Publications by authors named "Brendan Chou"

To determine whether the cause of cardiomyopathy affects outcomes in patients who undergo continuous-flow left ventricular assist device support, we compared postimplant adverse events and survival between patients with ischemic and nonischemic cardiomyopathy. The inclusion criteria for the ischemic group were a history of myocardial infarction or revascularization (coronary artery bypass grafting or percutaneous coronary intervention), ≥75% stenosis of the left main or proximal left anterior descending coronary artery, or ≥75% stenosis of ≥2 epicardial vessels. From November 2003 through March 2016, 526 patients underwent device support: 256 (48.

View Article and Find Full Text PDF

Objective: Risk-scoring systems for surgical aortic valve replacement (AVR) were largely derived from sternotomy cases. We evaluated the accuracy of current risk scores in predicting outcomes after minimally invasive AVR (mini-AVR). Because transcatheter AVR (TAVR) is being considered for use in low-risk patients with aortic stenosis, accurate mini-AVR risk assessment is necessary.

View Article and Find Full Text PDF

Objectives: Some patients who undergo continuous-flow left ventricular assist device (CF-LVAD) implantation require concomitant procedures that can be performed with or without cardiac arrest under aortic cross-clamping (AXC). Procedures normally performed with cardiac arrest are sometimes avoided or performed without cardiac arrest because it may be detrimental to right heart function. However, the effects of cardiac arrest on patients with advanced heart failure necessitating CF-LVAD support have not been thoroughly studied.

View Article and Find Full Text PDF

Background: Despite technological advancements, pump durability and pump-related complications continue to affect and adversely impact the lives of patients with end-stage heart failure on left ventricular assist device (LVAD) support. In an attempt to avoid recurrent LVAD-related complications, there may be circumstances where it is clinically advantageous to exchange a patient's device from HeartMate II to HeartWare HVAD. However, there is a paucity of data that describes the safety and feasibility of such an approach.

View Article and Find Full Text PDF

Implantable continuous-flow left ventricular assist devices (CF-LVADs) are used for long-term LV support in bridging patients to heart transplantation or as destination therapy. With prolonged support times, some patients will have repeat complications necessitating multiple device exchanges. To elucidate the safety and efficacy of repeat device exchange, we retrospectively reviewed data from 25 patients who underwent two or more CF-LVAD implantations between July 2005 and August 2017.

View Article and Find Full Text PDF

Background: Public reporting of cardiac surgery ratings has been advocated to inform patient selection of hospitals. Although Society of Thoracic Surgeons (STS) ratings are based on audited risk-adjusted patient outcomes, other rating systems rely on administrative databases. In this study, we evaluate correlation among 4 widely used hospital rating systems for coronary artery bypass grafting (CABG) and aortic valve replacement (AVR).

View Article and Find Full Text PDF

Small noncoding RNAs (sRNAs) are posttranscriptional regulators that have been identified in multiple species and shown to play essential roles in responsive mechanisms to environmental stresses. The natural ability of specific bacteria to resist high levels of radiation has been of high interest to mechanistic studies of DNA repair and biomolecular protection. Deinococcus radiodurans is a model extremophile for radiation studies that can survive doses of ionizing radiation of >12,000 Gy, 3,000 times higher than for most vertebrates.

View Article and Find Full Text PDF

Interest in finding small RNAs (sRNAs) in bacteria has significantly increased in recent years due to their regulatory functions. Development of high-throughput methods and more sophisticated computational algorithms has allowed rapid identification of sRNA candidates in different species. However, given their various sizes (50 to 500 nucleotides [nt]) and their potential genomic locations in the 5' and 3' untranslated regions as well as in intergenic regions, identification and validation of true sRNAs have been challenging.

View Article and Find Full Text PDF

An elegant method for the electrodeposition of MoS2 thin films using room temperature ionic liquids (RTIL) as an electrolyte was developed. Simple molecular precursors of Mo and S were added in different concentrations to tune the composition and deposition process. The electrodeposition of MoS2 was confirmed with both Raman spectroscopy and XPS.

View Article and Find Full Text PDF

A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_session704nmom6f7lb1vh3v5g2k5nph33mgjcu): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once