Publications by authors named "Bong-Jae Jun"

Background: Prognostic factors for total shoulder arthroplasty (TSA) clinical outcomes are incompletely understood. This study investigates the associations of preoperative patient, disease-specific, and surgical factors with 1-year postoperative PENN Shoulder Score (PSS) in patients undergoing primary TSA.

Methods: Cleveland Clinic patients undergoing primary anatomic TSA (aTSA) or reverse TSA (rTSA) for glenohumeral osteoarthritis (GHOA) or rotator cuff tear arthropathy (CTA) between February 2015 and August 2019, and having complete preoperative and 1-year postoperative patient-reported outcome measures (PROMs), were included.

View Article and Find Full Text PDF

Glenoid component loosening remains a common complication following anatomic total shoulder arthroplasty (TSA); however, plain radiographs are unable to accurately detect early implant migration. The purpose of this study was to validate the accuracy of a method of postoperative, three-dimensional (3D) computed tomography (CT) imaging with metal artifact reduction (MAR) to detect glenoid component migration following anatomic TSA. Tantalum bead markers were inserted into polyethylene glenoid components for implant detection on 3D CT.

View Article and Find Full Text PDF

Background: Posterior glenoid bone loss is commonly associated with primary glenohumeral osteoarthritis. Surgical management of bone loss in anatomic total shoulder arthroplasty (aTSA) remains controversial. We studied the use of a stepped augmented glenoid component for management of Walch B2 and B3 glenoids and compared the radiographic and clinical outcomes at short-term follow-up with those achieved with a non-augmented component of the same design in Walch A1 glenoids.

View Article and Find Full Text PDF
Article Synopsis
  • This study aimed to analyze the position and radiolucency of glenoid components in patients who underwent anatomic total shoulder arthroplasty (TSA) using 3D CT imaging at various time points.
  • Out of 152 patients, 51% experienced a shift in the glenoid component position after surgery, and 13% showed signs of central anchor peg osteolysis (CPO), but most patients with component shift did not develop CPO.
  • The study found that certain glenoid types and preoperative joint conditions were associated with a higher likelihood of glenoid component shift and CPO, but neither condition negatively affected clinical outcomes.
View Article and Find Full Text PDF

Background: To address the need for more objective and quantitative measures of tendon healing in research studies, we intend to use computed tomography (CT) with implanted radiopaque markers on the repaired tendon to measure tendon retraction following rotator cuff repair. In our small prior study, retraction at 1-year follow-up averaged 16.1± 5.

View Article and Find Full Text PDF

Background: The purpose of this study was to quantify correction of glenoid deformity and humeral head alignment in anatomic total shoulder arthroplasty as a function of preoperative pathology (modified Walch classification) and glenoid implant type in a clinical cohort using 3-dimensional computed tomography (CT) analysis.

Methods: Patients undergoing anatomic total shoulder arthroplasty with a standard glenoid (SG) (n = 110) or posteriorly stepped augmented glenoid (AG) (n = 62) component were evaluated with a preoperative CT scan and a postoperative CT scan within 3 months of surgery. Glenoid version, inclination, and medial-lateral (ML) joint line position, as well as humeral head alignment, were assessed on both CT scans, with preoperative-to-postoperative changes analyzed relative to pathology and premorbid anatomy based on the modified Walch classification and glenoid implant type.

View Article and Find Full Text PDF

Background: Variations in glenoid morphology affect surgical treatment and outcome of advanced glenohumeral osteoarthritis (OA). The purpose of this study was to assess the inter- and intraobserver reliability of the modified Walch classification using 3-dimensional (3D) computed tomography (CT) imaging in a multicenter research group.

Methods: Deidentified preoperative CTs of patients with primary glenohumeral OA undergoing anatomic or reverse total shoulder arthroplasty (TSA) were reviewed with 3D imaging software by 23 experienced shoulder surgeons across 19 institutions.

View Article and Find Full Text PDF

Purpose: The purpose of the study was to describe the characteristics and demonstrate proof-of-concept and clinical use of a barium sulfate infused polypropylene radiopaque tissue marker for soft tissue localization and in vivo measurement of lengths and areas.

Methods: Marker mechanical properties were evaluated by tensile tests. Biocompatibility was evaluated following 8-12 weeks' implantation in a pig model.

