Objectives: Numerous studies have been conducted on the adaptation of dental restorations fabricated by additive (AM) and subtractive manufacturing (SM); however, the results are conflicting. This systematic review and meta-analysis aimed to evaluate the fit and trueness of fixed restorations made by AM compared to SM.
Data: Studies investigating internal fit, marginal fit, and trueness of fixed prostheses were involved.
Purpose: The study aims to produce CAD-CAM reference samples for shade communication milled from the material of the restoration zirconia (ZrO2) and zirconia-reinforced lithium silicate (ZLS) and evaluate the color difference with the corresponding conventional Vita Classical (VC) shade tab. Furthermore, it aims to verify the color consistency of the materials.
Materials And Methods: Five-five samples were milled out of ZrO2 and ZLS in five different colors and their color parameters were compared with the corresponding VC tabs both visually and digitally.
Objective: The objective was to investigate the dimensional stability of different types of 3D printed dental models, and to measure the dimensional changes over time.
Methods: Four dental casts with different constructions were printed. The four types of models were as follows: hollow casts with 2.
Background: Effects of ceramic translucency, layer thickness, and substrate colour on the shade of lithium disilicate glass-ceramic restorations proved to be significant in several studies, however, quantitative, numerical results on the relationship between the colour difference and these parameters are still lacking. The purpose of this in vitro study was to quantitatively determine how the colour reproduction ability of a lithium disilicate glass-ceramic is affected by its translucency, layer thickness, and substrate colour.
Methods: Ceramic samples were prepared from A2 shade IPS e.
Objectives: To assess the impact of including the palate and the number of images recorded during intraoral digital scanning procedure on the accuracy of complete arch scans.
Methods: An experienced operator conducted 40 digital scans of a 3D printed maxillary model and divided them into two groups: 20 with inclusion of the palate (PAL) and 20 without (NPAL). Each set of scans was performed using an intraoral scanner (IOS) (Trios 5; 3Shape A/S; Copenhagen, Denmark).
Problem: Several types of 3D printers with different techniques and prices are available on the market. However, results in the literature are inconsistent, and there is no comprehensive agreement on the accuracy of 3D printers of different price categories for dental applications.
Aim: This study aimed to investigate the accuracy of five different 3D printing systems, including a comparison of budget- and higher-end 3D printing systems, according to a standardized production and evaluation protocol.
Statement Of Problem: Patients with oro-antral communication, whether from trauma, disease, or congenital anomalies, have options for surgical reconstruction or prosthetic obturation, but guiding interdisciplinary protocols are lacking.
Purpose: The purpose of this systematic review and meta-analysis was to compare surgical reconstruction and prosthetic obturation, identifying correlations with baseline characteristics to determine the most effective approach for specific patients.
Material And Methods: A systematic search was conducted in 4 databases.
There is a growing need for effective methods in the management of early stage carious lesions. Therefore, the aim of this study was to evaluate the effect of combined casein phosphopeptide-amorphous calcium phosphate (CPP-ACP) and fluoride on white spot lesions (WSLs) compared to fluoride-only interventions. This meta-analysis was performed according to PRISMA guidelines and registered in PROSPERO (CRD42021286245).
View Article and Find Full Text PDFPurpose: This study is aimed to evaluate the effect of generation change on accuracy of IOSs on full-arch scans and the inter-operator reliability.
Methods: In this study, 6 different IOS were tested: 3Shape Trios 3 (20.1.
Objectives: This network meta-analysis (NMA) aimed to compare the complete-arch scanning accuracy of different intraoral scanners (IOSs) to that of reference standard tessellation language (STL) files.
Data: Studies comparing the trueness and precision of IOS STL files with those of reference STL scans for different arch types (dentate, edentulous, completely edentulous with implants, and partially edentulous with implants) were included in this study.
Sources: An electronic search of five databases restricted to the English Language was conducted in October 2021.
