Publications by authors named "Bream P"

Article Synopsis
  • The study focuses on improving vascular access for patients needing frequent apheresis by transitioning from a Vortex dual lumen port to a combination of a Powerflow port and a ClearVUE port.
  • Results showed that the new port configuration significantly reduced treatment time (from 91.18 min to 77.96 min) and increased flow rates (from 61.59 mL/min to 71.89 mL/min).
  • Additionally, the need for tissue plasminogen activator (tPA) was almost eliminated among those switched from the Vortex ports, indicating potential cost savings and improved efficiency in apheresis procedures.
View Article and Find Full Text PDF

Rationale And Objective: This study aimed to develop a cosmesis scale to evaluate the cosmetic appearance of hemodialysis (HD) arteriovenous (AV) accesses from the perspective of the patient and clinician, which could be incorporated into clinical trials.

Study Design: Using a modified Delphi process, two AV access cosmesis scale (AVACS) components were developed in a four-round Delphi panel consisting of two surveys and two consensus meetings with two rounds of patient consultation.

Setting And Participants: The Delphi panel consisted of 15 voting members including five interventional or general nephrologists, five vascular surgeons, three interventional radiologists, and two vascular access nurse coordinators.

View Article and Find Full Text PDF

Purpose: To investigate the safety and efficacy of attaching a weighted extension to the distal aspect of prefabricated gastrojejunostomy (GJ) tubes, and to determine whether this alteration reduces the occurrences of tip reflux into the esophagus or stomach.

Materials And Methods: This retrospective 1-way crossover study included 64 GJ tubes in 15 patients placed by multiple operators in the interventional radiology department at a single institution from July 1, 2019, to December 1, 2021. Patients were selected for a weighted tip extension if they required a GJ tube exchange because of the distal tip refluxing into the stomach or esophagus and were aged ≥18 years.

View Article and Find Full Text PDF

Pocket infections are an occasional complication of totally implanted central venous catheters. The purpose of this study was to compare the safety, efficacy, and efficiency of the use of hydrogel after port removal vs the conventional method of packed iodoform gauze. In a cohort of 31 patients, the hydrogel group (n = 13) healed significantly faster than the group treated with the conventional method (15.

View Article and Find Full Text PDF

Background: Central venous ports placed for breast cancer treatment have traditionally been placed contralateral to the disease. This is done out of concern for the possibility of an increased risk of complications with ipsilateral port placement. There have been only a few small studies evaluating complication rates between ports placed ipsilateral versus contralateral to the breast cancer.

View Article and Find Full Text PDF
Article Synopsis
  • Different techniques exist for placing gastrostomy tubes, with radiologic-guided placement depending on imaging for accuracy and safety.
  • A comprehensive understanding of immediate and delayed risks associated with the procedure is crucial for healthcare providers.
  • The article discusses potential complications, offering recognition, prevention, and treatment strategies, supplemented by clinical examples.
View Article and Find Full Text PDF

Introduction: Red blood cell exchange (RCE) procedures are commonly used for stroke prevention in sickle cell disease (SCD) patients. We compared two different dual lumen ports used for RCE because differences between the port and catheter design may lead to functional variance.

Methods: We reviewed the RCE parameters of SCD patients following implantable port placement encountered at a single institution.

View Article and Find Full Text PDF

Introduction: The formation of integrated interventional radiology (IR) residency programs has changed the training paradigm. This change mandates the need to provide adequate exposure to allow students to explore IR as a career option and to allow programs to sufficiently evaluate students. This study aims to highlight the availability of medical student education in IR and proposes a basic framework for clinical rotations.

View Article and Find Full Text PDF

The use of social media among interventional radiologists is increasing, with Twitter receiving the most attention. Twitter is an ideal forum for open exchange of ideas from around the world. However, it is important for Twitter users to gain a rudimentary understanding of the many potential communication pathways to connect with other users.

View Article and Find Full Text PDF

Central venous catheters are a popular choice for the initiation of hemodialysis or for bridging between different types of access. Despite this, they have many drawbacks including a high morbidity from thrombosis and infection. Advances in technology have allowed placement of these lines relatively safely, and national guidelines have been established to help prevent complications.

View Article and Find Full Text PDF

We are currently in the midst of a worldwide obesity epidemic, including in patients with end-stage kidney disease. Placing hemodialysis catheters is a particular challenge in patients with extreme obesity. Here we describe the merging of two technologies to place catheters in patients who are too heavy (over 225 kg) to be placed safely on a procedure table for fluoroscopic guidance.

View Article and Find Full Text PDF

Background: The hemodialysis reliable outflow (HeRO) access device is a permanent dialysis graft used in patients with central venous obstruction. Given the complexity of care related to end-stage dialysis access (ESDA) patients, a multidisciplinary approach has been used to achieve operative success of HeRO graft placement.

Methods: The single-center retrospective review included adult patients that were seen in ESDA clinic who underwent a HeRO graft placement from September 2010-September 2014 under the care of a team consisting of a nephrologist, an interventional radiologist, and a surgeon.

View Article and Find Full Text PDF

Thrombosis is the leading cause of arteriovenous (AV) access failure for hemodialysis patients requiring frequent interventions. We describe a novel approach to the lyse-and-wait technique in thrombosed AV access using nurse-administered thrombolytics in a hospital-based hemodialysis unit. All patients at a single-center, large, urban, tertiary care hospital, who underwent in-center thrombolysis via alteplase instilled directly into a thrombosed AV access by inpatient hemodialysis unit staff between January 1, 2003 and December 31, 2007, were eligible.

View Article and Find Full Text PDF

Background: The Hemodialysis Reliable Outflow (HeRO) dialysis access device is a permanent tunneled dialysis graft connected to a central venous catheter and is used in patients with end-stage dialysis access (ESDA) issues secondary to central venous stenosis. The safety and effectiveness of the HeRO device has previously been proven, but no study thus far has compared the cost of its use with tunneled dialysis catheters (TDCs) and thigh grafts in patients with ESDA.

Materials And Methods: A decision analytic model was developed to simulate outcomes for patients with ESDA undergoing placement of a HeRO dialysis access device, TDC, or thigh graft.

View Article and Find Full Text PDF

Mediastinal fibrosis can present with a multitude of symptoms, most commonly cough, dyspnea and hemoptysis. We describe a case of mediastinal fibrosis secondary to histoplasmosis, which presented with both superior vena cava syndrome (SVCS) and hemoptysis. Our patient was successfully treated with bronchial artery embolization followed by SVC stent placement during a brief hospital stay.

View Article and Find Full Text PDF

A Günther Tulip retrievable inferior vena cava filter was placed in a 9-year-old boy with T-cell ALL who had both iliofemoral deep vein thrombosis (DVT) and acute intracranial hemorrhage. The filter was removed 147 days after placement, when the patient was no longer at increased risk for DVT or pulmonary embolus. Removal of the filter did not compromise flow through the vena cava.

View Article and Find Full Text PDF

Portal vein embolization is evolving as an important adjunctive tool in hepatic surgery. In select patients, preoperative hypertrophy of the future remnant liver via contralateral portal vein embolization decreases postoperative liver dysfunction. Hepatic steatosis is the most common liver parenchymal disorder in Western populations.

View Article and Find Full Text PDF