Orthopaedic implants and temporary osteosynthesis devices are commonly based on Titanium (Ti). For short-term devices, cell-material contact should be restricted for easy removal after bone healing. This could be achieved with anti-adhesive plasma-fluorocarbon-polymer (PFP) films created by low-temperature plasma processes.
View Article and Find Full Text PDFAntimicrobial coating of implant material with poly(hexamethylene biguanide) hydrochloride (PHMB) may be an eligible method for preventing implant-associated infections. In the present study, an antibacterial effective amount of PHMB is adsorbed on the surface of titanium alloy after simple chemical pretreatment. Either oxidation with 5% H O for 24 hr or processing for 2 hr in 5 M NaOH provides the base for the subsequent formation of a relatively stable self-assembled PHMB layer.
View Article and Find Full Text PDFBiomaterials should be bioactive in stimulating the surrounding tissue to accelerate the ingrowth of permanent implants. Chemical and topographical features of the biomaterial surface affect cell physiology at the interface. A frequently asked question is whether the chemistry or the topography dominates the cell-material interaction.
View Article and Find Full Text PDFBiomaterials can cause a chronic local inflammation called foreign body reaction, with formation of foreign body giant cells (FBGC) by monocyte/macrophage fusion. However, FBGC appearance and role for biomaterials with different physicochemical properties are not yet fully understood. This study aimed at examining FBGC and inflammatory cells after intramuscular implantation of poly(l-lactide-co-d/l-lactide) (PLA) as membranes and uncoated electro-spun fiber meshes or meshes with a positively charged plasma-polymer coating into rats.
View Article and Find Full Text PDFBackground: Biomaterial modifications-chemical and topographical-are of particular importance for the integration of materials in biosystems. Cells are known to sense these biomaterial characteristics, but it has remained unclear which physiological processes bio modifications trigger. Hence, the question arises of whether the dynamic of intracellular calcium ions is important for the characterization of the cell-material interaction.
View Article and Find Full Text PDFThe topographical and chemical surface features of biomaterials are sensed by the cells, affecting their physiology at the interface. When placed on titanium, we recently discovered osteoblasts attempted caveolae-mediated phagocytosis of the sharp-edged microstructures. This active, energy-consuming process resulted in decreased osteoblastic cell functions (e.
View Article and Find Full Text PDFCopper (Cu) could be suitable to create anti-infective implants based on Titanium (Ti), for example by incorporating Cu into the implant surface using plasma immersion ion implantation (Cu-PIII). The cytotoxicity of Cu might be circumvented by an additional cell-adhesive plasma polymerized allylamine film (PPAAm). Thus, this study aimed to examine in vivo local inflammatory reactions for Ti6Al4V implants treated with Cu-PIII (Ti-Cu), alone or with an additional PPAAm film (Ti-Cu-PPAAm), compared to untreated implants (Ti).
View Article and Find Full Text PDFACS Appl Mater Interfaces
March 2017
Topographical and chemical features of biomaterial surfaces affect the cell physiology at the interface and are promising tools for the improvement of implants. The dominance of the surface topography on cell behavior is often accentuated. Striated surfaces induce an alignment of cells and their intracellular adhesion-mediated components.
View Article and Find Full Text PDFMater Sci Eng C Mater Biol Appl
December 2016
Excellent osseointegration of permanent implants is crucial for the long lasting success of the implantation. To improve the osseointegrative potential, bio-inert titanium alloy surfaces (Ti6Al4V) are modified by plasma chemical oxidation (PCO®) of the titanium-oxide layer to a non-stoichiometric, amorphous calcium phosphate layer. The native titanium-oxide film measuring only a few nanometers is converted by PCO® to a thick porous calcium phosphate layer of about 10μm.
View Article and Find Full Text PDFA common method to derive both qualitative and quantitative data to evaluate osseointegration of implants is histomorphometry. The present study describes a new image reconstruction algorithm comparing the results of bone-to-implant contact (BIC) evaluated by means of µCT with histomorphometry data. Custom-made conical titanium alloyed (Ti6Al4V) implants were inserted in the distal tibial bone of female Sprague-Dawley rats.
View Article and Find Full Text PDFImplantation of biomaterials can cause complications often associated with inflammatory reactions. However, repeated evaluation of the implant site would be burdening for patients. Alternatively, blood examinations with analysis of inflammatory serum markers could potentially be useful to reflect the local cellular response for detection and/or prediction of inflammation-related complications.
View Article and Find Full Text PDFThe long-term stability and γ-sterilisability of bioactive layers is the precondition for the application of implants. Thus, aging processes of a microwave deposited, plasma polymerized allylamine nanofilm (PPAAm) with positively charged amino groups were evaluated concerning physicochemical characteristics and cell adhesion capacity over the course of one year. XPS, FT-IR, surface free energy, and water contact angle measurements elucidated not only the oxidation of the PPAAm film due to atmospheric oxygen reacting with surface free radicals but also the influence of atmospheric moisture during sample storage in ambient air.
