An optical pumping scheme is proposed for reducing the gradient of electron spin polarization and suppressing light source noise in a spin-exchange relaxation-free magnetometer. This is achieved by modulating only the phase of a narrow-linewidth pump light field with external Gaussian noise. Compared to the absence of phase modulation, the uniformity of electron spin polarization was improved by over 40%, and the light-frequency noise suppression ratio of the magnetometer was enhanced by 4.
View Article and Find Full Text PDFRb optically pumped magnetometer (OPM) based on electron paramagnetic resonance (EPR) show advantages to measure the nuclear magnetization and have succeeded in fundamental physics and rotation sensing, etc. The magnetometry sensitivity is a key performance of these Rb OPMs which should be improved. In this study, a high sensitivity Rb OPM is demonstrated theoretically and experimentally.
View Article and Find Full Text PDFThe existence of an approximately uniform and unsaturated electron spin polarization distribution within a high-density alkali-metal vapor is considered of great importance for significantly improving the response amplitude and sensitivity properties of an atomic magnetometer. However, when a high-density alkali-metal vapor is formed, the optical depth is much larger than the value of one, resulting in the electron spin polarization gradient. In this work, it was demonstrated from both numerical simulations and experimental points of view, that by replacing the resonant pumping light with two off-resonant pumping light sources, the signal amplitude of the magnetometer can be doubled.
View Article and Find Full Text PDFWe analyze and suppress the magnetic noise response in optical rotation detection system (ORDS) in atomic magnetometers in this study. Because of the imperfections of the optical elements, the probe light is actually elliptically polarized in ORDS, which can polarize the atom ensemble and cause the responses to the three-axis magnetic noise. We theoretically analyze the frequency responses to the magnetic noise, and prove that the responses are closely associated with the DC magnetic field.
View Article and Find Full Text PDFIn the spin-exchange relaxation-free (SERF) magnetometer, the probe noise is a consequential factor affecting the gradiometric measurement sensitivities. In this paper, we proposed a new characteristics model of the probe noise based on noise separation. Different from noise analysis on single noise source, we considered most of the noise sources influencing the probe system and realized noise sources level measurement experimentally.
View Article and Find Full Text PDFUltra-sensitive multi-channel optically pumped atomic magnetometers based on the spin-exchange relaxation-free (SERF) effect are powerful tools for applications in the field of magnetic imaging. To simultaneously achieve ultra-high spatial resolution and ultra-high magnetic field sensitivity, we proposed a high-resolution multi-channel SERF atomic magnetometer for two-dimensional magnetic field measurements based on a digital micro-mirror device (DMD) as the spatial light modulator for a single vapor cell. Under the optimal experimental conditions obtained via spatial and temporal modulation of the probe light, we first demonstrated that the average sensitivity of the proposed 25-channel magnetometer was approximately 25fT/Hz with a spatial resolution of 216µm.
View Article and Find Full Text PDF