Purpose: The number of presbyopia-correcting (premium) intraocular lenses (IOLs) is growing steadily as the desire for spectacle independence after cataract surgery increases. The aim of this laboratory study was to evaluate a newly launched hydrophobic, acrylic, polyfocal, refractive intraocular lens with a new optical design and geometry. This polyfocal IOL has three different zones (within the optic) with radially asymmetric design.
View Article and Find Full Text PDFIntroduction: The geometry of an intraocular lens (IOL), the design of the haptics, and the optic-haptic junction play a role in initial and long-term visual outcome after cataract surgery. Knowledge of the behavior of an implant in the capsular bag and under compression is of major importance. Our laboratory experiment analyzed in-depth the geometry of acrylic, single-piece, premium, presbyopia-correcting intraocular lenses and changes in haptic-capsular bag relationships according to capsular bag size using a range of compression well diameters.
View Article and Find Full Text PDFIntroduction The material of modern intraocular lenses must meet the highest standards and fulfill various requirements. It is crucial that the material shows the best biocompatibility and should be flexible for an uncomplicated implantation process through small corneal incisions but also sufficiently rigid for good stability and centering in the capsular bag. In addition, the optic must remain clear for life and retain the best optical properties.
View Article and Find Full Text PDFIntroduction: Pinhole intraocular lenses (IOLs) were developed to improve reading by compensating for loss of accommodative function. The IC-8 Apthera™ is a small-aperture presbyopia-correcting IOL that combines the proven principle of small-aperture optics with an aspheric monofocal lens to deliver a continuous range of vision for patients with cataracts from distance to near vision. Posterior capsule opacification is the most common sequela after cataract surgery.
View Article and Find Full Text PDFPurpose: Neodymium yttrium aluminum garnet (Nd:YAG) laser capsulotomy is considered gold standard in the treatment of posterior capsule opacification (PCO). In this laboratory study, we measured spectral transmission to evaluate the image contrast and analyze the impact of Nd:YAG associated defects in presbyopia-correcting intraocular lenses (IOLs).
Methods: Two hydrophobic, acrylic IOLs as classic multifocal lenses with diffractive ring segments and different amount of near addition (A, B), one hydrophilic, trifocal IOL (C), one sector-shaped, plate haptic IOL (D) and one hydrophobic, enhanced depth of focus (EDOF) IOL (E) were studied.
In ophthalmology, intravitreal therapies are currently not personalized/customized and are not adjusted to the individual vitreous volume. With reference to the recently published calculation formula for a more accurate estimation of the vitreous body, we determined the dose of intravitreal medication for different vitreous volumes and compared them with the average volume. Using the axial length of the eye, the formula for the vitreous volume exact (VIVEX) can provide a more accurate indication of the vitreous volume in individual cases than an assumed standard volume of 4 mL.
View Article and Find Full Text PDFPurpose: Any new intraocular lens (IOL) on the market claims to outperform competitors. We aimed to estimate the modulation transfer function (MTF) for different defocus of a novel refractive enhanced depth of focus (EDoF) IOL and the simulated visual acuity over this range of vision. Further, we analyzed the wavefront pattern produced by this IOL to reveal the function of the IOL's optics.
View Article and Find Full Text PDFNowadays, lasers are used in various medical fields. Ophthalmology was the first medical specialty to utilize lasers in patient treatment and still remains the leading medical field that uses laser energy for both therapeutic and diagnostic purposes. The neodymium: yttrium-aluminum-garnet (Nd: YAG) laser is one of the most common lasers used in ophthalmology.
View Article and Find Full Text PDFIntroduction: Cataract extraction is the most frequently performed ophthalmological procedure worldwide. Posterior capsule opacification remains the most common consequence after cataract surgery and can lead to deterioration of the visual performance with cloudy, blurred vision and halo, glare effects. Neodymium-doped yttrium aluminum garnet (Nd:YAG) laser capsulotomy is the gold standard treatment and a very effective, safe and fast procedure in removing the cloudy posterior capsule.
View Article and Find Full Text PDFObjective: To compare the optic-haptic interaction of different hydrophobic acrylic IOLs after using six preloaded injectors.
Methods: We reviewed the video-recordings of procedures on a total of 388 eyes that underwent phacoemulsification and intraocular lens (IOL) implantation. For six preloaded injectors: multiSert (Hoya Surgical Optics) [System 1], TECNIS Simplicity (Johnson & Johnson Vision) [System 2], TECNIS iTec (Johnson & Johnson Vision) [System 3], AutonoMe (Alcon, Laboratories) [System 4], Bluesert (Carl Zeiss Meditec) [System 5], and Prosert (OphthalmoPro GmbH) [System 6], we noted in each case the time of IOL delivery and made a descriptive observation of IOL insertion and optic-haptic-interaction.
Introduction: Personalized medicine and patient-tailored drug dosing have been substantiated through thousands of clinical studies, demonstrating their safety and efficacy. The principle: "as much as necessary, as little as possible" is widely spread. Quantities and doses are therefore adjusted individually.