View Article and Find Full Text PDFAn effective amount of the antiseptic agent PHMB cannot simply be placed on the surface of titanium alloys where hydrocarbons were removed by different purification procedures. Pre-treatment of Ti6Al4V specimen with 5% H2O2 in 24 h results in extra introduced -OH and -COOH groups as well as an adsorbed water film on the surface, which provide the base for the subsequent formation of a relatively stable and multi-layered PHMB film. The superficially adhering PHMB film produces no adverse effects on MG63 cells within a 48 h-cell culture, but promotes the initial attachment and spreading of the osteoblasts on the modified Ti6Al4V surface within 15 min.
View Article and Find Full Text PDFBy means of plasma polymerization, positively charged, nanometre-thin coatings can be applied to implant surfaces. The aim of the present study was to quantify the adhesion of human bone cells in vitro and to evaluate the bone ongrowth in vivo, on titanium surfaces modified by plasma polymer coatings. Different implant surface configurations were examined: titanium alloy (Ti6Al4V) coated with plasma-polymerized allylamine (PPAAm) and plasma-polymerized ethylenediamine (PPEDA) versus uncoated.
View Article and Find Full Text PDFCopper (Cu) could serve as antibacterial coating for Ti6Al4V implants. An additional cell-adhesive layer might compensate Cu cytotoxicity. This study aimed at in vitro and in vivo evaluation of low-temperature plasma treatment of Ti6Al4V plates with Ti/Cu magnetron sputtering (Ti6Al4V-Ti/Cu), plasma-polymerized ethylenediamine (Ti6Al4V-PPEDA), or both (Ti6Al4V-Ti/Cu-PPEDA).
View Article and Find Full Text PDFTopographical and chemical modifications of biomaterial surfaces both influence tissue physiology, but unfortunately little knowledge exists as to their combined effect. There are many indications that rough surfaces positively influence osteoblast behavior. Having determined previously that a positively charged, smooth titanium surface boosts osteoblast adhesion, we wanted to investigate the combined effects of topography and chemistry and elucidate which of these properties is dominant.
View Article and Find Full Text PDFSurface modification of Titanium (Ti) by low-temperature plasma influences cell-material interactions. Therefore, this study aimed at examining serum cytokine levels and associations after intramuscular implantation (n = 8 rats/group) of Ti-plates with Plasma Polymerized Allyl Amine (Ti-PPAAm), Plasma Polymerized Acrylic Acid (Ti-PPAAc), and without such layers (Ti-Controls). Pro-inflammatory (IL-2, IFNγ, IL-6) and anti-inflammatory (IL-4, IL-10, IL-13) cytokines were measured weekly for 56 days.
View Article and Find Full Text PDFNew developments of antimicrobial implant surfaces doped with copper (Cu) ions may minimize the risk of implant-associated infections. However, experimental evaluation of the Cu release is influenced by various test parameters. The aim of our study was to evaluate the Cu release characteristics in vitro according to the storage fluid and surface roughness.
View Article and Find Full Text PDFImplantation of biomaterials like titanium (Ti) causes inflammatory reactions possibly affecting implant functionality. Surface modifications could improve biocompatibility and functionality of implants. Biomembrane-derived phospholipids might be useful as implant coating due to their biomimetic properties.
View Article and Find Full Text PDFPurpose: To improve orthopedic implant ingrowth, knowledge of the effect of chemical surface modifications on vital cell function in vitro is of importance. Early in our investigations we recognized that amino groups, positively charged via plasma polymerized allylamine, increased cell growth and the actin-filament formation in the initial cell-material contact phase. To gain insight into continuous vital cell behavior on this plasma polymer layer, here we present the metabolic activity of osteoblasts and their time-dependent adhesion using the sensor chip technology.
View Article and Find Full Text PDFAdhesion and spreading of cells on biomaterials are integrin-mediated processes. But recent findings indicate a key role of the cell membrane associated matrix substance hyaluronan (HA) in interface interactions. Because HA is a negatively charged molecule we assume that a biomaterial surface with an opposed charge could boost the first contact of the cell to the surface.
View Article and Find Full Text PDFThe crucial factor of metal implant ingrowth in the bone is the rapid cellular acceptance. Therefore, the knowledge about additionally used adhesion mechanisms of osteoblasts, like their negatively charged hyaluronan coat, generates new surface functionalization strategies. Here, titanium was coated with a very thin, adherent, cross-linked, pinhole- and additive-free allylamine plasma polymer layer (PPAAm) resistant to hydrolysis and delamination and equipped with a high density of positively charged amino groups.
View Article and Find Full Text PDF