Background: The use of two-dimensional (2D) ultrasound for guiding radiofrequency ablation (RFA) of benign thyroid nodules presents limitations, including the inability to monitor the entire treatment volume and operator dependency in electrode positioning. We compared three-dimensional (3D)-guided RFA using a matrix ultrasound transducer with conventional 2D-ultrasound guidance in an anthropomorphic thyroid nodule phantom incorporated additionally with temperature-sensitive albumin.
Methods: Twenty-four phantoms with 48 nodules were constructed and ablated by an experienced radiologist using either 2D- or 3D-ultrasound guidance.
Behavioral variant frontotemporal dementia (bvFTD) is a neurodegenerative disorder characterized by diverse and prominent changes in behavior and personality. One of the greatest challenges in bvFTD is to capture, measure and predict its disease progression, due to clinical, pathological and genetic heterogeneity. Availability of reliable outcome measures is pivotal for future clinical trials and disease monitoring.
View Article and Find Full Text PDFIntroduction: Outcomes following tumor resection vary dramatically among patients with pancreatic ductal adenocarcinoma (PDAC). A challenge in defining predictive biomarkers is to discern within the complex tumor tissue the specific subpopulations and relationships that drive recurrence. Multiplexed immunofluorescence is valuable for such studies when supplied with markers of relevant subpopulations and analysis methods to sort out the intra-tumor relationships that are informative of tumor behavior.
View Article and Find Full Text PDFOutcomes following tumor resection vary dramatically among patients with pancreatic cancer. A challenge in defining predictive biomarkers is to discern within the complex tumor tissue the specific subpopulations and relationships that drive recurrence. Multiplexed immunofluorescence is valuable for such studies when supplied with markers of relevant subpopulations and analysis methods to sort out the intra-tumor relationships that are informative of tumor behavior.
View Article and Find Full Text PDFUltrasound, the primary imaging modality in thyroid nodule management, suffers from drawbacks including: high inter- and intra-observer variability, limited field-of-view and limited functional imaging. Developments in ultrasound technologies are taking place to overcome these limitations, including three-dimensional-Doppler, -elastography, -nodule characteristics-extraction, and novel machine-learning algorithms. For thyroid ablative treatments and biopsies, perioperative use of three-dimensional ultrasound opens a new field of research.
View Article and Find Full Text PDFEur Neuropsychopharmacol
November 2022
Social dysfunction is commonly present in neuropsychiatric disorders of schizophrenia (SZ) and Alzheimer's disease (AD). Theory of Mind (ToM) deficits have been linked to social dysfunction in disease-specific studies. Nevertheless, it remains unclear how ToM is related to social functioning across these disorders, and which factors contribute to this relationship.
View Article and Find Full Text PDFIntroduction And Hypothesis: Conventional defecography and MRI defecography can be requested as an additional test for diagnosing and differentiating the type of posterior compartment prolapse and/or obstructive defecation disorders. The objective of this study was to determine the added value of conventional defecography, conventional defecography and MRI defecography for clinical decision-making on treatment for patients with posterior compartment prolapse.
Methods: Four gynecologists were asked to fill in their treatment plan per patient for 32 cases for three different steps.
The left temporal lobe is an integral part of the language system and its cortical structure and function associate with general intelligence. However, whether cortical laminar architecture and cellular properties of this brain area relate to verbal intelligence is unknown. Here, we addressed this using histological analysis and cellular recordings of neurosurgically resected temporal cortex in combination with presurgical IQ scores.
View Article and Find Full Text PDFBackground: Two-dimensional (2D) ultrasound is well established for thyroid nodule assessment and treatment guidance. However, it is hampered by a limited field of view and observer variability that may lead to inaccurate nodule classification and treatment. To cope with these limitations, we investigated the use of real-time three-dimensional (3D) ultrasound to improve the accuracy of volume estimation and needle placement during radiofrequency ablation.
