Measuring low light absorption with combined uncertainty <1 per mil (‰) is crucial for many applications. Popular cavity ring-down spectroscopy can provide ultrahigh precision, below 0.01‰, but its accuracy is often worse than 5‰ due to inaccuracies in light intensity measurements.
View Article and Find Full Text PDFWe present the results of the spectral line-shape study of the first measurement of the extremely weak (7-0) band of the CO molecule. Measurements were done with a highly sensitive cavity ring-down spectrometer. Collisional narrowing, analyzed in terms of speed-dependent effects, was observed for the first time for transitions with line intensities below 2⋅10 cm/molecule at 296 K.
View Article and Find Full Text PDFSpectrochim Acta A Mol Biomol Spectrosc
December 2023
The air-broadened lines from the oxygen B band were measured for the first time in controlled laboratory conditions with a high signal-to-noise ratio using frequency-stabilized cavity ring-down spectroscopy (FS-CRDS) referenced to the optical frequency comb. Spectra measured at various pressures and temperatures were analyzed with an advanced line-shape model, considering the speed-dependence of collisional broadening and shift, and the effect of velocity-changing collisions. The temperature dependence of collisional broadening and shift is determined, whereas no significant temperature dependence of speed-dependent parameters and Dicke narrowing was observed.
View Article and Find Full Text PDFIntensities of 14 lines in the sixth overtone (7-0) band of carbon monoxide (12C16O) are measured in the visible range between 14 300 and 14 500 cm-1 using a frequency-stabilized cavity ring-down spectrometer. This is the first observation of such a high and weak overtone spectrum of the CO molecule. A theoretical model is constructed and tested based on the use of a high accuracy ab initio dipole moment curve and a semi-empirical potential energy curve.
View Article and Find Full Text PDFIntensities of lines in the near-infrared second overtone band (3-0) of ^{12}C^{16}O are measured and calculated to an unprecedented degree of precision and accuracy. Agreement between theory and experiment to better than 1‰ is demonstrated by results from two laboratories involving two independent absorption- and dispersion-based cavity-enhanced techniques. Similarly, independent Fourier transform spectroscopy measurements of stronger lines in this band yield mutual agreement and consistency with theory at the 1‰ level.
View Article and Find Full Text PDFWe present the results of direct measurements of the line mixing parameters for two pairs of overlapping transitions at the band head of the oxygen B band. Measurements were performed with the frequency-stabilized cavity ring-down spectrometer assisted by an optical frequency comb. The recorded spectra were analyzed with line profiles comprising speed dependence, Dicke narrowing, and line mixing.
View Article and Find Full Text PDFFrequency-based cavity mode-dispersion spectroscopy (CMDS), previously applied for Doppler-limited molecular spectroscopy, is now employed for the first time for saturation spectroscopy. Comparison with two intensity-based, cavity-enhanced absorption spectroscopy techniques, i.e.
View Article and Find Full Text PDFA spectroscopic method free from systematic errors is desired for many challenging applications of gas detection. Although existing cavity-enhanced techniques exhibit very high precision, their accuracy strongly depends on propagation of the light amplitude through an optical system and its detection. Here, we demonstrate that the frequency-based molecular dispersion spectroscopy, involving sub-Hz-level precision in frequency measurements of optical cavity resonances, leads to sub-per-mille accuracy and a wide dynamic range, both previously unattainable by any other spectroscopic technique.
View Article and Find Full Text PDFThe response of an optical cavity to incomplete extinction of nearly resonant incident light was experimentally examined. Measurements were performed using a Pound-Drever-Hall-locked frequency-stabilized cavity ring-down spectrometer (CRDS) that allowed the laser frequency detuning from the cavity resonance center to be controlled at Hz-level resolution. It is shown that an insufficient laser light extinction ratio combined with a phase shift and frequency detuning may lead to non-exponential cavity pumping and decay signals.
View Article and Find Full Text PDFAtmospheric CO(2) concentrations are being closely monitored by remote sensing experiments which rely on knowing line intensities with an uncertainty of 0.5% or better. Most available laboratory measurements have uncertainties much larger than this.
