Introduction: High-quality evidence is crucial for guiding effective humanitarian responses, yet conducting rigorous research, particularly randomised controlled trials, in humanitarian crises remains challenging. The TISA ("traitement intégré de la sous-nutrition aiguë") trial aimed to evaluate the impact of a Water, Sanitation and Hygiene (WASH) intervention on the standard national treatment of uncomplicated Severe Acute Malnutrition (SAM) in children aged 6-59 months. Implemented in two northern Senegalese regions from December 22, 2021, to February 20, 2023, the trial faced numerous challenges, which this paper explores along with the lessons learned.
View Article and Find Full Text PDFSevere acute malnutrition (SAM) is a high-fatality condition that affected 13.7 million children under five years of age worldwide in 2022, with complicated cases requiring extensive inpatient stay with an accompanying caregiver. Our objective was to assess the costs of inpatient treatment for complicated SAM in children aged 6 to 59 months in Northern Senegal and identify cost predictors.
View Article and Find Full Text PDFAmong the key diseases affecting the asparagus crop ( L.), vascular wilting of asparagus caused by f. sp.
View Article and Find Full Text PDFIn the placement of dental implants, the primary fixation between the dental implant and the bone is of great importance and corresponds to compressive mechanical fixation that aims to prevent micromovement of the implant. The aim of this research was to determine the role of roughness and the type of dental implant (tissue-level or bone-level) in implant stability, measured using resonance frequency analysis (RFA) and insertion torque (IT). We analyzed 234 titanium dental implants, placed in fresh calf ribs, at the half-tissue level and half-bone level.
View Article and Find Full Text PDFBacterial infections in dental implants generate peri-implantitis disease that causes bone loss and the mobility of the dental implant. It is well known that specific ranges of roughness favor the proliferation of bacteria, and it is for this reason that new dental implants called hybrids have appeared. These implants have a smooth area in the coronal part and a rough surface in the apical part.
View Article and Find Full Text PDFOne of the strategies for the fight against peri-implantitis is the fabrication of titanium dental implants with the part close to the neck without roughness. It is well known that roughness favors osseointegration but hinders the formation of biofilm. Implants with this type of structure are called hybrid dental implants, which sacrifice better coronal osseointegration for a smooth surface that hinders bacterial colonization.
View Article and Find Full Text PDFMetal ion release studies were carried out on three of the most commonly used orthodontic wires in the clinic: austenitic stainless steel, Ti-Mo, and superelastic NiTi, using three mouthwashes with different fluoride concentrations: 130, 200, and 380 ppm. Immersions were carried out in these mouthwashes at 37 °C for 1, 4, 7, and 14 days, and the ions released were determined by inductively coupled plasma-mass spectrometry (ICP-MS). All wires were observed by scanning electron microscopy (SEM).
View Article and Find Full Text PDFDigital dentistry and new techniques for the dental protheses' suprastructure fabrication have undergone a great evolution in recent years, revolutionizing the quality of dental prostheses. The aim of this work is to determine whether the best horizontal marginal fit is provided by the CAD-CAM technique or by laser sintering. These values have been compared with the traditional casting technique.
View Article and Find Full Text PDFSpain is the fourth largest lettuce-producing country in the world and the leading European producer. Much of the production, mainly grow in open field, is dedicated to export with a value of 887 million U.S.
View Article and Find Full Text PDFThe major problems for the osseointegration of dental implants are the loosening of the screw that fixes the dental implant to the abutment and the micromovements that are generated when mechanical loads are applied. In this work, torque differences in the tightening and loosening of the connection screws after 1 cycle, 10 cycles and 1000 cycles for 4 dental implants with 2 external and 2 internal connections were analyzed. The loosening of 240 implants (60 for each system) was determined using high-precision torsimeters and an electromechanical testing machine.
View Article and Find Full Text PDFTitanium mini-implants are used as anchorage for orthodontic tooth movements. However, these implants present problems due to the infection of surrounding tissues. The aim of this work was to obtain a polyethylene glycol (PEG) layer by plasma in order to achieve a bacteriostatic surface.
View Article and Find Full Text PDFThe use of a PMMA composite with graphene is being commercialized for application as dental prostheses. The different proportions of fibers provide a wide range of colors that favors dental esthetics in prostheses. However, there are no studies that have explained the influence that graphene has on the mechanical properties.
