Publications by authors named "Bradley Bolster"

Background: Conventional liver magnetic resonance elastography (MRE) requires breath-holding (BH) to avoid motion artifacts, which is challenging for children. While radial free-breathing (FB)-MRE is an alternative for quantifying liver stiffness (LS), previous methods had limitations of long scan times, acquiring two slices in 5 minutes, and not resolving motion during reconstruction.

Purpose: To reduce FB-MRE scan time to 4 minutes for four slices and to investigate the impact of self-gated (SG) motion compensation on FB-MRE LS quantification in terms of agreement, intrasession repeatability, and technical quality compared to conventional BH-MRE.

View Article and Find Full Text PDF

Purpose: To demonstrate a novel MR elastography (MRE) technique, termed here wavelet MRE. With this technique, broadband motion sensitivity is achievable. Moreover, the true tissue displacement can be reconstructed with a simple inverse transform.

View Article and Find Full Text PDF

Objectives: Portal hypertension (PH) is associated with complications such as ascites and esophageal varices and is typically diagnosed through invasive hepatic venous pressure gradient (HVPG) measurement, which is not widely available. In this study, we aim to assess the diagnostic performance of 2D/3D MR elastography (MRE) and shear wave elastography (SWE) measures of liver and spleen stiffness (LS and SS) and spleen volume, to noninvasively diagnose clinically significant portal hypertension (CSPH) using HVPG measurement as the reference.

Methods: In this prospective study, patients with liver disease underwent 2D/3D MRE and SWE of the liver and spleen, as well as HVPG measurement.

View Article and Find Full Text PDF

Background: Magnetic resonance (MR) elastography of the liver measures hepatic stiffness, which correlates with the histopathological staging of liver fibrosis. Conventional Cartesian gradient-echo (GRE) MR elastography requires breath-holding, which is challenging for children. Non-Cartesian radial free-breathing MR elastography is a potential solution to this problem.

View Article and Find Full Text PDF

Purpose: To evaluate performance of 3D magnetic resonance elastography (MRE) using spin-echo echo-planar imaging (seEPI) for assessment of hepatic stiffness compared with 2D gradient-recalled echo (GRE) and 2D seEPI sequences.

Methods: Fifty-seven liver MRE examinations including 2D GRE, 2D seEPI, and 3D seEPI sequences were retrospectively evaluated. Elastograms were analyzed by 2 radiologists and polygonal regions of interests (ROIs) were drawn in 2 different fashions: "curated" ROI (avoiding liver edge, major vessels, and areas of wave interferences) and "non-curated" ROI (including largest cross section of liver, to assess the contribution of artifacts).

View Article and Find Full Text PDF

A magnetic resonance (MR) shear wave elastography technique that uses transient acoustic radiation force impulses from a focused ultrasound (FUS) transducer and a sinusoidal-shaped MR displacement encoding strategy is presented. Using this encoding strategy, an analytic expression for calculating the shear wave speed in a heterogeneous medium was derived. Green's function-based simulations were used to evaluate the feasibility of calculating shear wave speed maps using the analytic expression.

View Article and Find Full Text PDF

A method is presented for tracking the internal deformation of self-oscillating vocal fold models using magnetic resonance imaging (MRI). Silicone models scaled to four times life-size to lower the flow-induced vibration frequency were embedded with fiducial markers in a coronal plane. Candidate marker materials were tested using static specimens, and two materials, cupric sulfate and glass, were chosen for testing in the vibrating vocal fold models.

View Article and Find Full Text PDF

Purpose: To present a novel MR shear wave elastography (MR-SWE) method that efficiently measures the speed of propagating wave packets generated using acoustic radiation force (ARF) impulses.

Methods: ARF impulses from a focused ultrasound (FUS) transducer were applied sequentially to a preselected set of positions and motion encoded MRI was used to acquire volumetric images of the propagating shear wavefront emanating from each point. The wavefront position at multiple propagation times was encoded in the MR phase image using a train of motion encoding gradient lobes.

View Article and Find Full Text PDF

Purpose: The goal of our study is to compare hepatic stiffness measures using gradient-recalled echo (GRE) versus spin-echo echo planar imaging (SE-EPI)-based MR Elastography (MRE) at 3T used to measure hepatic stiffness in a patients with suspected liver diseases.

