J Opt Soc Am A Opt Image Sci Vis
December 2022
Astronomical instruments to detect exoplanets require extreme wavefront stability. For these missions to succeed, comprehensive and precise modeling is required to design and analyze suitable coronagraphs and their wavefront control systems. In this paper, we describe techniques for integrated modeling at scale that is, to the best of our knowledge, 1000 times faster than previously published works.
View Article and Find Full Text PDFUnlabelled: The objective of this study was to characterize magnetic resonance imaging (MRI) findings and correlate with clinical results in patients who underwent autologous chondrocyte implantation (ACI) of osteochondral lesions of the talus (OLT).
Methods: Twenty-four grafts were evaluated at a mean 65.8 months after ACI for OLT.
Am J Sports Med
September 2014
Background: The treatment of osteochondral lesions of the talus after failed surgery is challenging, with no clear solution. Short-term results using autologous chondrocyte implantation have been promising.
Purpose: To report the long-term outcomes of patients who underwent autologous chondrocyte implantation (ACI) of the talus after failed marrow stimulation techniques for osteochondral lesions of the talus (OLTs).
FYN kinase is highly expressed in the testis and has been implicated in testis and sperm function, yet specific roles for this kinase in testis somatic and germ cells have not been defined. The purpose of the present investigation was to identify aspects of spermatogenesis, spermiation, or sperm fertilizing capacity that required FYN for normal reproductive function. Matings between Fyn-null males and wild-type females resulted in normal litter sizes, despite the fact that Fyn-null males exhibited reduced epididymal size and sperm count.
View Article and Find Full Text PDFWhen conservative treatment is unsuccessful, there are many surgical options to treat patients with symptomatic chronic osteochondral lesions of the talus. The chosen treatment depends on the patient's symptoms, clinical examination findings, preoperative imaging results, and whether prior surgery was unsuccessful. It is important to be aware of treatment alternatives such as marrow stimulation, osteochondral autograft or allograft plugs, autologous chondrocyte implantation, and newer techniques currently being investigated outside the United States.
View Article and Find Full Text PDFAm J Orthop (Belle Mead NJ)
October 2009
To assess the impact of bone cement viscosity on total knee arthroplasty, we compared 1 high-viscosity and 2 medium-viscosity cements with respect to mantle area and zone-specific intrusion depths into the tibial plateau. We analyzed postoperative radiographs to determine penetration area and depth in 72 consecutive patients (79 knees) in whom DePuy II (n = 11), Endurance (n = 34), or Simplex-P (n = 34) cement was used. Penetration into the tibial plateau (anteroposterior zones 1-4) was significantly reduced with use of the high-viscosity DePuy II cement but did not differ significantly between the 2 medium-viscosity cements, Endurance and Simplex-P.
View Article and Find Full Text PDFImprogan, a chemical congener of cimetidine, is a highly effective non-opioid analgesic when injected into the CNS. Despite extensive characterization, neither the improgan receptor, nor a pharmacological antagonist of improgan has been previously described. Presently, the specific binding of [(3)H]cimetidine (3HCIM) in brain fractions was used to discover 4(5)-((4-iodobenzyl)thiomethyl)-1H-imidazole, which behaved in vivo as the first improgan antagonist.
View Article and Find Full Text PDFImprogan is a chemical congener of the H2 antagonist cimetidine which shows the profile of a highly effective analgesic when administered directly into the CNS. Although the improgan receptor is unknown, improgan activates analgesic pathways which are independent of opioids, but may utilize cannabinoid mechanisms. To discover selective, potent, improgan-like drugs, seven compounds chemically related to improgan were synthesized and tested for antinociceptive activity in rats after intracerebroventricular (icv) administration.
View Article and Find Full Text PDFWe present an improved technique for imaging through turbulence at visible wavelengths using a rotation shearing pupil-plane interferometer, intended for astronomical and terrestrial imaging applications. While previous astronomical rotation shearing interferometers have made only visibility modulus measurements, this interferometer makes four simultaneous measurements on each interferometric baseline, with phase differences of pi/2 between each measurement, allowing complex visibility measurements (modulus and phase) across the entire input pupil in a single exposure. This technique offers excellent wavefront resolution, allowing operation at visible wavelengths on large apertures, is potentially immune to amplitude fluctuations (scintillation), and may offer superior calibration capabilities to other imaging techniques.
View Article and Find Full Text PDF