New-onset left bundle branch block (NLBBB) is the most common complication after transcatheter aortic valve implantation (TAVI). Expert consensus recommends temporary transvenous pacemaker (TTVP) support for 24 hours in these patients. To date, no study has examined TTVP use during the index hospitalization in detail.
View Article and Find Full Text PDFBackground: Given enough time, transcatheter heart valves (THVs) will degenerate and may require reintervention. Redo transcatheter aortic valve implantation (TAVI) is an attractive strategy but carries a risk of coronary obstruction.
Aims: We sought to predict how many TAVIs patients could undergo in their lifetime using computed tomography (CT) simulation.
Purpose: Nickel-titanium (nitinol) alloys possess a special set of properties that allow for a wide range of applications. Specifically, the transformation temperature for self-expanding nitinol peripheral stents allows for easy crimping at or below room temperature and reformation at body temperature becoming superelastic.
Case Report: We report the case of an elderly man with iliac stenting 1 month prior, who presented several weeks after recovering from coronavirus disease 2019 with recurrent anterior-wall ST-elevation myocardial infarction.
The occurrence of venous thromboembolisms in patients with COVID-19 has been established. We sought to evaluate the clinical impact of thrombosis in patients with COVID-19 over the span of the pandemic to date. We analyzed patients with COVID-19 with a diagnosis of thrombosis who presented to the MedStar Health system (11 hospitals in Washington, District of Columbia, and Maryland) during the pandemic (March 1, 2020, to March 31, 2021).
View Article and Find Full Text PDFBackground: We aimed to determine left ventricular outflow tract (LVOT) calcification impact following transcatheter aortic valve replacement (TAVR) with contemporary transcatheter heart valves. Recent studies reported a higher rate of 2-year mortality with greater than moderate LVOT calcium, but they have not established a reliable and validated method to assess the degree of valve calcification and utilized first-generation valves for their analyses.
Materials/methods: We conducted a retrospective analysis of patients who underwent TAVR at our institution from 2013 through 2017 with available valves.
Catheter Cardiovasc Interv
February 2022
Objectives: We sought to report details of the incidence, organisms, clinical course, and outcomes of prosthetic valve endocarditis (PVE) after transcatheter aortic valve replacement (TAVR) in low-risk patients.
Background: PVE remains a rare but devastating complication of aortic valve replacement. Data regarding PVE after TAVR in low-risk patients are lacking.
Objectives: To analyze post-marketing surveillance data from the United States Food and Drug Administration (FDA) Manufacturer and User Facility Device Experience (MAUDE) database for the VASCADE Vascular Closure System (Cardiva Medical Inc., Santa Clara, CA).
Background: The VASCADE Vascular Closure System is a closure device for femoral arterial and venous access-site closure that was approved by the FDA in 2013.
Cardiac involvement in coronavirus disease 2019 (COVID-19) has been established. This is manifested by troponin elevation and associated with worse patient prognosis. We evaluated whether patient outcomes improved as experience accumulated during the pandemic.
View Article and Find Full Text PDFTranscatheter aortic valve replacement (TAVR) is approved for all patient risk profiles and is an option for all patients irrespective of age. However, patients enrolled in the low- and intermediate-risk trials were in their 70s, and those in the high-risk trials were in their 80s. TAVR has never been systematically tested in young (<65 years), low-risk patients.
View Article and Find Full Text PDFEnd-stage liver disease (ESLD) is increasingly prevalent and shares many risk factors with coronary artery disease (CAD). No specific guidelines exist for pre-liver transplant evaluation of CAD, and pretransplant cardiovascular testing varies widely. The aim of this study is to characterize pre-transplant cardiac testing practices with post-transplant clinical outcomes.
View Article and Find Full Text PDFBackground: Recent meta-analyses have raised concerns about mortality with paclitaxel drug-coated balloons (DCB). This pooled, patient-level analysis of the BIOLUX P-I, P-II, and P-III studies was performed to evaluate the safety and efficacy of Passeo-18 Lux DCB.
Materials And Methods: Individual patient-level demographic, clinical, diagnostic, and procedural data from the BIOLUX P-I, BIOLUX P-II, and BIOLUX P-III studies were pooled in a common database.
