Publications by authors named "Binling Zhu"

The growing popularity of e-cigarettes has raised significant concerns about the safety and potential abuse of these products. Compounds originally used in the medical field, such as etomidate, metomidate, and isopropoxate, have been illegally added to e-liquids, posing substantial risks to consumer health, and facilitating the misuse of illicit drugs. To address these concerns, this study developed a rapid and efficient method for detecting etomidate, metomidate, and isopropoxate in e-liquids using thermal desorption electrospray ionization coupling triple quadrupole mass spectrometry (TD-ESI/MS/MS).

View Article and Find Full Text PDF

Nitrogen and sulfur co-doped carbon dots (N, S-CDs) were prepared for dual-channel ratiometric fluorescence determination of mercury ions (Hg). The dual-emission N, S-CDs were synthesized using a simple one-pot hydrothermal treatment. When excited with visible light, N,S-CDs exhibited two emission peaks at 390 and 500 nm.

View Article and Find Full Text PDF

Goose circovirus (GoCV), a potential immunosuppressive virus possessing a circular single-stranded DNA genome, is widely distributed in both domesticated and wild geese. This virus infection causes significant economic losses in the waterfowl industry. The codon usage patterns of viruses reflect the evolutionary history and genetic architecture, allowing them to adapt quickly to changes in the external environment, particularly to their hosts.

View Article and Find Full Text PDF

With the rapid development of synthetic drugs, novel piperazine derivatives, as an increasingly important class of new psychoactive substances (NPS), have attracted global attention owing to their increasing demand in the illicit drug market. In this study, ten piperazine derivatives were analyzed in urine samples after pre-treatment with ultrasound-assisted low-density solvent dispersive liquid-liquid microextraction (UA-LDS-DLLME) combined with gas chromatography-tandem mass spectrometry (GC-MS/MS). This simple approach involved the use of urine samples (1 mL) adjusted to pH 12, which was added to 100 µL of n-hexane and subjected to ultrasonication for 3 min to completely disperse the sample in the n-hexane solution.

View Article and Find Full Text PDF

Ephedrine/pseudoephedrine (EPH) is the most common precursor for the manufacture of methamphetamine and is controlled within China via criminal law and government regulations. Therefore, it is of great significance to systematically study the cases of illicit production of EPH in order to aid timely investigation into the production of precursor drugs. According to the literature, there are no comprehensive case studies on the illicit production of EPH.

View Article and Find Full Text PDF

Recently, gamma-hydroxybutyrate (GHB) was determined in "Kawa Trendy Drink" which was labeled as a functional beverage containing gamma-aminobutyric acid and quickly became popular in various club in China. GHB has a strong sedative effect and is often used as a date rape drug and euphoriant in drug-facilitated sexual assaults. However, it is believed that same beverages themselves contain natural GHB.

View Article and Find Full Text PDF

Fluorescence imaging technology has gradually become a new and promising tool for visualization detection. Because it can provide real-time sub-cellular resolution imaging results, it can be widely used in the field of biological detection and medical detection and treatment. However, due to the limited imaging depth (1-2 mm) and self-fluorescence background of tissue emitted in the visible region (400-700 nm), it fails to reveal biological complexity in deep tissues.

View Article and Find Full Text PDF

A novel microextraction technique based on ultrasound-assisted low-density solvent dispersive liquid-liquid microextraction (UA-LDS-DLLME) had been applied for the determination of 4 designer benzodiazepines (phenazepam, diclazepam, flubromazepam and etizolam) in urine samples by gas chromatography- triple quadrupole mass spectrometry (GC-QQQ-MS). Ethyl acetate (168μL) was added into the urine samples after adjusting pH to 11.3.

View Article and Find Full Text PDF

A novel microextraction technique based on ultrasound-assisted low-density solvent dispersive liquid-liquid microextraction (UA-LDS-DLLME) has been developed for the determination of multiple drugs of abuse in biological samples by gas chromatography-triple quadrupole mass spectrometry (GC-QQQ-MS). A total of 100 µL of toluene as extraction solvent was dropped into the sample solution. Then the mixture was sonicated drastically in an ultrasonic bath for 3 min with occasional manual shaking to form a cloudy suspension.

View Article and Find Full Text PDF

Two microextraction techniques based on hollow fiber liquid-phase microextraction (HF-LPME) and ultrasound-assisted low-density solvent dispersive liquid-liquid microextraction (UA-LDS-DLLME) had been applied for the determination of drugs of abuse (methamphetamine, amphetamine, 3,4-methylenedioxymethamphetamine, 3,4-methylenedioxyamphetamine, methcathinone, ketamine, meperidine, and methadone) in urine and blood samples by gas chromatography-mass spectrometry. Parameters affecting extraction efficiency have been investigated and optimized for both methods. Under the optimum conditions, linearities were observed for all analytes in the range 0.

View Article and Find Full Text PDF

Recently a new type of mixed drug oral solution has become prevalent in China, the identification and quantitative inspection of which are demanded in conviction and sentencing as well as drug intelligence. In 2013, inspection was carried out on 86 bottles of substances seized in 13 cases with the adoption of GC-MS methodology for qualitative identification and GC-FID for quantitative identification. 94.

View Article and Find Full Text PDF

Objective: Disk solid phase extraction (SPE) was assessed for tramadol hydrochloride from serum.

Methods: The SPE was performed with SPEC C18AR/MP3 Disk SPE cartridge, offering hydrophobic C18 and strong cation ionic exchange interactions for the analytes, before being added into extraction column, 1 mL serum was diluted by 2 mL 0.1 mol/L phosphate buffer solution (pH 6) and the eluent was ethyl acetate containing 2% ammonia.

View Article and Find Full Text PDF