Materials And Methods: This retrospective study included 52 patients with liver disease who underwent a 3T MRE exam including both an investigational SE-EPI-based technique and a product GRE-based technique. Regions of interest (ROI) were placed on the elastograms to measure elastography-derived liver stiffness as well as the area included within the ROIs.

View Article and Find Full Text PDF

Objective: The objectives of our study were to compare MR elastography (MRE) based on gradient-recalled echo (GRE) imaging with spin-echo echo-planar imaging (SEEPI) and rapid fractional (RF)-GRE MRE sequences at 3 T in terms of liver stiffness (LS) and image quality and to evaluate the effect of liver R2* on image quality.

Materials And Methods: Eighty-one patients underwent 3-T liver MRE with GRE, SE-EPI, and RF-GRE sequences performed in variable order in this study. LS and ROI areas on the LS 95% confidence maps were compared among the three sequences.

View Article and Find Full Text PDF

Purpose: Implement and evaluate a 3D MRI method to measure temperature changes with high spatial and temporal resolution and large field of view.

Methods: A multiecho pseudo-golden angle stack-of-stars (SOS) sequence with k-space weighted image contrast (KWIC) reconstruction was implemented to simultaneously measure multiple quantities, including temperature, initial signal magnitude M(0), transverse relaxation time ( T2*), and water/fat images. Respiration artifacts were corrected using self-navigation.

View Article and Find Full Text PDF

Purpose: To demonstrate the interchangeable neck shape-specific (NSS) coil concept that supplements standard commercial spine and head/neck coils to provide simultaneous high-resolution (hi-res) head/neck imaging with high signal-to-noise ratio (SNR).

Methods: Two NSS coils were constructed on formers designed to fit two different neck shapes. A 7-channel (7ch) ladder array was constructed on a medium neck former, and a 9-channel (9ch) ladder array was constructed on large neck former.

View Article and Find Full Text PDF

Purpose: To propose and validate a method for accurately quantifying renal plasma flow (RPF) with arterial spin labeling (ASL).

Materials And Methods: The proposed method employs a tracer-kinetic approach and derives perfusion from the slope of the ASL difference signal sampled at multiple inversion-times (TIs). To validate the method's accuracy, we performed a HIPAA-compliant and IRB-approved study with 15 subjects (9 male, 6 female; age range 24-73) to compare RPF estimates obtained from ASL to those from a more established dynamic contrast-enhanced (DCE) MRI method.

View Article and Find Full Text PDF

Purpose: To develop a method for rapid prediction of the geometric focus location in MR coordinates of a focused ultrasound (US) transducer with arbitrary position and orientation without sonicating.

Methods: Three small tracker coil circuits were designed, constructed, attached to the transducer housing of a breast-specific MR-guided focused US (MRgFUS) system with 5 degrees of freedom, and connected to receiver channel inputs of an MRI scanner. A one-dimensional sequence applied in three orthogonal directions determined the position of each tracker, which was then corrected for gradient nonlinearity.

View Article and Find Full Text PDF

Purpose: Carotid artery imaging is important in the clinical management of patients at risk for stroke. Carotid intraplaque hemorrhage (IPH) presents an important diagnostic challenge. 3D magnetization prepared rapid acquisition gradient echo (MPRAGE) has been shown to accurately image carotid IPH; however, this sequence can be limited due to motion- and flow-related artifact.

View Article and Find Full Text PDF

Rationale: Computed tomographic (CT) radiography is the reference standard for imaging Mycobacterium avium complex (MAC) lung infection. Magnetic resonance imaging (MRI) has been shown to be comparable to CT for characterizing other pulmonary inflammatory conditions, but has not been rigorously tested for imaging MAC pneumonia.

Objectives: To determine the feasibility of pulmonary MRI for imaging MAC pneumonia and to assess the degree of agreement between MRI and CT for assessing the anatomic features and lobar extent of MAC lung infections.

View Article and Find Full Text PDF

Background And Purpose: The purpose of this study was to determine if magnetic resonance (MR) susceptibility-weighted imaging (SWI) can increase the conspicuity of corticomedullary veins within the white matter lesions of multiple sclerosis (MS) and, thus, aid in distinguishing plaques from leukoaraiosis.

