Background: Procedural success and clinical outcomes after transcatheter aortic valve replacement (TAVR) have improved, but residual aortic regurgitation (AR) and new permanent pacemaker implantation (PPI) rates remain variable because of a lack of uniform periprocedural management and implantation.
Objectives: The Optimize PRO study evaluates valve performance and procedural outcomes using an "optimized" TAVR care pathway and the cusp overlap technique (COT) in patients receiving the Evolut PRO/PRO+ (Medtronic) self-expanding valves.
Methods: Optimize PRO, a nonrandomized, prospective, postmarket study conducted in the United States, Canada, Europe, Middle East, and Australia, is enrolling patients with severe symptomatic aortic stenosis and no pre-existing pacemaker.
Objectives: The purpose of this study was to evaluate the safety and efficacy of valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR) for stentless bioprosthetic aortic valves (SBAVs) and to identify predictors of adverse events.
Background: ViV TAVR in SBAVs is associated with unique technical challenges and risks.
Methods: Clinical records and computer tomographic scans were retrospectively reviewed for procedural complications, predictors of coronary obstruction, mortality, and echocardiographic results.
Background: Previously, we reported a 18% increased odds of ST-elevation myocardial infarction (STEMI) associated with each 7.1 µg/m(3) increase in PM2.5 concentration in the hour prior to MI onset.
View Article and Find Full Text PDFBackground: We and others have shown that increases in particulate air pollutant (PM) concentrations in the previous hours and days have been associated with increased risks of myocardial infarction, but little is known about the relationships between air pollution and specific subsets of myocardial infarction, such as ST-elevation myocardial infarction (STEMI) and non ST-elevation myocardial infarction (NSTEMI).
Methods: Using data from acute coronary syndrome patients with STEMI (n = 338) and NSTEMI (n = 339) and case-crossover methods, we estimated the risk of STEMI and NSTEMI associated with increased ambient fine particle (<2.5 um) concentrations, ultrafine particle (10-100 nm) number concentrations, and accumulation mode particle (100-500 nm) number concentrations in the previous few hours and days.
Background: Although echocardiography is commonly used to evaluate cardiac function after MI, CMR may provide more accurate functional assessment but has not been adequately compared with echo. The primary study objective was to compare metrics of left ventricular volumes and global and regional function determined by cardiac magnetic resonance (CMR) and echocardiography (echo) in patients (pts) with recent myocardial infarction (MI).
Methods: To compare CMR with echo, 47 consecutive patients (pts 70% male; mean age = 66 +/- 11 years) with MI >6 wks previously and scheduled for imaging evaluation were studied by both echo and CMR within 60 min of each other.