Publications by authors named "Bingzhong Fu"

A high-speed vacuum ultraviolet monochromator is developed for the HL-2A tokamak through the introduction of a novel channel electron multiplier in a modified Seya-Namioka spectrometer. A good signal to noise ratio of above 2000 is attained in the development phase of the system with typical operating parameters for observing routine HL-2A plasmas. The wavelength calibration is performed using characteristic line emissions from a hollow cathode light source with helium and argon discharges.

View Article and Find Full Text PDF

A novel 16-channel fixed frequency Doppler backward scattering (DBS) reflectometer system has been developed on the HL-2A tokamak. This system is based on the filter-based feedback loop microwave source (FFLMS) technique, which has lower phase noise and lower power variation compared with present tunable frequency generation and comb frequency array generation techniques [J. C.

View Article and Find Full Text PDF

A space-resolved grazing-incidence flat-field extreme ultraviolet (EUV) spectrometer has been developed in the HL-2A tokamak to measure vertical impurity emission profiles with simultaneous spectral, temporal, and spatial resolution. The spectrometer working in the wavelength range of 30-500 Å has been equipped with a gold-coated varied-line-spacing holographic grating with curvature of 5606 mm and a back illuminated charge-coupled device with size of 6.6 × 26.

View Article and Find Full Text PDF

A grazing-incidence flat-field extreme ultraviolet (EUV) spectrometer has been newly developed in HL-2A tokamak. Typical spectral lines are observed from intrinsic impurities of carbon, oxygen, iron, and extrinsic impurity of helium in the wavelength range of 20 Å-500 Å. Bremsstrahlung continuum is measured at different electron densities of HL-2A discharges to calibrate absolute sensitivity of the EUV spectrometer system and to measure effective ionic charge, Z(eff).

View Article and Find Full Text PDF

A 1 m normal incidence vacuum ultraviolet (VUV) spectrometer has been developed for spatial distribution measurement of edge impurity line emission in the wavelength range of 300-3200 A on HL-2A tokamak. A vertical profile of the impurity line emission is measured with a space-resolved slit placed between an entrance slit and a grating of the spectrometer. Two concave 1200 grooves/mm gratings blazed at 800 and 1500 A are set on a rotatable holder in the spectrometer, which gives wavelength dispersion of 0.

View Article and Find Full Text PDF