Xylazine has emerged in recent years as a dangerous adulterant in illicit fentanyl use, and methods for the detection of xylazine in toxicology panels are still lagging. We developed methods for the screening and quantitation of xylazine in oral fluid (OF), a popular testing medium due to its ease of collection and reflection of presence in blood for many classes of drugs. Enzyme-linked immunosorbent assays were employed for the rapid screening of xylazine directly from the collection device buffer with a cutoff of 1 ng/mL.
View Article and Find Full Text PDFThe standard protocol in addiction treatment/pain management is to conduct immunoassay screens for major drugs subject to misuse, followed by confirmatory testing of positive results. However, this may miss unscreened or rarely screened drugs that could pose risks, especially to polydrug users. We sought to determine the prevalences of unscreened/rarely screened drugs in a sample of individuals misusing drugs in 7 U.
View Article and Find Full Text PDFBackground: The aims are to compare the results of presumptive drug testing with confirmation of positives vs. direct-to-definitive drug testing, combined with investigation of urine vs. oral fluid as test matrices.
View Article and Find Full Text PDF