View Article and Find Full Text PDF

Background: Glenohumeral osteoarthritis (OA) carries a spectrum of morphology and wear patterns of the glenoid surface exemplified by complex patterns such as glenoid biconcavity and acquired retroversion seen in the B2 glenoid. Multiple imaging methods are available for evaluation of the complex glenoid structure seen in B2 glenoids. The purpose of this article is to review imaging assessment of the type B2 glenoid.

View Article and Find Full Text PDF

Background: Nonspherical prosthetic humeral head designs have become increasingly popular as they better approximate the native shoulder anatomy and biomechanical properties and is supported by the existing literature. It remains to be seen how this will impact postoperative outcomes for total shoulder arthroplasty providing a justification for this review.

Methods: A review and synthesis of the literature on the subject of joint replacement in the native and prosthetic humeral head was performed.

View Article and Find Full Text PDF

Background: Use of 3-dimensional (3D) computed tomography (CT) preoperative planning and patient-specific instrumentation has been demonstrated to improve the accuracy of glenoid implant placement in total shoulder arthroplasty (TSA). The purpose of this study was to compare the accuracy of glenoid implant placement in primary TSA among different types of instrumentation used with the 3D CT preoperative planning.

Methods: One hundred and seventy-three patients with end-stage glenohumeral arthritis were enrolled in 3 prospective studies evaluating patient-specific instrumentation and 3D preoperative planning.

View Article and Find Full Text PDF

Background: The primary objectives of this study were to evaluate the ability of a posteriorly stepped augmented glenoid component, used in patients with primary glenohumeral osteoarthritis with B2 or B3 glenoid morphology, to correct preoperative retroversion and humeral head subluxation and to identify factors associated with radiographic radiolucency and patient-reported clinical outcomes.

Methods: We identified 71 shoulders with B2 or B3 glenoid morphology that underwent anatomic total shoulder arthroplasty with use of a posteriorly stepped augmented glenoid component and with a preoperative 3-dimensional computed tomography (3D-CT) scan and a minimum of 2 years of clinical and radiographic follow-up. The Penn Shoulder Score (PSS), shoulder range of motion, glenoid center-peg osteolysis, and postoperative version and humeral head subluxation were the main outcome variables of interest.

View Article and Find Full Text PDF

Background: Scapular notching is frequently observed following reverse total shoulder arthroplasty (rTSA), although the etiology is not well understood.

Methods: Twenty-nine patients with preoperative computed tomography (CT) scans who underwent rTSA with a Grammont design were evaluated after a minimum of 2 years of follow-up with video motion analysis (VMA), postoperative three-dimensional (3D) CT, and standard radiographs. The glenohumeral range of motion demonstrated by the VMA and the postoperative implant location on the CT were used in custom simulation software to determine areas of osseous impingement between the humeral implant and the scapula and their relationship to scapular notching on postoperative CT.

View Article and Find Full Text PDF

Background: Detection of postoperative component position and implant shift following total shoulder arthroplasty (TSA) can be challenging using routine imaging. The purpose of this study was to evaluate glenoid component position over time using 3-dimensional computed tomography (CT) analysis with minimum 2-year follow-up.

Methods: Twenty patients underwent primary TSA with sequential CT scanning of the shoulder: a preoperative study, an immediate postoperative study within 2 weeks of surgery, and a postoperative study performed at minimum 2-year follow-up (CT3).

View Article and Find Full Text PDF

Background: Walch defined the pathologic characteristics of glenohumeral osteoarthritis on the basis of patterns of glenoid morphology and humeral head subluxation. However, it is unclear how pathologic changes evolve over time. The purpose of this study was to determine whether there are common patterns of pathologic progression based on the Walch classification in primary glenohumeral osteoarthritis and if glenoid bone-loss patterns correlate with rotator cuff fatty infiltration.

View Article and Find Full Text PDF

Background: Osteoarthritis of the glenohumeral joint has typical patterns of deformity as described by Walch et al. However, more severe glenoid pathology may be difficult to classify. The purpose of this study was to use 3-dimensional computed tomography (3-D CT) imaging analysis to define common pathologic subtypes that can be differentiated from the current Walch classification.

View Article and Find Full Text PDF

Background: Inconsistent tension distribution may decrease the biomechanical properties of the rotator cuff tendon after double-row repair, resulting in repair failure. The purpose of this study was to compare the tension distribution along the repaired rotator cuff tendon among three double-row repair techniques.

