Publications by authors named "Bruce B Reid"

Objective: Although regurgitant mitral valves can be repaired through surgical or transcatheter approaches, contemporary comparative outcomes are limited with the impact of residual and recurrent mitral regurgitation (MR) on clinical outcomes being poorly defined. We hypothesized that moderate (2+) or greater residual or recurrent (RR) MR-regardless of type of repair-predicts worse clinical outcomes.

Methods: Our institutional experience of 660 consecutive patients undergoing mitral valve repair (2015-2021) consisting of 393 surgical mitral valve repair (SMVr) and 267 transcatheter edge-to-edge mitral valve repair (TEER) was studied.

View Article and Find Full Text PDF

Objectives: The purpose of this study was to define anterior mitral leaflet (AML) length and mitral ring characteristics associated with LVOT obstruction and PVL following MViR.

Background: Transcatheter Mitral Valve in Ring (MViR) procedural complications including parvalvular leak (PVL) and left ventricular outflow tract (LVOT) obstruction are frequent.

Methods: Clinical records, computer tomographic scans (CTs) and echocardiograms of consecutive MViR patients were retrospectively reviewed for anterior mitral leaflet length, CT-simulated neoLVOT, and aortomitral angle among patients with and without MViR-induced LVOT obstruction.

View Article and Find Full Text PDF

Objectives: The purpose of this study was to evaluate the safety and efficacy of valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR) for stentless bioprosthetic aortic valves (SBAVs) and to identify predictors of adverse events.

Background: ViV TAVR in SBAVs is associated with unique technical challenges and risks.

Methods: Clinical records and computer tomographic scans were retrospectively reviewed for procedural complications, predictors of coronary obstruction, mortality, and echocardiographic results.

View Article and Find Full Text PDF

Background: Gastrointestinal bleeding (GIB) is a leading cause of morbidity during continuous-flow left ventricular assist device (CF-LVAD) support. GIB risk assessment could have important implications for candidate selection, informed consent, and postimplant therapeutic strategies. The aim of the study is to derive and validate a predictive model of GIB in CF-LVAD patients.

View Article and Find Full Text PDF

Background: Small-scale studies focused mainly on nonischemic cardiomyopathy (NICM) have shown that a subset of left ventricular assist device (LVAD) patients can achieve significant improvement of their native heart function, but the impact of ischemic cardiomyopathy (ICM) has not been specifically investigated. Many patients with acute myocardial infarction are discharged from their index hospitalization without heart failure (HF), only to return much later with overt HF syndrome, mainly caused by chronic remodeling of the noninfarcted region of the myocardium.

Objectives: This study sought to prospectively investigate the effect of ICM HF etiology on LVAD-associated improvement of cardiac structure and function using NICM as control.

View Article and Find Full Text PDF

Background: Immune allosensitization can be triggered by continuous-flow left ventricular assist devices (CF LVAD). However, the effect of this type of allosensitization on post-transplant outcomes remains controversial. This study examined the post-transplant course in a contemporary cohort of patients undergoing transplantation with and without LVAD bridging.

View Article and Find Full Text PDF

Background: Antibody-mediated rejection (AMR) in cardiac transplant recipients is a serious form of rejection with adverse patient outcomes. The International Society of Heart and Lung Transplantation (ISHLT) has published a consensus schema for the pathologic diagnosis of various grades of antibody-mediated rejection (pathology antibody-mediated rejection [pAMR]). We sought to determine whether the ISHLT pAMR grading schema correlates with patient outcomes.

View Article and Find Full Text PDF

Background: Ventricular assist devices (VADs) have a proven survival benefit in select patients with advanced heart failure, yet many patients considered for implantation are declined for various reasons. The outcome of these patients is obscure owing to their exclusion from recent VAD studies. We aim to compare the outcomes of patients who received a VAD to those who did not.

View Article and Find Full Text PDF

Background: The elevated baseline heart rate (HR) of a heart transplant recipient has previously been considered inconsequential. However, we hypothesized that a resting HR above 100 beats per minute (bpm) may be associated with morbidity and mortality.

Methods: The U.

View Article and Find Full Text PDF

Longevity and quality of life for left ventricular assist device (LVAD) patients are plagued by driveline exit site infections. Ultraviolet (UV) radiation, a current treatment in wound healing clinics, could potentially treat LVAD exit site infections. However, the effect of UV radiation on the tensile properties of HeartMate II (HMII) driveline material is unknown.

View Article and Find Full Text PDF

We report a case of combined acute and chronic dissection limited to the pulmonary autograft 10 years after a Ross procedure, managed by replacement with a stentless porcine bioprosthesis. Implications for timing and technique of reintervention for pulmonary autograft dilatation are discussed.

View Article and Find Full Text PDF

Background: Driveline exit site (DLES) infection is a major complication of ventricular assist devices (VADs). Differences in the sheath material interfacing with exit site tissue appear to affect healing time and infection risk more than site hygiene, but the mechanistic basis for this is not clear.

Methods: Health record data from Utah Artificial Heart Program patients with HeartMate II (HMII) devices implanted from 2008 to 2012 were retrospectively reviewed, with particular attention to interface type, incorporation (healing) time, and infections.

