This paper presents an approach to apply aquatic passive sampling (PS) in regulatory chemical water quality monitoring in Europe. Absorption-based passive sampling is well developed and suitable for the sampling of hydrophobic chemicals, some of which are European Water Framework Directive priority substances with Environmental Quality Standards (EQS) derived for biota. Considering a chemical activity approach to chemical risk assessment, we propose equilibrium concentration in lipids (from passive water sampling) as a reference value for measured concentrations in biota.
View Article and Find Full Text PDFPolycyclic aromatic hydrocarbons (PAHs), released from petrogenic, pyrogenic or diagenetic sources (degradation of wood materials), are of global concern due to their adverse effects, and potential for long-range transport. While dissolved PAHs have been frequently reported in the literature, there has been no consistent approach of sampling across water bodies. Passive samplers from the AQUA/GAPS-MONET initiative were deployed at 46 sites (28 marine and 18 freshwater), and analyzed for 28 PAHs and six polycyclic musks (PCMs) centrally.
View Article and Find Full Text PDFThis review examines the environmental occurrence and fate of aromatic amines (AAs), a group of environmental contaminants with possible carcinogenic and mutagenic effects. AAs are known to be partially responsible for the genotoxic traits of industrial wastewater (WW), and AA antioxidants are acutely toxic to some aquatic organisms. Still, there are gaps in the available data on sources, occurrence, transport, and fate in domestic WW and indoor environments, which complicate the prevention of adverse effects in aquatic ecosystems.
View Article and Find Full Text PDFAromatic amines (AAs) are human-made compounds known for their mutagenic properties, entering surface waters from various sources, often originating as transformation products of dyes or pesticides. Despite their low concentrations in surface waters, AAs can exhibit mutagenicity. Our study focused on evaluating three passive samplers (PSs) for enriching these compounds from influent and effluent of a wastewater treatment plant (WWTP) in Brno, Czech Republic.
View Article and Find Full Text PDFThe quality of chemical analysis is an important aspect of passive sampling-based environmental assessments. The present study reports on a proficiency testing program for the chemical analysis of hydrophobic organic compounds in silicone and low-density polyethylene (LDPE) passive samplers and hydrophilic compounds in polar organic chemical integrative samplers. The median between-laboratory coefficients of variation (CVs) of hydrophobic compound concentrations in the polymer phase were 33% (silicone) and 38% (LDPE), similar to the CVs obtained in four earlier rounds of this program.
View Article and Find Full Text PDFInformation on the indoor environment as a source of exposure with potential adverse health effects is mostly limited to a few pollutant groups and indoor types. This study provides a comprehensive toxicological profile of chemical mixtures associated with dust from various types of indoor environments, namely cars, houses, prefabricated apartments, kindergartens, offices, public spaces, and schools. Organic extracts of two different polarities and bioaccessible extracts mimicking the gastrointestinal conditions were prepared from two different particle size fractions of dust.
View Article and Find Full Text PDFDiffusive hydrogel-based passive sampler (HPS) based on diffusive gradients in thin films (DGT) is designed for monitoring polar organic contaminants in the aquatic environment. DGT technique controls the compound's overall uptake rate by adding a hydrogel layer of known thickness, which minimizes the importance of the resistive water boundary layer in the compound uptake process. In this work, we investigated several factors which may influence the diffusion of a range of aquatic contaminants in 1.
View Article and Find Full Text PDFOver the past decades, several types of passive samplers have been developed and used to monitor polar organic compounds in aquatic environments. These samplers use different sorbents and barriers to control the uptake into the sampler, but their performance comparison is usually not well investigated. This study aimed to directly compare the performance of three samplers, i.
View Article and Find Full Text PDFThe possibilities of expanding a groundwater quality monitoring scheme by passive sampling using polar organic chemical integrative sampler (POCIS) comprising HLB sorbent as the receiving phase were explored. Passive sampling and grab sampling were carried out simultaneously in the regions with vulnerable groundwater resources in Slovakia, between 2013 and 2021. For 27 pesticides and degradation products detected both in POCIS and the grab samples, in situ sampling rates were calculated and statistically evaluated.
View Article and Find Full Text PDFMonitoring methodologies reflecting the long-term quality and contamination of surface waters are needed to obtain a representative picture of pollution and identify risk drivers. This study sets a baseline for characterizing chemical pollution in the Danube River using an innovative approach, combining continuous three-months use of passive sampling technology with comprehensive chemical (747 chemicals) and bioanalytical (seven in vitro bioassays) assessment during the Joint Danube Survey (JDS4). This is one of the world's largest investigative surface-water monitoring efforts in the longest river in the European Union, which water after riverbank filtration is broadly used for drinking water production.
View Article and Find Full Text PDFPersistent organic pollutants (POPs) are recognized as pollutants of global concern, but so far, information on the trends of legacy POPs in the waters of the world has been missing due to logistical, analytical, and financial reasons. Passive samplers have emerged as an attractive alternative to active water sampling methods as they accumulate POPs, represent time-weighted average concentrations, and can easily be shipped and deployed. As part of the AQUA-GAPS/MONET, passive samplers were deployed at 40 globally distributed sites between 2016 and 2020, for a total of 21 freshwater and 40 marine deployments.
