This study investigates the utilization of poly(vinyl alcohol) (PVA)/gelatin hydrogel films cross-linked with glutaraldehyde as a novel material to coat the surface of vancomycin-loaded titania nanotubes (TNTs), with a focus on enhancing biocompatibility and achieving controlled vancomycin release. Hydrogel films have emerged as promising candidates in tissue engineering and drug-delivery systems due to their versatile properties. The development of these hydrogel films involved varying the proportions of PVA, gelatin, and glutaraldehyde to achieve the desired properties, including the gel fraction, swelling behavior, biocompatibility, and biodegradation.
View Article and Find Full Text PDFPurpose: To report preliminary clinical results and safety of 3D-printed patient-specific titanium radial head (RH) prosthesis in treatment of the irreparable RH fractures.
Material And Methods: This multi-centric prospective study included 10 patients (6 men and four women, mean age 41 years (range, 25-64 years)). Three cases were classified as Mason type III and 7 cases as type IV.
Due to its superior mechanical properties and chemical stability, Polyetheretherketone (PEEK) has emerged as an alternative to conventional metal implants. However, the bio-inertness of PEEK's surface has limited its applications. Ambient sulfonation has been adopted to enhance bioactivity, but its nanoscale topographic changes are insufficient for implant-bone interlock.
View Article and Find Full Text PDFThe aim of this study is to assess the stress distribution on the bone tissue and bone-implant interface of a customized anatomic root-analog dental implant (RAI) by means of finite element analysis (FEA) for different types of bone density. A mandibular right second premolar was selected from the CBCT database. A DICOM file was converted to an STL file to create a CAD model in FEA software.
View Article and Find Full Text PDFUnlabelled: Complex orbital fractures, including orbital rims and walls, require precise reconstruction. A titanium-based patient-specific implant (PSI) benefits over other implants when challenged with narrow surgical space and designable implant fixation point.
Methods: This is a prospective noncomparative case series to evaluate the effect of complex orbital reconstruction using the newly designed lateral fixation patient-specific implant.
The aim of this study is to synthesize Titania nanotubes (TNTs) on the 3D-printed Ti-6Al-4V surface and investigate the loading of antibacterial vancomycin drug dose of 200 ppm for local drug treatment application for 24 h. The antibacterial drug release from synthesized nanotubes evaluated via the chemical surface measurement and the linear fitting of Korsmeyer-Peppas model was also assessed. The TNTs were synthesized on the Ti-6Al-4V surface through the anodization process at different anodization time.
View Article and Find Full Text PDFBackground: Recently, medical three-dimensional printing technology (3DPT) has demonstrated potential benefits for the treatment of cubitus varus deformity (CVD) by improving accuracy of the osteotomy through the use of an osteotomy guide, with or without a patient-mated plate. Here, we present an interesting CVD case, involving a patient who was treated with corrective biplanar chevron osteotomy using an innovative customized osteotomy guide and a newly designed patient-matched monoblock crosslink plate created with 3DPT.
Case Summary: A 32-year-old female presented with a significant CVD from childhood injury.
Comput Methods Biomech Biomed Engin
May 2021
This study aims to evaluate the mechanical performance of custom 3D-printed titanium plates in the treatment of distal humerus fractures. Rigidity of four plating configurations were investigated by finite element analysis. The results reveal that implementation of custom designs with minimal screw holes, lateral-medial linking screw and lateral brim could significantly improve stiffness and consequently leads to better biomechanical stability as compared to standard osteosynthesis design.
View Article and Find Full Text PDFPlast Reconstr Surg Glob Open
September 2020
We present the case of an 18-year-old man who was referred to our department with a suspected tumor in the right orbital region, which caused exophthalmos due to its pressure effect. Preoperative CT imaging revealed an expansile ground-glass appearance of bone mass, with sclerotic bone on the right frontal bone (right superior orbital wall). There was no orbital mass and no enlargement of the extraocular muscles and tendons; the retrobulbar fat and optic nerve appeared unremarkable.
View Article and Find Full Text PDFInt J Surg Case Rep
June 2020
Introduction: The majority of patients with bone sarcoma or an aggressive benign tumor of the toe can be successfully treated by amputation. However, limb-salvage surgery for toe tumors remains challenging.
Presentation Of Case: A 26-year-old female presented with an enlarging mass on her right 5th toe.
Background: Midshaft clavicular fractures are common fractures and generally treated conservatively. Among the surgical options, plate fixation is the most popular and has been biomechanically and clinically proven in numerous studies. However, implant failures caused by plate deformations or breakage still occur in up to 16.
View Article and Find Full Text PDFJ Orthop Surg (Hong Kong)
March 2020
Purpose: Following the radial head replacement, the surface mismatches between the implants and the morphological characteristics of the original proximal radius decreased contact areas and increased contact forces which is potential for the long-term articulating cartilage wear. Several studies demonstrated that the individualized prosthesis, created from computed tomographic (CT) images of the contralateral side with the reverse engineering technology, may reduce the mismatch. The aim of this study is to demonstrate the matching precision of the reverse contralateral head between the surface registration in tuberosity-neck (TN) area and in tuberosity-diaphysis (TD) area.
View Article and Find Full Text PDFSuccessful treatment of the chronic persistent elbow instability is a challenge for orthopedic surgeons. In this form, it is important to recognize and restore the osseous stabilizer in order to obtain the concentric reduction. In the present report, we describe a case of such injury with irreparable radial head treated with patient-specific radial head prosthesis which was created with 3D printing technology.
View Article and Find Full Text PDFGiant cell tumor of the bones occurring in the first metacarpals frequently requires entire metacarpal resection due to the aggressive nature and high rate of recurrence. Bone reconstruction can be performed with autogenous bone grafts. Here we describe a new technique of reconstruction using a patient-matched three-dimensional printed titanium first metacarpal prosthesis.
View Article and Find Full Text PDF