Publications by authors named "Brian C Aros"

Objective: To use a cadaver model to evaluate an all-inside meniscal repair device (MaxFire).

Methods: Six fresh-frozen cadaveric knees (ages 30-84 years) without evidence of prior surgery were used for this study. The knees were rigidly mounted and arthroscopy performed using standard anteromedial and anterolateral portals.

View Article and Find Full Text PDF

We report the load to failure in tensile testing of the MaxFire™ meniscal repair system (Biomet Inc, Warsaw, IN) and compare it to other current meniscal repair devices and mattress suture techniques. After creating a longitudinal tear in 42 one-year-old bovine menisci, 7 specimen groups defined by the meniscal repair device, suture, and/or mattress technique used for meniscal repair were randomly established: (Group 1: Fiberwire™ vertical mattress (VM), Group 2: Fiberwire™ horizontal mattress (HM), Group 3: FasT-Fix™ VM, Group 4: FasT-Fix™ HM, Group 5: RapidLoc™, Group 6: MaxFire™ VM, Group 7: MaxFire™ HM). After completing the repairs, the meniscal specimens were cyclically pre-loaded before load to failure testing was performed.

View Article and Find Full Text PDF