Publications by authors named "Brent Eaton"

X-ray free-electron lasers (XFELs) provide very intense X-ray pulses suitable for macromolecular crystallography. Each X-ray pulse typically lasts for tens of femtoseconds and the interval between pulses is many orders of magnitude longer. Here we describe two novel acoustic injection systems that use focused sound waves to eject picoliter to nanoliter crystal-containing droplets out of microplates and into the X-ray pulse from which diffraction data are collected.

View Article and Find Full Text PDF

Acoustic liquid handling uses high-frequency acoustic signals that are focused on the surface of a fluid to eject droplets with high accuracy and precision for various life science applications. Here we present a multiwell source plate, the Echo Qualified Reservoir (ER), which can acoustically transfer over 2.5 mL of fluid per well in 25-nL increments using an Echo 525 liquid handler.

View Article and Find Full Text PDF

Purpose: To investigate the source of native low-frequency fluctuations (LFF) in functional MRI (fMRI) signal.

Materials And Methods: Phase analysis was performed on tissue-segmented fMRI data acquired at systematically varying sampling rates.

Results: LFF in fMRI signal were both native and aliased in origin.

View Article and Find Full Text PDF

We report the development of an interactive approach to single-word language production studies in fMRI. The approach, adaptive pacing, involves real-time adjustment of stimulus presentation times based on individual subject performance timing and content. At the same time, it maintains a stochastic distribution of interstimulus intervals to avoid confounding task covariates with speech-related signal variance.

View Article and Find Full Text PDF

Model quality is rarely assessed in fMRI data analyses and less often reported. This may have contributed to several shortcomings in the current fMRI data analyses, including: (1) Model mis-specification, leading to incorrect inference about the activation-maps, SPM[t] and SPM[F]; (2) Improper model selection based on the number of activated voxels, rather than on model quality; (3) Under-utilization of systematic model building, resulting in the common but suboptimal practice of using only a single, pre-specified, usually over-simplified model; (4) Spatially homogenous modeling, neglecting the spatial heterogeneity of fMRI signal fluctuations; and (5) Lack of standards for formal model comparison, contributing to the high variability of fMRI results across studies and centers. To overcome these shortcomings, it is essential to assess and report the quality of the models used in the analysis.

View Article and Find Full Text PDF