Methods: We retrospectively reviewed MR examinations in 21 patients with a clinical diagnosis of MS and 18 patients with a clinical diagnosis of dementia. Examinations included fluid-attenuated inversion recovery (FLAIR) and SWI sequences obtained in the axial plane.

View Article and Find Full Text PDF

Background: Magnetic resonance elastography (MRE) at 3 T MR has the potential to improve the objective detection of skeletal muscle stiffness.

Purpose: To determine the feasibility of MRE using 3 T MR for measurement of the stiffness of shoulder muscles in subjects.

Material And Methods: This study prospectively evaluated 16 healthy subjects (mean age, 29.

View Article and Find Full Text PDF

Magnetic resonance elastography (MRE) of the liver is a novel noninvasive clinical diagnostic tool to stage fibrosis based on measured stiffness. The purpose of this study is to design, evaluate and validate a rapid MRE acquisition technique for noninvasively quantitating liver stiffness which reduces by half the scan time, thereby decreasing image registration errors between four MRE phase offsets. In vivo liver MRE was performed on 16 healthy volunteers and 14 patients with biopsy-proven liver fibrosis using the standard clinical gradient recalled echo (GRE) MRE sequence (MREs) and a developed rapid GRE MRE sequence (MREr) to obtain the mean stiffness in an axial slice.

View Article and Find Full Text PDF

Four-dimensional flow is a magnetic resonance technology that has undergone significant technical improvements in recent years. With increasingly rapid acquisition times and new postprocessing tools, it can provide a tool for demonstrating and visualizing cardiovascular flow phenomena, which may offer new insights into disease. We present an interesting clinical case in which 4-dimensional flow demonstrates potential etiologies for 2 interesting phenomena in the same patient: (1) development of an unusual aneurysm and (2) cryptogenic stroke.

View Article and Find Full Text PDF

Purpose: Kinetic analysis using dynamic contrast enhanced MRI to assess neovascularization of carotid plaque requires images with high spatial and temporal resolution. This work demonstrates a new three-dimensional (3D) dynamic contrast enhanced imaging sequence, which directly measures the arterial input function with high temporal resolution yet maintains the high spatial resolution required to identify areas of increased adventitial neovascularity.

Theory And Methods: The sequence consists of multiple rapid acquisitions of a saturation prepared dynamic 3D gradient recalled echo (GRE) sequence temporally interleaved with multiple acquisitions of a 2D slice.

View Article and Find Full Text PDF

A number of studies are now collecting diffusion tensor imaging (DTI) data across sites. While the reliability of anatomical images has been established by a number of groups, the reliability of DTI data has not been studied as extensively. In this study, five healthy controls were recruited and imaged at eight imaging centers.

View Article and Find Full Text PDF

Rationale And Objectives: Magnetic resonance elastography (MRE) can noninvasively measure the stiffness of liver tissue and display this information in anatomic maps. Magnetic resonance imaging (MRI) guidance has not previously been used to biopsy segments of heterogeneous stiffness identified on MRE. Dedicated study of MRE in post-liver transplant patients is also limited.

View Article and Find Full Text PDF

Purpose: To compare the diagnostic accuracy of magnetic resonance imaging elastography (MRE) and anatomic MRI features in the diagnosis of severe hepatic fibrosis and cirrhosis.

Materials And Methods: Three readers independently assessed presence of morphological changes associated with hepatic fibrosis in 72 patients with liver biopsy including: caudate to right lobe ratios, nodularity, portal venous hypertension (PVH) stigmata, posterior hepatic notch, expanded gallbladder fossa, and right hepatic vein caliber. Three readers measured shear stiffness values using quantitative shear stiffness maps (elastograms).

View Article and Find Full Text PDF

Objective: The purpose of our study was to compare the utility of MR elastography (MRE) and diffusion-weighted imaging (DWI) in characterizing fibrosis and chronic hepatitis in patients with chronic liver diseases.

Subjects And Methods: Seventy-six patients with chronic liver disease underwent abdominal MRI, MRE, and DWI. Severities of liver fibrosis and chronic hepatitis were graded by histopathologic analysis according to standard disease-specific classifications.

View Article and Find Full Text PDF