Background: The 12-month follow-up (F/U) efficacy of CBA PVI performed at community hospitals for treatment of symptomatic paroxysmal and persistent atrial fibrillation (AF) is unknown. This study determined the 12-month efficacy of pulmonary vein isolation (PVI) using cryoballoon ablation (CBA) performed at community hospitals with limited annual case numbers.
Methods: This registry study included 983 consecutive patients (pts) from 19 hospitals, each with an annual procedural volume of < 100 PVI procedures/year.
Currently, the term "heart failure with preserved left ventricular ejection fraction (HFpEF)" is based on echocardiographic parameters and clinical symptoms combined with elevated or normal levels of natriuretic peptides. Thus, "HFpEF" as a diagnosis subsumes multiple pathophysiological entities making a uniform management plan for "HFpEF" impossible. Therefore, a more specific characterization of the underlying cardiac pathologies in patients with preserved ejection fraction and symptoms of heart failure is mandatory.
View Article and Find Full Text PDFThe goal of Level 1 training in echocardiography is to enable the trainee to select echocardiography appropriately for the evaluation of a specific clinical question, and then to interpret the report. It is not the goal of Level 1 training to teach how to perform the examination itself-that is the goal of higher levels of training. However, understanding the principles, indications, and findings of this crucial technique is valuable to many medical professionals including outside cardiology.
View Article and Find Full Text PDFFocus cardiac ultrasound (FoCUS) provides vital information at at the bedside which has the potential of improving outcomes in the acute settings. FoCUS could help the clinicians in their daily clinical decision-making while applied within the clinical context as an extension of bedside clinical examination. FoCUS practitioners should be aware of their own limitations with the importance of the timely referral for comprehensive Echocardiography whenever required.
View Article and Find Full Text PDFAims: Pulmonary vein isolation (PVI) using cryoballoon ablation (CBA) is an established procedure for treating symptomatic paroxysmal and persistent atrial fibrillation (AF). The safety and efficacy of PVI performed at community hospitals are unknown. We aimed to determine the safety and acute efficacy of PVI using CBA performed at community hospitals with limited annual case numbers.
View Article and Find Full Text PDFThe advantages of upgrade to cardiac resynchronisation therapy (CRT) have not been explored as carefully as the outcomes of de novo CRT implantations. Furthermore selection criteria for patients with the potential to benefit the most from this therapy are unknown. Therefore, we analyzed the long term outcome and its predictors in a real-world cohort receiving a CRT upgrade from previous pacemaker (PM) and defibrillator devices (ICD).
View Article and Find Full Text PDFPurpose: Cardiac disease frequently has a degenerative effect on cardiac pump function and regional myocardial contraction. Therefore, an accurate assessment of regional wall motion is a measure of the extent and severity of the disease. We sought to further validate an intra-operative, sensor-based technology for measuring wall motion and strain by characterizing left ventricular (LV) mechanical and electrical activation patterns in patients with normal (NSF) and impaired systolic function (ISF).
View Article and Find Full Text PDFAims: This randomized single-centre study sought to compare the efficacy and safety of pulmonary vein isolation (PVI) plus voltage-guided ablation vs. PVI with or without linear ablation depending on the type of atrial fibrillation (AF).
Methods And Results: Overall, 124 ablation-naive patients with paroxysmal or persistent AF were randomized to PVI with (persistent AF) or without (paroxysmal AF) additional linear ablation (control group) vs.
Herzschrittmacherther Elektrophysiol
June 2017
A 32-year-old, otherwise healthy woman was admitted after successful out-of-hospital resuscitation due to ventricular fibrillation. Established cardiac, pulmonary, metabolic, and toxicological causes were excluded. However, persisting (biphasic) negative T waves in the inferior ECG leads and premature ventricular contractions (PVC) were noted.
View Article and Find Full Text PDFAims: The association between anatomical left atrial (LA) remodelling and ventricular diastolic dysfunction (DD) in atrial fibrillation (AF) patients is not well studied. We aimed to examine the effect of DD on anatomic LA remodelling and their relation with ablation outcomes.
Methods And Results: In 104 patients (58 ± 10 years, 69% male) referred for AF ablation, LA volume (LAV) was determined by computed tomography.
