The determination of activity concentrations of the CTBT-relevant radioxenon relies on a robust calibration method. A procedure is outlined using four radioxenon spikes for beta-gamma detector-systems with 4π geometry. Detection efficiencies of beta-gamma coincidences in the net count calculation method, including the interference matrix between radioxenon and radon, are determined by three measurement channels: beta singles, gamma singles and beta-gamma coincidences, without reference activity values.
View Article and Find Full Text PDFFor the enhancement of the International Data Centre's products, specifically the Standard Screened Radionuclide Event Bulletin, an important step is to establish methods to associate the detections of the Comprehensive Nuclear-Test-Ban Treaty-relevant nuclides in different atmospheric radioactivity samples with the same radionuclide release to characterize its source for the purpose of nuclear explosion monitoring. Episodes of anomalously high activity concentrations in samples at the International Monitoring System radionuclide stations are used as the primary assumption for being related to the same release. For multiple isotope observations, the consistency of their isotopic ratios in subsequent samples with radioactive decay is another plausible hint for one unique release.
View Article and Find Full Text PDFIntroduction: Intracerebral hemorrhage (ICH) is the most fatal type of stroke worldwide. Herein, we aim to develop a predictive model based on computed tomography (CT) markers in an ICH cohort and validate it in another cohort.
Methods: This retrospective observational cohort study was conducted in 3 medical centers in China.
Drug Des Devel Ther
December 2020
Purpose: Isoborneol has been used in the treatment of cardiovascular disease for several years in China. However, the mechanism is still unclear. The aim of this study was to identify the novel mechanism of isoborneol for its application in atherosclerotic disease.
View Article and Find Full Text PDFThe aim of this study was to assess the accuracy of the results of whole-body measurements by comparison with the urine collection method in the PRRT with (177)Lu and furthermore to develop a more accurate method of paired measurements. Excreted samples were collected at given intervals and activities were measured by a dose calibrator. Traditionally, whole-body activities during subsequent measurements are normalized individually to the administered activity.
View Article and Find Full Text PDF