Subsidence is a multifactorial complication, where implant design is one important element. The aim of the study is to compare the rigidity and bone-implant relative motion of segments treated with either a conventional one-piece ALIF cage versus a two-piece ALIF cage, which adapts in situ and permits 7°-21° of lordosis.

View Article and Find Full Text PDF

Objectives: Evaluation of bacterial adhesion to pure tantalum and tantalum-coated stainless steel versus commercially pure titanium, titanium alloy (Ti-6Al-4V), and grit-blasted and polished stainless steel.

Design: Experimental in vitro cell culture study using Staphylococcus aureus and Staphylococcus epidermidis to evaluate qualitatively and quantitatively bacterial adherence to metallic implants.

Methods: A bacterial adhesion assay was performed by culturing S.

View Article and Find Full Text PDF

Dislocation following hip arthroplasty remains problematic. While the etiology of dislocation may be multifactorial, implant system design may play a role. Using a computer aided design program, virtual range of motion of several commonly implanted designs was performed with prosthetic interference representing impingement used as an endpoint.

View Article and Find Full Text PDF

The purpose of this study was to devise and implement an accurate and reproducible method of measuring the area and dimensions of the rotator cuff tendon insertions and their distance from the articular surface. Twenty fresh-frozen cadaveric upper-extremity specimens were divided into 2 groups of 10. In group 1 the specimens were dissected, leaving only the most distal rotator cuff tendons attached to the humerus.

View Article and Find Full Text PDF