Aims: In times of evolving cardiac resynchronization therapy, intra-procedural characterization of left ventricular (LV) mechanical activation patterns is desired but technically challenging with currently available technologies. In patients with normal systolic function, we evaluated the feasibility of characterizing LV wall motion using a novel sensor-based, real-time tracking technology.
Methods And Results: Ten patients underwent simultaneous motion and electrical mapping of the LV endocardium during sinus rhythm using electroanatomical mapping and navigational systems (EnSite™ NavX™ and MediGuide™, SJM).
Stress echocardiography (SE) is a powerful functional imaging technique to assess cardiac performance under work conditions. The main indication is the detection of myocardial ischemia due to coronary artery disease (CAD), however it can also be used in patients with structural heart disease (e. g.
View Article and Find Full Text PDFRadiofrequency (RF) ablation with irrigated tip catheters decreases the likelihood of thrombus and char formation and enables the creation of larger lesions. Due to the potential dramatic consequences, the prevention of thromboembolic events is of particular importance for left-sided procedures. Although acute success rates of ventricular tachycardia (VT) ablation are satisfactory, recurrence rate is high.
View Article and Find Full Text PDFAims: Proper management of post-interventional pain relieves unwarranted patient distress and enhances patient satisfaction. There have been only a limited number of investigations into patient discomfort following electrophysiological interventions. This study aims to quantify pain after interventional procedures, including ablation of atrial fibrillation (AF) or ventricular tachycardia (VT), as well as implant or explant of pacemakers or implantable cardioverter defibrillators.
View Article and Find Full Text PDFBackground: Radiofrequency catheter ablation is currently considered as the therapeutic option of choice in patients with arrhythmogenic right ventricular cardiomyopathy (ARVC) and recurrent ventricular tachycardia (VT).
Methods: This study intended to assess the long-term outcome of catheter ablation in patients with ARVC and electrical storm. The specific objective was to assess the relationship between precordial QRS amplitude ratio and outcome of catheter ablation in these patients.
Aims: Data comparing remote magnetic catheter navigation (RMN) to manual catheter navigation (MCN) using steerable sheath for ablation of atrial fibrillation (AF) is lacking. The aim of the present case-control study was to seek AF recurrence data after AF ablation using RMN in comparison to MCN using steerable sheath in patients with either paroxysmal or persistent AF.
Methods And Results: This study comprised 140 patients with AF (50% paroxysmal).
Background: The incidence of postoperative complications following pacemaker or implantable cardioverter-defibrillator implantations in patients treated with new oral anticoagulation agents has not been studied. Here we present a first comparison of complications after cardiac rhythm device (CRD) implantations in patients with atrial fibrillation (AF) treated with dabigatran or uninterrupted warfarin.
Methods And Results: Using a case-control study design, we compared complications within 30 days after 236 CRD procedures performed under uninterrupted warfarin (n=118) or interrupted dabigatran (n=118).
Introduction: Implantation of cardiac resynchronization therapy (CRT) devices can be challenging, time consuming, and fluoroscopy intense. To facilitate placement of left ventricular (LV) leads, a novel electromagnetic navigation system (MediGuide™, St. Jude Medical, St.
View Article and Find Full Text PDFBackground:The incidence of postoperative complications following pacemaker or implantable cardioverter-defibrillator implantations in patients treated with new oral anticoagulation agents has not been studied. Here we present a first comparison of complications after cardiac rhythm device (CRD) implantations in patients with atrial fibrillation (AF) treated with dabigatran or uninterrupted warfarin.Methods and Results:Using a case-control study design, we compared complications within 30 days after 236 CRD procedures performed under uninterrupted warfarin (n=118) or interrupted dabigatran (n=118).
View Article and Find Full Text PDFBackground And Purpose: Approximately 20-25% of the patients with hypertrophic cardiomyopathy (HCM) develop atrial fibrillation (AF) during the clinical course of the disease, a percentage significantly larger than that of the general population. The purpose of the present study was to report on the procedural results of patients with AF and either primary or secondary left ventricular hypertrophy (LVH).
Methods And Subjects: Twenty-two consecutive HCM patients (55% male, mean age 57±8 years) with symptomatic AF, having undergone AF ablation procedures between September 2009 and July 2012 were compared with respect to procedural outcome and follow-up characteristics with 22 matched controls with secondary cardiac hypertrophy (64% male, 63±10 years) from our prospective AF catheter ablation registry.