View Article and Find Full Text PDFAs Europe's second longest river, the Danube is an important water source for drinking water and irrigation for many countries, before discharging into the Black Sea in the East. Per- and poly-fluoroalkyl substances (PFAS) have been observed over the last two decades in concentrations exceeding the European Union's drinking water guidelines for total sum of 20 select PFAS of 0.1 μg L.
View Article and Find Full Text PDFPersistent organic pollutants (POPs) are widely distributed along the world and their levels in surface waters may pose a risk to human health due to consumption of contaminated water or fish long-term exposure to contaminated water. The occurrence of polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs) and organochlorine pesticides (OCPs) in the Piedras river (Colombia) is a problem of serious concern since freshwater is conducted to a drinking water supply system that provides more than 3 million users. In this research, we deployed silicone rubber membranes as passive samplers in two sampling campaigns at seven sampling stations selected along the river, to assess sources and spatial variation of POPs.
View Article and Find Full Text PDFAn upscaled passive sampler variant (diffusive hydrogel-based passive sampler; HPS) based on diffusive gradients in thin films for polar organic compounds (o-DGT) with seven times higher surface area (22.7 cm) than a typical o-DGT sampler (3.14 cm) was tested in several field studies.
View Article and Find Full Text PDFMany semi-volatile organic compounds (SVOCs) accumulate in indoor dust, which serves as a repository for those compounds. The presence of SVOCs in indoor environments is of concern because many of them are suspected to have toxic effects. Total SVOC concentrations in the dust are generally used for exposure assessment to indoor contaminants, assuming that 100% of the SVOCs is accessible for human uptake.
View Article and Find Full Text PDFHexachlorobenzene (HCB), listed on the Stockholm Convention on persistent organic pollutants and regulated as a hazardous priority pollutant by the Water Framework Directive (WFD), is ubiquitously distributed in the environment and assumed to mildly biomagnify in aquatic foodwebs. The proposal to include trophic magnification factors (TMFs) in the procedure for comparing contaminant levels in biota at different trophic levels (TLs) with WFD environmental quality standards requires adequate selection of TMFs. In the first step of our study, we compared two independently obtained datasets of pentachlorobenzene (PeCB) and HCB concentration ratios from passive sampling (PS) in water and in fish through routine monitoring programs in Norway to evaluate possible biomagnification.
View Article and Find Full Text PDFContamination with hydrophobic organic compounds (HOCs) such as persistent organic pollutants negatively affects global water quality. Accurate and globally comparable monitoring data are required to understand better the HOCs distribution and environmental fate. We present the first results of a proof-of-concept global monitoring campaign, the Aquatic Global Passive Sampling initiative (AQUA-GAPS), performed between 2016 and 2020, for assessing trends of freely dissolved HOC concentrations in global surface waters.
View Article and Find Full Text PDFContamination of aquatic ecosystems by hydrophobic organic contaminants (HOCs) is often assessed based on their concentrations in riverbed sediment and suspended particulate matter (SPM). However, total HOC concentration (C) in sediment or SPM is of limited value for evaluating the exposure of benthic or pelagic organisms. The accessible HOC concentration (C) presents a useful parameter quantifying the overall pool of HOC in sediment or SPM available for fast partitioning to the water phase or biota.
View Article and Find Full Text PDFNon-target analysis (NTA) employing high-resolution mass spectrometry is a commonly applied approach for the detection of novel chemicals of emerging concern in complex environmental samples. NTA typically results in large and information-rich datasets that require computer aided (ideally automated) strategies for their processing and interpretation. Such strategies do however raise the challenge of reproducibility between and within different processing workflows.
View Article and Find Full Text PDFMapping of hydrophobic organic compounds (HOCs) in surface seawater on an east-to-west transect of the South Atlantic Ocean (SAO) and across the Black Sea (BS) in 2016 was performed by a dynamic passive sampling device containing silicone-based passive samplers. In SAO as well as in BS the measurements confirmed freely dissolved concentrations of polychlorinated biphenyls, DDT and its metabolites, chlorobenzenes, cyclodiene pesticides, and brominated flame retardants in the range of units to low hundreds of pg per litre. The findings indicate that the spatial distribution of HOCs and emerging pollutants in the SAO and the BS is influenced by riverine inputs, ocean currents and atmospheric deposition from continental plumes.
View Article and Find Full Text PDFSemivolatile organic compounds (SVOCs) are mostly man-made chemicals that distribute between the gas and solid phase in the environment. Many of them could pose harm to people and therefore it is important to know their concentrations in the indoor environment to evaluate the related risks. Inhalation exposure can be assessed using passive sampling.
View Article and Find Full Text PDFPOCIS is the most widely applied passive sampler of polar organic substances, because it was one of the first commercially available samplers for that purpose on the market, but also for its applicability for a wide range of substances and conditions. Its main weakness is the variability of sampling performance with exposure conditions. In our study we took a pragmatic approach and performed in situ calibration for a set of 76 pharmaceuticals and their metabolites in five sampling campaigns in surface water, covering various temperature and flow conditions.
View Article and Find Full Text PDFTotal concentrations of hydrophobic organic contaminants (HOCs) in sediment present a poor quality assessment parameter for aquatic organism exposure and environmental risk because they do not reflect contaminant bioavailability. The bioavailability issue of HOCs in sediments can be addressed by application of multi-ratio equilibrium passive sampling (EPS). In this study, riverbed sediment samples were collected during the Joint Danube Survey at 9 locations along the Danube River in 2013.
View Article and Find Full Text PDF