View Article and Find Full Text PDF

Background: In animal models of heterotopic transplantation, mechanical unloading of the normal, nonhypertrophic heart results in atrophy. Primarily on the basis of these animal data, the notion that chronic left ventricular assist device (LVAD)-induced unloading will result in atrophy has dominated the clinical heart failure field, and anti-atrophic drugs have been used to enhance the cardiac recovery potential observed in some LVAD patients. However, whether unloading-induced atrophy in experimental normal heart models applies to failing and hypertrophic myocardium in heart failure patients unloaded by continuous-flow LVADs has not been studied.

View Article and Find Full Text PDF

Non-invasive imaging techniques are highly desirable as an alternative to conventional biopsy for the characterization of the remodeling of tissues associated with disease progression, including end-stage heart failure. Cardiac diffusion tensor imaging (DTI) has become an established method for the characterization of myocardial microstructure. However, the relationships between diffuse myocardial fibrosis, which is a key biomarker for staging and treatment planning of the failing heart, and measured DTI parameters have yet to be investigated systematically.

View Article and Find Full Text PDF

Objectives: This study sought to prospectively investigate the longitudinal effects of continuous-flow left ventricular assist device (LVAD) unloading on myocardial structure and systolic and diastolic function.

Background: The magnitude, timeline, and sustainability of changes induced by continuous-flow LVAD on the structure and function of the failing human heart are unknown.

Methods: Eighty consecutive patients with clinical characteristics consistent with chronic heart failure requiring implantation of a continuous-flow LVAD were prospectively enrolled.

View Article and Find Full Text PDF

Background: Bleeding is an important cause of morbidity and mortality in patients with continuous-flow left ventricular assist devices (LVADs). Reduced pulsatility has been implicated as a contributing cause. The aim of this study was to assess the effects of different degrees of pulsatility on the incidence of nonsurgical bleeding.

View Article and Find Full Text PDF

Infection of a prosthetic graft after replacement of the ascending aorta is an uncommon but life-threatening complication of surgery. We report the use of antibiotic-impregnated calcium sulfate beads in a patient with ascending aortic graft infection to provide localized, high-dose therapy to the infected region. Perigraft placement of antibiotic beads provides an alternative method for the treatment of aortic graft infection.

View Article and Find Full Text PDF

Background: Growing evidence suggests worse cardiac allograft vasculopathy and mortality in patients with asymptomatic antibody-mediated rejection (AMR). Debate continues about whether therapeutic intervention is warranted to avoid adverse outcomes. In this study we examine the course of individual episodes of untreated asymptomatic AMR on follow-up endomyocardial biopsy (EMB).

View Article and Find Full Text PDF

Background: Both pulsatile-flow and continuous-flow left ventricular assist devices (LVADs) successfully provide patients a bridge to transplantation. Some data suggest that continuous-flow pumps increase the risk of allograft rejection, contributing to posttransplantation morbidity and mortality. We sought to analyze the relationship between LVAD flow characteristics and subsequent allograft rejection in bridge to transplant (BTT) patients.

View Article and Find Full Text PDF

Background: The HeartMate II (HMII) left ventricular assist device (LVAD) has proven reliable and durable and has become the preferred choice for bridge to transplant therapy (BTT) when compared with the pulsatile HeartMate XVE (XVE). In this study, we compared the post-transplant (PTx) outcomes between XVE and HMII using a large national data registry.

Methods: The Organ Procurement and Transplantation Network (OPTN)/United Network for Organ Sharing (UNOS) Thoracic Registry database was queried for all patients implanted with either an XVE or an HMII as BTT during 2004-2009.

View Article and Find Full Text PDF

Background: Recent efforts are being undertaken to update and refine current diagnostic criteria for antibody-mediated rejection (AMR) in heart transplantation. We believe that the appropriate reactants are those that best predict the adverse consequences of AMR and therefore tested various models using different reactants to find the best predictors of cardiovascular mortality in pathologically defined AMR.

Methods: The study group included only patients in whom all immunofluorescence antibodies of interest had been tested on biopsy specimens obtained after 2002 when C4d was routinely added.

View Article and Find Full Text PDF

Background: The use of left ventricular assist devices (LVADs) as destination therapy (DT) is increasing and has proven beneficial in prolonging survival and improving quality of life in select patients with end-stage heart failure. Nonetheless, end-of-life (EOL) issues are inevitable and how to approach them underreported.

Methods: Our DT data registry was queried for eligible patients, defined as those individuals who actively participated in EOL decision making.

View Article and Find Full Text PDF

Objectives: This study investigates alterations in myocardial microvasculature, fibrosis, and hypertrophy before and after mechanical unloading of the failing human heart.

Background: Recent studies demonstrated the pathophysiologic importance and significant mechanistic links among microvasculature, fibrosis, and hypertrophy during the cardiac remodeling process. The effect of left ventricular assist device (LVAD) unloading on cardiac endothelium and microvasculature is unknown, and its influence on fibrosis and hypertrophy regression to the point of atrophy is controversial.

View Article and Find Full Text PDF