Publications by authors named "Brian Fahey"

Objective: Incompetent perforator veins are encountered frequently during ultrasound assessment of the venous system in chronic venous disease. Some studies have shown that concomitant treatment of truncal and perforator incompetence improves ulcer healing, yet a Cochrane review was unable to determine the potential benefits of perforator surgery in venous ulcer management due to poor quality evidence. This study aims to establish the exact role of concomitant treatment in patients with chronic venous disease.

View Article and Find Full Text PDF

Background: Informed consent is an ethical and legal requirement in healthcare and supports patient autonomy to make informed choices about their own care. This review explores the impact of digital technology for informed consent in surgery.

Methods: A systematic search of EBSCOhost (MEDLINE/CINAHL), Embase, Cochrane Central Register of Controlled Trials and Web of Science was performed in November 2021.

View Article and Find Full Text PDF

Introduction: The incidence of failed endovascular (EVAR) and open repair (OR) is increasing. Redo aortic repair is required in 10% of patients. Extension of the proximal sealing zone above the visceral arteries to adequate, healthier thoracic aorta using a fenestrated graft (FEVAR) can rescue a failing repair.

View Article and Find Full Text PDF

Introduction: The combination of the LUCAS 2 (L-CPR) automated CPR device and an impedance threshold device (ITD) has been widely implemented in the clinical field. This animal study tested the hypothesis that the addition of an ITD on L-CPR would enhance cerebral and coronary perfusion pressures.

Methods: Ten female pigs (39.

View Article and Find Full Text PDF

Acoustic radiation force impulse (ARFI) imaging characterizes the mechanical properties of tissue by measuring displacement resulting from applied ultrasonic radiation force. In this paper, we describe the current status of ARFI imaging for lower-limb vascular applications and present results from both tissue-mimicking phantoms and in vivo experiments. Initial experiments were performed on vascular phantoms constructed with polyvinyl alcohol for basic evaluation of the modality.

View Article and Find Full Text PDF

The initial results from clinical trials investigating the utility of acoustic radiation force impulse (ARFI) imaging for use with radio-frequency ablation (RFA) procedures in the liver are presented. To date, data have been collected from 6 RFA procedures in 5 unique patients. Large displacement contrast was observed in ARFI images of both pre-ablation malignancies (mean 7.

View Article and Find Full Text PDF
Article Synopsis
  • - Intracardiac echocardiography (ICE) is an effective imaging tool for guiding cardiac procedures, like radiofrequency ablation (RFA), but traditional ultrasound struggles to assess lesion size accurately.
  • - Acoustic radiation force impulse (ARFI) imaging offers improved visualization of variations in tissue stiffness, allowing for clearer identification of lesions created during RFAs.
  • - The study demonstrated that ARFI imaging with an ICE probe can produce high-quality images that reveal the boundaries of lesions, facilitating better monitoring during cardiac ablations, unlike conventional B-mode imaging which was less effective.
View Article and Find Full Text PDF

With the advent of real-time Acoustic Radiation Force Impulse (ARFI) imaging, elevated frame rates are both desirable and relevant from a clinical perspective. However, fundamental limitations on frame rates are imposed by thermal safety concerns related to incident radiation force pulses. Abdominal ARFI imaging utilizes a curvilinear scanning geometry that results in markedly different tissue heating patterns than those previously studied for linear arrays or mechanically-translated concave transducers.

View Article and Find Full Text PDF

The effect of physiological motion on the quality of radiation force elasticity images has been investigated. Experimental studies and simulated images were used to investigate the impact of motion effects on image quality metrics over a range of clinically realistic velocity and acceleration magnitudes. Evaluation criteria included motion filter effectiveness, image signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR) of a stiff inclusion embedded in a homogeneous background material.

View Article and Find Full Text PDF

The feasibility of utilizing acoustic radiation force impulse (ARFI) imaging to assess the mechanical properties of abdominal tissues was investigated. The thermal safety of the technique was also evaluated through the use of finite element method models. ARFI imaging was shown to be capable of imaging abdominal tissues at clinically realistic depths.

View Article and Find Full Text PDF

Acoustic radiation force impulse (ARFI) imaging techniques were used to monitor radiofrequency (RF) ablation of ovine cardiac tissue in vivo. Additionally, ARFI M-mode imaging methods were used to interrogate both healthy and ablated regions of myocardial tissue. Although induced cardiac lesions were not visualized well in conventional B-mode images, ARFI images of ablation procedures allowed determination of lesion location, shape, and relative size through time.

View Article and Find Full Text PDF

The ability of acoustic radiation force impulse (ARFI) imaging to visualize thermally- and chemically-induced lesions in soft tissues was investigated. Lesions were induced in freshly excised bovine liver samples. Chemical lesions were induced via the injection of formaldehyde and thermal lesions were created using a radiofrequency (RF) ablation system.

View Article and Find Full Text PDF