Aim: This in-vitro study aimed to evaluate the degree of conversion (DC) of dual-cured luting cement (Bifix QM, VOCO) and flowable composite (Grandio Flow, VOCO) under lithium disilicate glass-ceramic (IPS e.max CAD, Ivoclar Vivadent) and hybrid ceramic (Grandio Blocs, VOCO; Cerasmart, GC) CAD-CAM blocks with different thicknesses.
Materials And Methods: Contrast ratio (CR), translucency (TP, TP), and opalescence (OP) parameters of 30 disc-shaped CAD-CAM blocks (n = 5) prepared with two different thicknesses (1.
The use of multivitamins has become widespread globally, yet there is a scarcity of studies investigating their impact on resin composite restorations. This study aimed to evaluate the effect of an effervescent multivitamin tablet on micro-hybrid dental resin composites' surface roughness and color. Fifty disc-shaped samples (8 × 2 mm, shade A2; = 10) were prepared and polished using five different micro-hybrid resin composites (Pergamon, Dentac, Turkey; Estelite Posterior, Tokuyama, Japan; Geanial Anterior, GC, Japan; Charisma Opal, Kulzer, Germany; Beautifil II, Shofu, USA).
View Article and Find Full Text PDFThe aim of this study was to demonstrate the vertical and volumetric wear characteristics of CAD/CAM materials. The microhardness and color stability were evaluated. A polymer infiltrated ceramic network CAD/CAM block, resin nanoceramic CAD/CAM blocks, a resin composite, and enamel tissue were investigated.
View Article and Find Full Text PDFThis in vitro study aimed to compare the microleakage and marginal integrity of methacrylate/ormocer-based bulk-fill composite (BFC) restorations used in cervical marginal relocation with two different layering thicknesses in mesio-occlusal-distal (MOD) cavities exposed to thermo-mechanical loading. Standard MOD cavities were prepared in 60 mandibular molars and assigned into three groups: x-tra fil/AF + x-tra base/XB, Tetric N-Ceram Bulk Fill/TNB + Tetric N-Flow Bulk Fill/TFB, and Admira Fusion x-tra/AFX + Admira Fusion x-base/AFB. Each group was further divided into two subgroups (2 mm and 4 mm) based on the thickness of flowable BFCs ( = 10).
View Article and Find Full Text PDFPurpose: To evaluate color differences in repair of indirect ceramic and resin nanoceramic CAD/CAM blocks with two universal shade composites after different surface preparations.
Materials And Methods: 120 samples were prepared from IPS Empress and GC Cerasmart270 CAD/ CAM blocks and thermocycled (5000 cycles, 5°C-55°C). Initial colors of sample surfaces were measured using a spectrophotometer.
Background/purpose: Studies suggested that presence and size of overhanging restoration margins play role in alveolar bone loss. The aim of this study was to determine the prevalence and distribution of overhanging approximal restorations, to evaluate the effect of presence and size of overhang on bone loss using cone beam computed tomography (CBCT) reformatted panoramic images, and to encourage the use of CBCT in retrospective studies on restorative dentistry.
Materials And Methods: CBCT images of 382 patients with approximal restorations were included in the study.
Single-shade universal resin composites (SsURC) are preferred in clinical practice to reduce time for shade selection and obtain good esthetic results. In this study, the static mechanical properties of seven new SsURCs were investigated, their spectral analyzes were performed and scanning electron microscopy (SEM) evaluations were presented. Charisma Diamond One/DO, Admira Fusion x-tra/AFX, Omnichroma/OC, OptiShade/OS, Essentia Universal/EU, Zenchroma/ZC, Vittra APS Unique/VU were used in a three-point bending test to determine flexural strength (FS) and elastic modulus (EM); Vickers micro-hardness (VHN) and hardness-ratio (HR) were performed with a micro-hardness tester from top/bottom after 24-h/15-days of storage in distilled water at 37 °C (±1 °C).
View Article and Find Full Text PDFObjectives: This study was aimed to determine the effects of modeling resins on the surface microhardness of composites.
Materials And Methods: Six resin-based composites (Charisma Smart, Estellite Asteria, CeramX-One SphereTEC, Admira Fusion, Filtek Ultimate, and Clearfil Majesty Es-2) and three wetting agents (Modeling Liquid, Composite Primer, and Modeling Resin) were investigated. In all, 240 specimens were prepared, and wetting agents were applied prior to light curing in the experimental groups.
Dental health care workers are subjected to various infectious disease agents that are present in patients' saliva and blood which make infection control and universal prevention methods indispensable to the dental practice given that some of these diseases cause loss of work and time for dental staff and patients; some of them cause serious morbidity; and some of them currently have a poor prognosis and no effective treatments. Although dental radiographic procedures are not invasive, and there are no incidents such as injuries caused by dental instruments, they are a potential infection source because of contamination with saliva and blood, and comprehensive infection control procedures also apply to the radiology clinic. In addition, contact with a large number of patients in dental schools and clinics in a short period of time, and the fact that radiographic procedures are performed in the same environment as other dental procedures in dental offices increase the significance of infection control in dental radiology.
View Article and Find Full Text PDFThe aim of this study was to assess the effect of zirconia core thickness on the biaxial flexural strength values of zirconia-porcelain bilayered discs. A total of 60 discs with 0.3, 0.
View Article and Find Full Text PDFIntroduction: The aim of this study was to evaluate observer variations and observer reproducibility in the interpretation of periapical health using the Strindberg system, the periapical index (PAI), and the probability index for radiologic assessment of periapical health.
Methods: Four observers read digital periapical images to evaluate the periapical health of 200 root-filled teeth. Each observer evaluated a tooth twice by using the Strindberg system, twice by using the PAI, and twice by using the probability index.
Introduction: We compared the apical extrusion of sodium hypochlorite delivered with a 27-G needle, self-adjusting file (SAF), passive ultrasonic irrigation, or the EndoVac system (SybronEndo, Orange, CA) during the instrumentation and final irrigation of root canals.
Methods: Matched paired single-canal teeth were divided into 8 groups. The experimental groups were needle irrigation size #30 (NI30) and #50 (NI50), SAF size #30 (SAF30) and #50 (SAF50), passive ultrasonic irrigation size #30 (PUI30) and #50 (PUI50), and EndoVac size #30 (EV30) and #50 (EV50).
Statement Of Problem: The ability of dental technician students to match tooth shade with the Vita 3D-Master shade guide and Toothguide Training Box has not been investigated.
Purpose: The purpose of this study was to evaluate and compare the shade-matching ability of dental technician students and graduate dentists using the Vita 3D-Master shade guide.
Material And Methods: Twenty-nine dental technician students (DTS group) and 30 graduate dentists (GD group) participated in this study.
Statement Of Problem: The influence of the thickness of dentin and core porcelain, and the glazing procedure on the color of computer-aided design and computer-aided manufacturing ceramic restorations has not been investigated.
Purpose: This study evaluated the influence of the thickness of dentin and core porcelain and glazing on the color of fully sintered zirconia ceramic restorations.
Material And Methods: Fully sintered zirconia core material was cut into 90 specimens of 0.
Objective: To evaluate tensile bond strengths of 2 dentin bonding agents containing solvents on Nd:YAG and Er,Cr:YSGG laser-etched dentin surface.
Method And Materials: Occlusal enamel of 146 molars was removed, and exposed surfaces were ground with a diamond bur to produce bur-cut dentin surfaces. Of those teeth, 120 were assigned to 3 groups of 40 samples in which dentin was conditioned with Er,Cr:YSGG laser, Nd:YAG laser, and 37% orthophosphoric acid (control).