Recent developments aim to extend the cytotoxic effect and therapeutic window of mAbs by constructing antibody-drug conjugates (ADCs), in which the targeting moiety is the mAb that is linked to a highly toxic drug. According to a report from mid of last year, the global ADCs market accounted for USD 1387 million in 2016 and was worth USD 7.82 billion in 2022.
View Article and Find Full Text PDFObjective: The aim of this in vitro study is to evaluate the masking ability of polymer-infiltrated ceramic-network materials (PICN) with different translucencies and thicknesses on multiple types of substrates.
Materials And Methods: Ceramic samples were prepared of VITA ENAMIC blocks in two different translucencies (2M2-T, 2M2-HT) in a thickness range of 0.5-2.
Purpose To assess the accuracy of scanning technologies for constructing facial prostheses on human faces.Study selection Our systematic search was performed on five databases. Studies reporting on human volunteers (P) whose faces were scanned with a scanning technology were eligible.
View Article and Find Full Text PDFPurpose Temporomandibular disorders (TMDs) are frequent stomatological disorders. However, their treatment is controversial. Therefore, we compared the efficacy of combination therapy (splint therapy along with physiotherapy, manual therapy, and counseling) with physiotherapy, manual therapy, and counseling alone.
View Article and Find Full Text PDFBackground: The appearance of intraoral scanners (IOSs) in dental offices was an important milestones for the digital innovations in dentistry. Knowing the learning curve for intraoral scanning is crucial, because it can serve as a guideline for clinicians before buying a new IOS. The aim of the present in vivo study was to determine the learning curve required by dental students for intraoral scanning with the 3Shape Trios 4 IOS and the CEREC Primescan IOS, based on scanning time.
View Article and Find Full Text PDFIntroduction: Intraoral scanners (IOS) are continuing to gain popularity in clinical dentistry, replacing the traditional impression-taking and related technology. Despite their increasing importance, there are few data on the utility and usage of IOS amongst dentists. This study investigates the user experience of IOS technology as well as the perceived quality of a variety of IOS used by dental clinicians worldwide.
View Article and Find Full Text PDFObjectives: Thus far, the findings of numerous studies conducted on the accuracy of three-dimensional (3D) printed dental models are conflicting. Therefore, the aim of the network meta-analysis (NMA) is to determine the accuracy of 3D printed dental models compared with digital reference models.
Data: Studies comparing the accuracy of 3D printed full-arch dental models manufactured using different printing techniques to initial STL files were included.
Background: Digital workflow is showing an increasing tendency in everyday dentistry. Accuracy is essential during digital dental workflows for all indication areas. The present study aimed to evaluate the effect of software updates on the accuracy of intraoral scanner (IOS) devices.
View Article and Find Full Text PDFBackground: The evolution of intraoral scanners (IOSs) is rapid, and new IOSs appear on the market with different properties depending on the manufacturers. There is no uniform rating system based on a defined set of aspects that has reported in the literature that can be used to compare these devices. This validation study aimed to compare different IOSs based on objective and comprehensive parameters.
View Article and Find Full Text PDFBruton's tyrosine kinase inhibitors have changed the treatment landscape for chronic lymphocytic leukemia (CLL), mantle cell lymphoma (MCL) and lymphoplasmacytic lymphoma dramatically. In 2019, acalabrutinib was approved by the US FDA for the treatment of treatment-naive and relapsed/refractory CLL and MCL. Acalabrutinib monotherapy was found to be effective and safe in CLL patients.
View Article and Find Full Text PDFObjective: Trios3 (3Shape, Denmark) intraoral scanner is complete with a tooth shade measurement function, but there is limited information about its efficacy. This in vivo study aimed to evaluate this function in relation to visual and spectrophotometric shade determination.
Materials And Methods: Ten dental students from Semmelweis University determined tooth shade for 10 volunteers using Vita A1-D4 (VC) and Vita Linearguide 3D-Master (LG) guides, Vita Easyshade spectrophotometer (ES) and Trios 3 intraoral scanner (TR).