Background: Cardiac involvement in coronavirus disease 2019 (COVID-19) is known, manifested by troponin elevation, and these patients have a worse prognosis than patients without myocardial injury.
Methods: We analyzed COVID-19-positive patients who presented to the MedStar Health system (11 hospitals in Washington, DC, and Maryland) during the pandemic (March 1-September 30, 2020). We compared renal function and subsequent in-hospital clinical outcomes based on the presence or absence of troponin elevation.
Background: Prospective bicuspid low-risk transcatheter aortic valve replacement (TAVR) registries' data demonstrated encouraging short-term results. Detailed data on transcatheter heart valve (THV) geometry after deployment using contemporary devices are lacking. This study sought to examine valve geometry after TAVR in patients with bicuspid aortic stenosis (AS).
View Article and Find Full Text PDFCardiovasc Revasc Med
December 2021
Background: Cardiac involvement in coronavirus disease 2019 (COVID-19) is known, manifested by troponin elevation. Studies in the initial phase of the pandemic demonstrated that these patients tended to have a worse prognosis than patients without myocardial injury. We sought to evaluate the clinical impact of significant troponin elevation in COVID-19-positive patients, along with predictors of poor outcomes, over the span of the pandemic to date.
View Article and Find Full Text PDFThe prognosis of left circumflex (LC) versus non-LC in-stent restenosis (ISR) ostial lesions following treatment has not been assessed. We aimed to assess this prognosis. Anecdotally, treatment of ostial LC ISR has been associated with high recurrence rates.
View Article and Find Full Text PDFBackground: To date, there are no real-world studies comparing cangrelor to glycoprotein IIb/IIIa inhibitors (GPI) during percutaneous coronary intervention (PCI). Thus, we performed this study to evaluate the safety and effectiveness of cangrelor compared to GPI during PCI.
Methods: We identified patients who underwent PCI at our institution who received either cangrelor or GPI during PCI.
The rationale for dual antiplatelet therapy (DAPT) after transcatheter aortic valve implantation (TAVI) is to facilitate endothelialization of metallic struts of the transcatheter heart valve and to prevent thrombosis that could lead to thromboembolic events. Based on expert consensus, current societal guidelines recommend DAPT for 1 to 6 months after TAVI with weak evidence. Although the pivotal TAVI trials mandated this regimen, the evidence for the efficacy of DAPT to prevent transcatheter heart valve thrombosis is limited to 3 small trials and a handful of observational studies.
View Article and Find Full Text PDFDespite an expanding armamentarium of devices, many patients with mitral regurgitation referred for transcatheter mitral valve repair (TMVr) or replacement (TMVR) do not meet strict clinical trial inclusion and exclusion criteria. We sought to understand the rates that patients were excluded from transcatheter mitral valve therapies and reasons why. We retrospectively analyzed the medical charts and correspondence related to patients referred to our tertiary valve center for TMVr or TMVR between June 2016 and September 2019.
View Article and Find Full Text PDFBackground: Myocarditis is a highly morbid complication of immune checkpoint inhibitor (ICI) use that remains inadequately characterized. The QRS duration and the QTc interval are standardized electrocardiographic measures that are prolonged in other cardiac conditions; however, there are no data on their utility in ICI myocarditis.
Methods: From an international registry, ECG parameters were compared between 140 myocarditis cases and 179 controls across multiple time points (pre-ICI, on ICI prior to myocarditis, and at the time of myocarditis).
Transcatheter mitral valve replacement (TMVR) is a therapeutic option for patients with severe mitral disease who are deemed inoperable due to their overall surgical risk. The close relationships between the left ventricular outflow tract (LVOT) and the anterior mitral valve leaflet can lead to LVOT obstruction, a common complication with high mortality. Predicting and preventing LVOT obstruction is therefore essential, prior to TMVR.
View Article and Find Full Text PDFObjectives: We analyzed post-marketing surveillance data from the United States Food and Drug Administration (FDA) Manufacturer and User Facility Device Experience (MAUDE) database for suture-based vascular closure devices (VCDs) - Perclose ProGlide (Abbott, Chicago, Illinois) and Prostar XL (Abbott).
Background: Suture-based VCDs are mostly used for large-bore femoral arterial access-site closure. Real-world, contemporary experience on the most commonly reported complications and modes of failure associated with these devices is limited.