View Article and Find Full Text PDFThe techniques used in oral implantology to remove bacterial biofilm from the surface of implants by machining the titanium surface (implantoplasty) or by placing rough dental implants through friction with the cortical bone generate a large release of particles. In this work, we performed a simulation of particle generation following clinical protocols. The particles were characterized for commercially pure titanium with particle sizes of 5, 10, 15, and 30 μm.
View Article and Find Full Text PDFMany studies are being carried out on the particles released during the implantoplasty process in the machining of dental implants to remove bacterial biofilms. However, there are no studies on the release of particles produced by the insertion of bone-level dental implants due to the high compressive frictional loads between the rough titanium implant and the bone tissue. This paper aims to characterize the released particles and determine the release of titanium ions into the physiological environment and their cytocompatibility.
View Article and Find Full Text PDFThe procedure generally used to remove bacterial biofilm adhering to the surface of titanium on dental implants is implantoplasty. This treatment is based on the machining of the titanium surface to remove bacterial plaque. In this study, we used 60 grade 4 titanium implants and performed the implantoplasty protocol.
View Article and Find Full Text PDFThe purpose of this research is to study the biomechanical response of dental implants in bone-level type locations, 0.5 mm above and below the bone level. In addition, the influence of the thickness of the cortical bone on osseointegration is determined due to the mechanical loads transfer from the dental implant to the cortical and trabecular bone.
View Article and Find Full Text PDFAsparagus crop is distributed worldwide, covering very different climatic regions. Among the different diseases that affect asparagus, vascular wilt, caused by f. sp.
View Article and Find Full Text PDFAsparagus Decline Syndrome (ADS) is one of the main phytosanitary problems of asparagus crop worldwide. Diseased plants and soil samples from 41 fields from three main production areas of Spain were surveyed. Eight species belonging to seven species complexes were identified in soils: , , , , , , and .
View Article and Find Full Text PDFThe load transfer from metallic prosthesis to tissue plays an important role in the success of a designed device. From a mechanical behavior point of view, the load transfer will be favored when the elastic modulus between the metallic implant and the bone tissue are similar. Titanium and Ti-6Al-4V are the most commonly used metals and alloys in the field of dental implants, although they present high elastic moduli and hence trigger bone resorption.
View Article and Find Full Text PDFBackground: For patients whose centric relation (CR) has not been considered at the start and during treatment, the task of achieving an occlusal scheme that works together with the temporomandibular joint, the muscles, and the structures of the stomatognathic apparatus becomes a major concern.
Objective: This study aims to describe a reproducible, predictable and to date unreported procedure of selective grinding guided by an occlusal splint and to analyze condylar position (CP) based on the skeletal pattern.
Methods: A total of 72 symptomatic patients (38 females and 34 males) were classified into three groups: hyperdivergent, intermediate and hypodivergent.
The virtual technique described in this article integrates reverse engineering and mandibular dynamics into dental computer-aided design and computer-aided manufacturing (CAD-CAM) systems. This technique aims to provide more objective information to the dental technician for the diagnosis, planning, and treatment phases. In order to carry out this protocol, the following devices, currently available in many practices, are necessary: an intraoral scanner, a T-Scan system, and some specific open reverse engineering software.
View Article and Find Full Text PDFThe purpose of this study was to locate the 3D spatial position mandibular cast and determine its occlusal contacts in a novel way by using an intraoral scanner as part of the virtual occlusal record procedure. This study also analyzes the requirements in quantity and dimensions of the intraoral virtual occlusal record. The results showed that the best section combination consists of 2 lateral and frontal sections, the width of this section being that of 2 teeth (24 mm × 15 mm).
View Article and Find Full Text PDFOrthod Craniofac Res
February 2016
Objectives: To assess the effects of local delivery of recombinant fusion protein osteoprotegerin (OPG-Fc) and bisphosphonate zoledronate on bone and periodontal ligament in a rat tooth movement model.
Materials And Methods: Maxillary first molars of 36 male Sprague-Dawley rats were displaced mesially using a calibrated spring connected to an anterior mini-screw. Two different drugs were used: a single dose of Zoledronate (16 μg) and a twice-weekly dose of OPG-Fc (5.
Statement Of Problem: Conventional methods associated with many processes in dentistry are being replaced by methods that use digital technology. One of these processes is the making of occlusal records for the positioning of casts in a virtual articulator. Conventional interocclusal records and the articulator are currently being replaced by the intraoral virtual occlusal record and the virtual articulator.
View Article and Find Full Text PDF