View Article and Find Full Text PDFIntroduction: Enhanced monofocal intraocular lenses (IOLs) represent a new type of lens, which should lead to a very good distance vision similar to monofocal IOLs and an improved intermediate vision without increasing the risk for photic phenomena.
Methods: The aim of this clinical observation/registry study was to directly compare two different IOL platforms (hydrophilic acrylic L-333 (group A) vs hydrophobic acrylic AN6Q (group B)) with the same enhanced monofocal optic principle but different material and haptic design in clinical routine. A total of 102 cataract cases (51:51) were included in the study.
Purpose: Neodymium yttrium aluminum garnet (Nd:YAG) laser capsulotomy is considered as safe and effective method in the treatment of posterior capsule opacification. Nevertheless, side effects are described. The incorrectly adjusted focus of the laser beam during the procedure can lead to so-called YAG-pits or YAG-shots.
View Article and Find Full Text PDFIntroduction: Intraocular lenses (IOL) should remain in the eye for life after implantation into the capsular bag during cataract surgery. The material must meet various requirements. It is crucial that the material has the best biocompatibility, and it should be flexible and soft for best possible implantation process but also sufficiently stable and stiff for good centering in the eye and posterior capsule opacification prevention.
View Article and Find Full Text PDFIntroduction: A new class of nondiffractive, wavefront-shaping Enhanced-Depth-of-Focus (EDoF) IOLs has been introduced very recently to cope with photic phenomena known from diffractive EDoF IOLs. We investigated the through focus modulation transfer function (MTF) of two wavefront-shaping EDoF IOLs compared to an established diffractive EDoF IOL on the optical bench. Such comparison on the optical bench had not been performed before and is of high clinical importance for the cataract surgeon.
View Article and Find Full Text PDFBackground: Neodymium:yttrium aluminum garnet (Nd:YAG) laser capsulotomy is a well-accepted, safe, and effective measure in the treatment of posterior capsule opacification. However, iatrogenic intraocular lens damage is a relatively common side effect that happens due to inappropriate focusing during the procedure. This experimental study analyzes the impact of YAG-pits to obtain qualitative information.
View Article and Find Full Text PDFIntroduction: Posterior capsule opacification (PCO) is the most frequent late sequelae after successful cataract surgery. Neodymium:yttrium aluminum garnet (Nd:YAG) laser capsulotomy is considered the gold standard and a well-accepted, safe, and effective measure in treating PCO. However, iatrogenic damage of the intraocular lens (IOL) due to inappropriate focusing is a quite common side effect.
View Article and Find Full Text PDFPurpose: To analyze the effect of decentration and tilt on four novel non diffractive extended range of vision intraocular lenses (IOLs).
Methods: Acrysof Vivity, LuxSmart Crystal, RayOne EMV and Tecnis Eyhance were compared on the optical bench (power of 22 D each). Modulation transfer functions were obtained and Strehl ratio was calculated in an ISO-2 model.
Purpose: To assess the depth of focus of four latest non-diffractive extended range of vision IOLs on the optical bench. Such comparison had not been done before.
Methods: We assessed and compared the through focus modulation transfer function (MTF) of the following novel IOLs with a nominal power of 22 D: Acrysof Vivity, LuxSmart Crystal, RayOne EMV and Tecnis Eyhance.
Introduction: The aim of this laboratory study is to objectively analyze the new hydrophobic, acrylic, enhanced monofocal intraocular lens Acunex Quantum (AN6Q) and compare it with the monofocal platform Acunex AN6. METHODS: Two IOL models were analyzed (Acunex Quantum AN6Q and Acunex AN6, Teleon Surgical, Spankeren, Netherlands), each having the same refractive power of + 22.0 D, on the optical bench with the OptiSpheric IOL PRO 2.
View Article and Find Full Text PDFIntroduction: The aim of the study was to analyze the optical properties of a new hydrophilic enhanced monofocal intraocular lens (IOL) using optical bench analysis and compare it with its monofocal counterpart.
Methods: This laboratory study investigates the enhanced monofocal intraocular lens (L-333) and the monofocal counterpart (L-313) IOL by Teleon Surgical, Spankeren, Netherlands on the optical bench, using OptiSpheric IOL PRO2 (Trioptics, Germany) in order to assess the optical quality according to ISO 11979 with ISO-2 Cornea. IOLs (power 22.
Age-related macular degeneration (AMD) results in progressive vision loss that significantly impacts patients' quality of life and ability to perform routine daily activities. Although pharmaceutical treatments for AMD are available and in clinical development, patients with late-stage AMD are relatively underserved. Specialized rehabilitation programs and external low-vision aids are available to support visual performance for those with advanced AMD; but intraocular vision-improving devices, including implantable miniature telescope (IMT) and intraocular lens (IOL) implants, offer advantages regarding head motion, vestibular ocular reflex development, and depth perception.
View Article and Find Full Text PDF