Objectives: During computed tomography (CT), a large amount of ionizing radiation is emitted to ensure high quality of the obtained radiological image. This study measured the dose distribution around the CT scanner and the exposure of people staying near the CT scanner during the examination.
Material And Methods: The measurements used an anthropomorphic phantom to assess human exposure to ionizing radiation.
Objectives: The study aim was to analyse the influence of the lead free cap on doses received by interventional cardiologists. The impact of lead free cap on doses to the head were evaluated in number of studies. As different methods used to assess the attenuation properties of protective cap can lead to ambiguous results, a detailed study was performed.
View Article and Find Full Text PDFCoefficients converting the readings of the whole body dosemeter worn on the left arm to eye lens doses were determined by analysing the correlations between Hp(10) and Hp(3) values. Doses were measured on a phantom for specific C-arm projections typically used during CA/PCI procedures. In order to estimate the cumulative eye lens doses, conversion coefficients were then applied to the dose records of interventional cardiologists collected in the database of dosimetry service between the years 1995 and 2009.
View Article and Find Full Text PDFIntroduction: Radon-induced biological effects have been studied mainly through epidemiological investigations, and well-controlled in vitro and in vivo experiments. To provide data explaining radon exposure-induced harmful effects in natural environment, exposure assessment under these conditions is needed. The objective of the study was to examine the level of genetic damage assessed with biomarkers of DNA single- and double-strand breaks (SSBs and DSBs) in peripheral blood mononuclear cells obtained from individuals continuously exposed to Rn in homes.
View Article and Find Full Text PDFIn the study the modulating effect of inhibition of phosphatidylinositol 3-kinase-related kinases (PIKK): ATM (Ataxia Telangiectasia Mutated), ATR (Ataxia Telangiectasia and Rad3 Related) and DNA-PK (DNA-dependent protein kinase) on genotoxicity of dibenzo[def,p]chrysene (DBC) in HepG2 human hepatocellular cancer cells was investigated. The cytotoxicity of DBC was determined, also in combination with PIKK inhibitors, using the MTT reduction assay. The high cytotoxicity of DBC was observed after 72 h incubation (IC = 0.
View Article and Find Full Text PDFIn 2016, the EURADOS working group 12 started a project to gather reliable data concerning the behavior of active personal dosemeters (APDs) used by European hospitals in standardized pulsed and hospital fields. This paper concentrates on the tests that deal with the dose rate dependence of APDs in laboratory tests. The dependence on the dose rate was determined for 10 dosemeter types with continuous radiation of a 60Co source and pulsed radiation of the reference radiation facility of Physikalisch-Technische Bundesanstalt.
View Article and Find Full Text PDFThe calibration of low energy X-ray experimental setup with strongly filtered beam dedicated to radiobiological research was performed using the absorbed dose calculated from the data collected by two types detectors. For this purpose a semiconductor (Amptek, USA) and a thermoluminescent (Institute of Nuclear Physics, Krakow, Poland) detectors were applied. The absorbed dose in water values estimated by both detectors are in good agreement.
View Article and Find Full Text PDFIn the context of a new annual eye lens dose limit for occupational exposure equal to 20 mSv, European Radiation Dosimetry Group (EURADOS) organized an intercomparison dedicated to eye lens dosemeters, including photon and beta radiations. The objective was to complete the first intercomparison recently organized by EURADOS for photons and to update the overview of eye lens dosemeters available in Europe. The dosemeters provided by the 22 participants coming from 12 countries were all composed of thermoluminescent detectors.
View Article and Find Full Text PDFIn fluoroscopy guided interventional procedures, workers use protective garments and often two personal dosemeters, the readings of which are used for the estimation of the effective dose; whereas the dosemeter above the protection can be used for the estimation of the equivalent dose of the lens of the eye. When a protective apron is worn the scattered field that reaches the dosemeter is different from the case where no protection is used; this study analyses the changes in the response of seven passive and eight active personal dosemeters (APDs) when they are placed above a lead or lead equivalent garment for S-Cs and x-ray diagnostic qualities. Monte Carlo simulations are used to support the experimental results.
View Article and Find Full Text PDFThe aim of the present study is to analyse quantitatively the potential reduction of doses to the eye lens and the hands of an operator and a nurse by the use of a pelvic lead blanket during coronary angiography (CA) and percutaneous transluminal coronary angioplasty (PTCA) procedures. Thermoluminescent dosimeters were used to assess dose levels to the left eye lens and fingers on both hands of both physician and nurses during single procedures performed with or without the lead blanket. The measurements were carried out at one medical centre and include dosimetric data from 100 procedures.
View Article and Find Full Text PDFThe dose reduction factors (DRF) for different types of lead glasses and C-arm units with x-ray tubes placed above the patient table were calculated from the results of measurements by loose thermoluminescent dosimeters (TLDs) and EYE-D dosimeters using a Rando phantom. The DRF values were analysed for different positions of routine dosimeters worn outside lead eyewear and confronted with DRFs calculated as the ratio of the dose equivalent to the eye measured with and without the eyewear. Moreover, for eye lens dosimeters designed to be worn behind lead glasses, multiplicative factors for various positions of dosimeter were derived in order to account for the differences between the doses measured on the inner side of the glasses and the dose equivalent to the eye lens.
View Article and Find Full Text PDFThe current system of dosimetric quantities has been defined by the International Commission on Radiological Protection (ICRP) and the International Commission on Radiation Units and Measurements (ICRU). Complexity of the system implies the physical nature of ionizing radiation, resulting from the presence of different types of radiation of different ionization capabilities, as well as the individual radiation sensitivity of biological material exposed. According to the latest recommendations, there are three types of dosimeter quantities relevant to radiation protection and radiological assessment of occupational exposure.
View Article and Find Full Text PDFThe aim of this study was to investigate the effect of static magnetic fields (SMF) on reactive oxygen species induced by X-ray radiation. The experiments were performed on lymphocytes from male albino Wistar rats. After exposure to 3 Gy X-ray radiation (with a dose rate of 560 mGy/min) the measurement of intracellular reactive oxygen species in lymphocytes, using a fluorescent probe, was done before exposure to the SMF, and after 15 min, 1 and 2 h of exposure to the SMF or a corresponding incubation time.
View Article and Find Full Text PDFBackground: Effective diagnostic radiology system should be based on an efficient and suitable servicing of medical X-ray equipment. According to Polish requirements, all radiology departments are obligated to carry out quality control (QC) test of their X-ray set. In practice, testing is mostly performed by accredited external QC services, which have to participate in periodic interlaboratory comparison (ILC) to maintain or obtain the accreditation.
View Article and Find Full Text PDFThe main objective of WP1 of the ORAMED (Optimization of RAdiation protection for MEDical staff) project is to obtain a set of standardised data on extremity and eye lens doses for staff in interventional radiology (IR) and cardiology (IC) and to optimise staff protection. A coordinated measurement program in different hospitals in Europe will help towards this direction. This study aims at analysing the first results of the measurement campaign performed in IR and IC procedures in 34 European hospitals.
View Article and Find Full Text PDF