Publications by authors named "Brian Nutter"

The I21 beamline at Diamond Light Source is dedicated to advanced resonant inelastic X-ray scattering (RIXS) for probing charge, orbital, spin and lattice excitations in materials across condensed matter physics, applied sciences and chemistry. Both the beamline and the RIXS spectrometer employ divergent variable-line-spacing gratings covering a broad energy range of 280-3000 eV. A combined energy resolution of ∼35 meV (16 meV) is readily achieved at 930 eV (530 eV) owing to the optimized optics and the mechanics.

View Article and Find Full Text PDF

Currently, functional magnetic resonance imaging (fMRI) is the most commonly used technique for obtaining dynamic information about the brain. However, because of the complexity of the data, it is often difficult to directly visualize the temporal aspect of the fMRI data. We outline a -distributed stochastic neighbor embedding (t-SNE)-based postprocessing technique that can be used for visualization of temporal information from a 4D fMRI data.

View Article and Find Full Text PDF

Through the last three decades, functional magnetic resonance imaging (fMRI) has provided immense quantities of information about the dynamics of the brain, functional brain mapping, and resting-state brain networks. Despite providing such rich functional information, fMRI is still not a commonly used clinical technique due to inaccuracy involved in analysis of extremely noisy data. However, ongoing developments in deep learning techniques suggest potential improvements and better performance in many different domains.

View Article and Find Full Text PDF
Article Synopsis
  • The text describes a newly commissioned four-bounce crystal monochromator for the XAS beamline at Diamond Light Source, featuring a unique design with two independent rotary axes.
  • The device maintains flux throughput without external feedback from 4 to 20 keV and is currently equipped with cryogenically cooled Si(111) crystals.
  • Preliminary designs allow for the potential installation of an additional Si(311) crystal-set to increase the energy range to 34 keV, with experimental data supporting its mechanical stability and repeatability.
View Article and Find Full Text PDF

The design and implementation of a compact and portable sample alignment system suitable for use at both synchrotron and free-electron laser (FEL) sources and its performance are described. The system provides the ability to quickly and reliably deliver large numbers of samples using the minimum amount of sample possible, through positioning of fixed target arrays into the X-ray beam. The combination of high-precision stages, high-quality sample viewing, a fast controller and a software layer overcome many of the challenges associated with sample alignment.

View Article and Find Full Text PDF

X-ray optics, based on a double-crystal deflection scheme, that enable reflectivity measurements from liquid surfaces/interfaces have been designed, built and commissioned on beamline I07 at Diamond Light Source. This system is able to deflect the beam onto a fixed sample position located at the centre of a five-circle diffractometer. Thus the incident angle can be easily varied without moving the sample, and the reflected beam is tracked either by a moving Pilatus 100K detector mounted on the diffractometer arm or by a stationary Pilatus 2M detector positioned appropriately for small-angle scattering.

View Article and Find Full Text PDF

Objective: Visual assessment of digitized cervigrams through the Internet needs to be optimized. The National Cancer Institute and National Library of Medicine are involved in a large effort to improve colposcopic assessment and, in preparation, are conducting methodologic research.

Materials And Methods: We selected 50 cervigrams with diagnoses ranging from normal to cervical intraepithelial neoplasia 3 or invasive cancer.

View Article and Find Full Text PDF

Objective: To demonstrate compression, illumination enhancement, registration, segmentation, automated classification and steganography using digitized cervical images.

Materials And Methods: The Hybrid Multi-Scale Vector Quantization algorithm developed at Texas Technological University and other automated systems were used to improve digitized cervical images.

Results: We demonstrated high levels of image compression, illumination enhancement, registration, automated segmentation and classification and steganography of digitized cervical images.

View Article and Find Full Text PDF

A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_session4scgcrhjm41h8j4c0htr6lb4s5lu7aaf): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once