Publications by authors named "Bram W Wisse"

Background: Alternative data sources for surveillance have gained importance in maintaining coronavirus disease 2019 (COVID-19) situational awareness as nationwide testing has drastically decreased. Therefore, we explored whether rates of sick-leave from work are associated with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) notification trends and at which lag, to indicate the usefulness of sick-leave data for COVID-19 surveillance.

Methods: We explored trends during the COVID-19 epidemic of weekly sick-leave rates and SARS-CoV-2 notification rates from 1 June 2020 to 10 April 2022.

View Article and Find Full Text PDF

In kidney transplantation, survival rates are still partly impaired due to the deleterious effects of donor specific HLA antibodies (DSA). However, not all luminex-defined DSA appear to be clinically relevant. Further analysis of DSA recognizing polymorphic amino acid configurations, called eplets or functional epitopes, might improve the discrimination between clinically relevant vs.

View Article and Find Full Text PDF

In kidney transplantation, donor HLA antibodies are a risk factor for graft loss. Accessibility of donor eplets for HLA antibodies is predicted by the ElliPro score. The clinical usefulness of those scores in relation to transplant outcome is unknown.

View Article and Find Full Text PDF

The clinical significance of non-HLA antibodies on renal allograft survival is a matter of debate, due to differences in reported results and lack of large-scale studies incorporating analysis of multiple non-HLA antibodies simultaneously. We developed a multiplex non-HLA antibody assay against 14 proteins highly expressed in the kidney. In this study, the presence of pretransplant non-HLA antibodies was correlated to renal allograft survival in a nationwide cohort of 4770 recipients transplanted between 1995 and 2006.

View Article and Find Full Text PDF

Whereas regular allocation avoids unacceptable mismatches on the donor organ, allocation to highly sensitized patients within the Eurotransplant Acceptable Mismatch (AM) program is based on the patient's HLA phenotype plus acceptable antigens. These are HLA antigens to which the patient never made antibodies, as determined by extensive laboratory testing. AM patients have superior long-term graft survival compared with highly sensitized patients in regular allocation.

View Article and Find Full Text PDF

The best treatment for patients with end-stage renal disease is kidney transplantation. Although graft survival rates have improved in the last decades, patients still may lose their grafts partly due to the detrimental effects of donor-specific antibodies (DSA) against human leukocyte antigens (HLA) and to a lesser extent also by antibodies directed against non-HLA antigens expressed on the donor endothelium. Assays to detect anti-HLA antibodies are already in use for many years and have been proven useful for transplant risk stratification.

View Article and Find Full Text PDF

Background: Few studies have evaluated the effect of different immunosuppressive strategies on long-term kidney transplant outcomes. Moreover, as they were usually based on historical data, it was not possible to account for the presence of pretransplant donor-specific human-leukocyte antigen antibodies (DSA), a currently recognized risk marker for impaired graft survival. The aim of this study was to evaluate to what extent frequently used initial immunosuppressive therapies increase graft survival in immunological low-risk patients.

View Article and Find Full Text PDF

Background: Pre-transplant donor-specific anti-human leucocyte antigen (HLA) antibodies (DSAs) are associated with impaired kidney graft survival while the clinical relevance of non-donor-specific anti-HLA antibodies (nDSAs) is more controversial. The aim of the present paired kidney graft study was to compare the clinical relevance of DSAs and nDSAs.

Methods: To eliminate donor and era-dependent factors, a post hoc paired kidney graft analysis was performed as part of a Dutch multicentre study evaluating all transplantations between 1995 and 2005 with available pre-transplant serum samples.

View Article and Find Full Text PDF

Background: There is no consensus in the literature on the interpretation of single-antigen bead positive for a specific HLA antibody.

Methods: To inform the debate, we studied the relationship between various single-antigen bead positivity algorithms and the impact of resulting donor-specific HLA antibody (DSA) positivity on long-term kidney graft survival in 3237 deceased-donor transplants.

Results: First, we showed that the interassay variability can be greatly reduced when working with signal-to-background ratios instead of absolute median fluorescence intensities (MFIs).

View Article and Find Full Text PDF

Complement-fixing antibodies against donor HLA are considered a contraindication for kidney transplant. A modification of the IgG single-antigen bead (SAB) assay allows detection of anti-HLA antibodies that bind C3d. Because early humoral graft rejection is considered to be complement mediated, this SAB-based technique may provide a valuable tool in the pretransplant risk stratification of kidney transplant recipients.

View Article and Find Full Text PDF

Objectives: The current strategy for antinuclear antibody (ANA) analysis involves screening for presence with a subsequent detailed analysis of their specificity. The aim of this study is to compare the clinical and financial efficacy of this strategy between different commercial tests in a large cohort of unselected patients.

Methods: In all consecutive 1030 patients associations were defined between results from different ANA test systems and the pre-test probability for connective tissue disease (CTDs).

View Article and Find Full Text PDF