Methods: In each of 42 fresh-frozen porcine shoulders, a simulated infraspinatus tendon tear was repaired by using 1 of 3 double-row techniques: (1) conventional double-row repair (no bridging suture); (2) transosseous-equivalent repair (bridging suture alone); and (3) compression double-row repair (which combined conventional double-row and bridging sutures).

View Article and Find Full Text PDF

The purpose of this study was to demonstrate feasibility of a clinical CT imaging and analysis technique to quantify regional variations in trabecular bone architecture and mineralization of glenoid bones. Specifically, our objective was to determine to what extent clinical CT imaging of intact upper extremities can describe variations of trabecular bone architectures at anatomic and peri-implant regions by comparing trabecular bone architectures as measured by high-resolution, micro CT imaging of same excised glenoid bones. Bone volume fraction (BVF), trabecular bone thickness (TbTh), number of trabecular bone (TbN), spacing (TbS), pattern factor (TbPf), bone surface area (BSA), and skeletal connectivity (Conn.

View Article and Find Full Text PDF

Purpose: Estimation of anterior glenoid bone loss is important for surgical decision-making. The purpose of this study was to describe a method for estimating anterior glenoid bone loss.

Methods: Thirty-nine cadaveric glenoids were digitized to obtain glenoid geometry.

View Article and Find Full Text PDF

Background: A non-spherical humeral head has been shown to influence kinematics and stability of the glenohumeral joint; yet, most prosthetic humeral head components are designed to be a perfect sphere. The effect of humeral head shape on prosthetic joint kinematics after total shoulder arthroplasty is not well understood. We hypothesized that prosthetic joint kinematics during humeral axial rotation is dependent on humeral head shape, regardless of joint conformity.

View Article and Find Full Text PDF

Stemless humeral fixation has become an alternative to traditional total shoulder arthroplasty, but metaphyseal fixation may be compromised by the quality of the trabecular bone that diminishes with age and disease, and augmentation of the fixation may be desirable. The authors hypothesized that a bone graft substitute (BGS) could achieve initial fixation comparable to polymethylmethacrylate (PMMA) bone cement. Fifteen fresh-frozen human male humerii were randomly implanted using a stemless humeral prosthesis, and metaphyseal fixation was augmented with either high-viscosity PMMA bone cement (PMMA group) or a magnesium-based injectable BGS (OsteoCrete; Bone Solutions Inc, Dallas, Texas) (OC group).

View Article and Find Full Text PDF

Background: Preoperative quantitative assessment of glenoid bone loss, selection of the glenoid component, and definition of its desired location can be challenging. Placement of the glenoid component in the desired location at the time of surgery is difficult, especially with severe glenoid pathological conditions.

Methods: Forty-six patients were randomly assigned to three-dimensional computed tomographic preoperative templating with either standard instrumentation or with patient-specific instrumentation and were compared with a nonrandomized group of seventeen patients with two-dimensional imaging and standard instrumentation used as historical controls.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to define the subscapularis tendon footprint anatomy in 3-dimensional (3D) perspective, report the incidence of tears, and classify the tear patterns prospectively during shoulder arthroscopic surgery.

Methods: The cadaveric study consisted of a pilot study that revealed 4 different bony facets by simple observation at the subscapularis attachment. The 3D footprint anatomy was digitally evaluated in 39 cadavers.

View Article and Find Full Text PDF

Background: With the advent of arthroscopy, more partial subscapularis tears are being recognized. The biomechanical effects of partial subscapularis tears are unknown, and there is no consensus as to their treatment. Therefore, the objective of this study was to evaluate and to quantify the changes in range of motion and glenohumeral kinematics for isolated subscapularis partial tears, combined subscapularis and supraspinatus tears, supraspinatus repair, and combined supraspinatus and subscapularis repair.

View Article and Find Full Text PDF

Purpose: Our purpose was to investigate the effect of supraspinatus tendon tear combined with anterior capsulolabral injury on glenohumeral joint biomechanics and to identify which structures should be repaired when both pathologic conditions are present.

Methods: Eight cadaveric shoulders were tested on a custom system. Five conditions were tested: intact supraspinatus full-thickness tear, supraspinatus tear combined with Bankart lesion, supraspinatus repair, and supraspinatus repair combined with Bankart repair.

View Article and Find Full Text PDF