We present a versatile new instrument capable of measuring rovibrational transition frequencies of molecular ions with sub-MHz accuracy and precision. A liquid-nitrogen cooled positive column discharge cell, which can produce large column densities of a wide variety of molecular ions, is probed with sub-Doppler spectroscopy enabled by a high-power optical parametric oscillator locked to a moderate finesse external cavity. Frequency modulation (heterodyne) spectroscopy is employed to reduce intensity fluctuations due to the cavity lock, and velocity modulation spectroscopy permits ion-neutral discrimination.
View Article and Find Full Text PDFSpectroscopy of the ν1 band of the astrophysically relevant ion HCO(+) is performed with an optical parametric oscillator calibrated with an optical frequency comb. The sub-MHz accuracy of this technique was confirmed by performing a combination differences analysis with the acquired rovibrational data and comparing the results to known ground-state rotational transitions. A similar combination differences analysis was performed from the same data set to calculate the previously unobserved rotational spectrum of the ν1 vibrationally excited state with precision sufficient for astronomical detection.
View Article and Find Full Text PDFThe sensitive spectroscopic technique noise-immune cavity-enhanced optical heterodyne molecular spectroscopy (NICE-OHMS) has been successfully used in a variety of systems; however, no broadly tunable setup has been developed for the mid-infrared. To this end, we have integrated a difference frequency generation system into a NICE-OHMS setup. Initial optimization and characterization was completed with ro-vibrational spectroscopy of methane.
View Article and Find Full Text PDFDirect spectroscopy of a fast molecular ion beam offers many advantages over competing techniques, including the generality of the approach to any molecular ion, the complete elimination of spectral confusion due to neutral molecules, and the mass identification of individual spectral lines. The major challenge is the intrinsic weakness of absorption or dispersion signals resulting from the relatively low number density of ions in the beam. Direct spectroscopy of an ion beam was pioneered by Saykally and co-workers in the late 1980s, but has not been attempted since that time.
View Article and Find Full Text PDFThe novel technique of cavity enhanced velocity modulation spectroscopy has recently been demonstrated as the first general absorption technique that allows for sub-Doppler spectroscopy of molecular ions while retaining ion-neutral discrimination. The previous experimental setup has been further improved with the addition of heterodyne detection in a NICE-OHMS setup. This improves the sensitivity by a factor of 50 while retaining sub-Doppler resolution and ion-neutral discrimination.
View Article and Find Full Text PDFThe spectroscopic study of molecular ions is of great importance to a variety of fields, but is challenging as ions are typically produced in plasmas containing many orders of magnitude more neutral molecules than ions. The successful technique of velocity modulation permits discrimination between ion and neutral absorption signals and has allowed the study of scores of molecular ions in the past quarter century. However, this technique has long been considered to be inappropriate for use with cavity-enhanced techniques, owing to the directional nature of the velocity modulation.
View Article and Find Full Text PDF