View Article and Find Full Text PDFCornelian cherry (Cornus mas L.) fruits have been used in traditional cuisine and in folk medicine in various countries. This study was conducted to evaluate the constituents and impact of cornelian cherry (C.
View Article and Find Full Text PDFDual-drive Mach-Zehnder modulators were utilized to produce power-leveled optical frequency combs (OFCs) from a continuous-wave laser. The resulting OFCs contained up to 50 unique frequency components and spanned more than 200 GHz. Simple changes to the modulation frequency allowed for agile control of the comb spacing.
View Article and Find Full Text PDFThe purpose of the research was to study kindergarteners' exposition to environmental tobacco smoke (ETS) in houses. Social and economical factors were checked for the improper behavior of grown-up household. Material for the research were data collected from questionnaires filled by children's parents.
View Article and Find Full Text PDFWe present a line-shape analysis of the rovibronic R1 Q2 transition of the oxygen B band resolved by the Pound-Drever-Hall-locked frequency-stabilized cavity ring-down spectroscopy technique in the low pressure range. The frequency axis of the spectra is linked by the ultra-narrow diode laser to the optical frequency comb in order to measure the absolute frequency at each point of the recorded spectra. Experimental spectra are fitted with various line-shape models: the Voigt profile, the Galatry profile, the Nelkin-Ghatak profile, the speed-dependent Voigt profile, and the speed-dependent Nelkin-Ghatak profile with quadratic and hypergeometric approximations for the speed dependence of collisional broadening and shifting.
View Article and Find Full Text PDFJ Steroid Biochem Mol Biol
November 2013
The 20-hydroxyecdysone receptor (EcR) is a transcription factor belonging to the nuclear receptor superfamily. Together with the ultraspiracle nuclear receptor (Usp) it coordinates critical biological processes in insects such as development and reproduction. EcR and its ligands are used in commercially available ecdysone-inducible expression systems and are considered to be artificial gene switches with potential therapeutic applications.
View Article and Find Full Text PDFJ Steroid Biochem Mol Biol
November 2012
The ultraspiracle protein (Usp), together with an ecdysone receptor (EcR) forms a heterodimeric ecdysteroid receptor complex, which controls metamorphosis in Drosophila melanogaster. Although the ecdysteroid receptor is considered to be a source of elements for ecdysteroid inducible gene switches in mammals, nothing is known about posttranslational modifications of the receptor constituents in mammalian cells. Up until now there has been no study about Usp sumoylation.
View Article and Find Full Text PDFWe present a laser absorption technique to measure the saturation vapour pressure of hexagonal ice. This method is referenced to the triple-point state of water and uses frequency-stabilized cavity ring-down spectroscopy to probe four rotation-vibration transitions of at wavenumbers near 7180 cm(-1). Laser measurements are made at the output of a temperature-regulated standard humidity generator, which contains ice.
View Article and Find Full Text PDFFrequency-stabilized cavity ring-down spectroscopy (FS-CRDS) was employed to measure air-broadened CO(2) line shape parameters for transitions near 1.6 μm over a pressure range of 6.7-33 kPa.
View Article and Find Full Text PDFWe describe a high sensitivity and high spectral resolution laser absorption spectrometer based upon the frequency-stabilized cavity ring-down spectroscopy (FS-CRDS) technique. We used the Pound-Drever-Hall (PDH) method to lock the probe laser to the high-finesse ring-down cavity. We show that the concomitant narrowing of the probe laser line width leads to dramatically increased ring-down event acquisition rates (up to 14.
View Article and Find Full Text PDFLymphocytes from 26 patients with primary gout were typed for eighteen antigens from A and B loci. An increased "relative risk" of the disease was established in patients carrying antigen HLA-B14, but the correlation is not sufficient for using HLA typing as a diagnostic tool in the gout. Nevertheless HLA-B14 seems to be one of the genetic factors which predispose to the appearance of the articular lesions.
View Article and Find Full Text PDF