View Article and Find Full Text PDFMucoepidermoid carcinoma (MEC) of the airways is a rare entity most often found in young patients. We present a case of a 23 year old patient with symptoms of pneumonia, which progresses to a pulmonary abscess within a week. Diagnostic work-up reveals an endobronchial obstruction by a pedunculated low grade MEC.
View Article and Find Full Text PDFCardiovasc Intervent Radiol
September 2016
J Belg Soc Radiol
February 2016
Objectives: Quantitative analysis of operator dose in cone-beam computed tomography guidance (CBCT-guidance) and the effect of protective shielding.
Methods: Using a Rando phantom, a model was set-up to measure radiation dose for the operator hand, thyroid and gonad region. The effect of sterile radiation-absorbing drapes and ceiling/couch shielding was measured.
Purpose: To evaluate the safety and long-term outcome of percutaneous cholecystostomy (PC) under radiologic guidance for acute calculous cholecystitis (ACC) and acute acalculous cholecystitis (AAC) in all patients undergoing that procedure at our institution.
Materials And Methods: We performed a retrospective analysis of 111 patients who underwent PC from 2004 to 2012. Patients were divided into two groups: AAC and ACC.
Objective: To determine the accuracy of cone beam CT (CBCT) guidance and CT guidance in reaching small targets in relation to needle path complexity in a phantom.
Methods: CBCT guidance combines three-dimensional CBCT imaging with fluoroscopy overlay and needle planning software to provide real-time needle guidance. The accuracy of needle positioning, quantified as deviation from a target, was assessed for inplane, angulated and double angulated needle paths.
Necrotising fasciitis (NF) is an extremely virulent form of infectious fasciitis. It affects skin, subcutaneous fat and superficial and deep muscular fascia by rapidly progressive necrosis. Expeditious diagnosis and radical debridement is necessary to prevent the onset of sepsis, multisystem organ failure and possible death.
View Article and Find Full Text PDFObjective: To investigate the accuracy, procedure time, fluoroscopy time, and dose area product (DAP) of needle placement during percutaneous vertebroplasty (PVP) using cone-beam computed tomography (CBCT) guidance versus fluoroscopy.
Materials And Methods: On 4 spine phantoms with 11 vertebrae (Th7-L5), 4 interventional radiologists (2 experienced with CBCT guidance and two inexperienced) punctured all vertebrae in a bipedicular fashion. Each side was randomization to either CBCT guidance or fluoroscopy.
A number of masses arise in relation to the thymus.The radiologist has an important role regarding the differential diagnosis between non-tumoral thymic pathology and malignant thymic tumors. In general, a benign hyperplasia of the thymus occurs in children and young adults, while in adults the thymoma is the most common tumor.
View Article and Find Full Text PDFObjective: To determine whether 3D cone-beam computed tomography (CBCT) guidance allows safe and accurate biopsy of suspected small renal masses (SRM), especially in hard-to-reach anatomical locations.
Materials And Methods: CBCT guidance was used to perform 41 stereotactic biopsy procedures of lesions that were inaccessible for ultrasound guidance or CT guidance. In CBCT guidance, a 3D-volume data set is acquired by rotating a C-arm flat-panel detector angiosystem around the patient.
Purpose: To evaluate the outcome of percutaneous lung biopsy (PLB) findings using cone-beam computed tomographic (CT) guidance (CBCT guidance) and compared to conventional biopsy guidance techniques.
Methods: CBCT guidance is a stereotactic technique for needle interventions, combining 3D soft-tissue cone-beam CT, needle planning software, and real-time fluoroscopy. Between March 2007 and August 2010, we performed 84 Tru-Cut PLBs, where bronchoscopy did not provide histopathologic diagnosis.
Purpose: To determine effective radiation dose to patients during needle interventions with cone-beam computed tomography (CT) guidance and compare it with the dose during conventional CT-guided interventions.
Materials And Methods: Cone-beam CT guidance is a recently developed technique with image acquisition on a flat-panel detector digital angiography system. It is based on a combination of acquired three-dimensional soft-tissue cone-beam CT, dedicated needle trajectory software, and fluoroscopy, providing stereotactic needle guidance.