Introduction: Instant messaging applications (MAs) represent a major component of modern telecommunications for data transmission. During overseas deployments, military doctors increasingly rely on MAs due to their availability and the urgent need to obtain advice from specialists for optimal patient management. In this study, we aimed to describe and analyze the context and usage characteristics of these MAs for transmitting medical data by military general practitioners (GPs) during overseas missions.
View Article and Find Full Text PDFIn model-based medical image analysis, three relevant features are the shape of structures of interest, their relative pose, and image intensity profiles representative of some physical properties. Often, these features are modelled separately through statistical models by decomposing the object's features into a set of basis functions through principal geodesic analysis or principal component analysis. However, analysing articulated objects in an image using independent single object models may lead to large uncertainties and impingement, especially around organ boundaries.
View Article and Find Full Text PDFCerebral palsy, a common physical disability in childhood, often causes abnormal patterns of movement and posture. To better understand the pathology and improve rehabilitation of patients, a comprehensive bone shape analysis approach is proposed in this article. First, a group analysis is performed on a clinical MRI dataset using two state-of-the-art shape analysis methods: ShapeWorks and a voxel-based method relying on Advanced Normalization Tools (ANTs) registration.
View Article and Find Full Text PDFMorphological and diagnostic evaluation of pediatric musculoskeletal system is crucial in clinical practice. However, most segmentation models do not perform well on scarce pediatric imaging data. We propose a new pre-trained regularized convolutional encoder-decoder network for the challenging task of segmenting heterogeneous pediatric magnetic resonance (MR) images.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
July 2022
Image-based diagnosis routinely depends on more that one image modality for exploiting the complementary information they provide. However, it is not always possible to obtain images from a secondary modality for several reasons such as cost, degree of invasiveness and non-availability of scanners. Three-dimensional (3D) morphable models have made a significant contribution to the field of medical imaging for feature-based analysis.
View Article and Find Full Text PDFClinical diagnosis of the pediatric musculoskeletal system relies on the analysis of medical imaging examinations. In the medical image processing pipeline, semantic segmentation using deep learning algorithms enables an automatic generation of patient-specific three-dimensional anatomical models which are crucial for morphological evaluation. However, the scarcity of pediatric imaging resources may result in reduced accuracy and generalization performance of individual deep segmentation models.
View Article and Find Full Text PDFBackground: Real-time sequences allow functional evaluation of various joint structures during a continuous motion and help understand the pathomechanics of underlying musculoskeletal diseases.
Purpose: To assess and compare the image quality of the two most frequently used real-time sequences for joint dynamic magnetic resonance imaging (MRI), acquired during finger and ankle joint motion.
Material And Methods: A real-time dynamic acquisition protocol, including radiofrequency (RF)-spoiled and balanced steady-state free precession (bSSFP) sequences, optimized for temporal resolution with similar spatial resolution, was performed using a 3.
Comput Assist Surg (Abingdon)
December 2022
The goal of this study was to assess and compare the precision and accuracy of nine and seven methods usually used in Computer Assisted Orthopedic Surgery (CAOS) to estimate respectively the Knee Center (KC) and the Frontal Plane (FP) for the determination of the HKA angle (HKAA). An in-vitro experiment has been realized on thirteen cadaveric lower limbs. A CAOS software application was developed and allowed the computation of the HKAA according to these nine KC and seven FP methods.
View Article and Find Full Text PDFObjective: Statistical shape models (SSMs) are a popular tool to conduct morphological analysis of anatomical structures which is a crucial step in clinical practices. However, shape representations through SSMs are based on shape coefficients and lack an explicit one-to-one relationship with anatomical measures of clinical relevance. While a shape coefficient embeds a combination of anatomical measures, a formalized approach to find the relationship between them remains elusive in the literature.
View Article and Find Full Text PDFCurrent lower limb musculoskeletal (MSK) models focus on sagittal plane kinematics. However, abnormal gait is typically associated with sagittal plane motions crossing into other planes, limiting the use of current MSK models. The purpose of this study was twofold, first, to extend the capability of a full-body MSK model from the literature to include frontal knee plane kinematics during healthy gait, and second, to propose and implement a realistic muscle discretization technique.
View Article and Find Full Text PDFIntroduction: Ulnar tunnel syndrome at the elbow is a common pathology. The ultrasound cross-sectional area is a well-known metric widely accepted in radiology for the description of nerve entrapment. However, the pathological cut-off value remains challenging.
View Article and Find Full Text PDFDynamic magnetic resonance imaging (MRI) is a non-invasive method that can be used to increase the understanding of the pathomechanics of joints. Various types of real-time gradient echo sequences used for dynamic MRI acquisition of joints include balanced steady-state free precession sequence, radiofrequency-spoiled sequence, and ultra-fast gradient echo sequence. Due to their short repetition time and echo time, these sequences provide high temporal resolution, a good signal-to-noise ratio and spatial resolution, and soft tissue contrast.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
July 2019
Objective: To illustrate (a) whether a statistical shape model (SSM) augmented with anatomical landmark set(s) performs better fitting and provides improved clinical relevance over non-augmented SSM and (b) which anatomical landmark set provides the best augmentation strategy for predicting the glenoid region of the scapula.
Methods: Scapula SSM was built using 27 dry bone CT scans and augmented with three anatomical landmark sets (16 landmarks each) resulting in three augmented SSMs (aSSM, aSSM, aSSM). The non-augmented and three augmented SSMs were then used in a non-rigid registration (regression) algorithm to fit to six external scapular shapes.
Prediction of complete and premorbid scapular anatomy is an important aspect of successful shoulder arthroplasty surgeries to treat glenohumeral arthritis and which remains elusive in the current literature. We proposed to build a statistical shape model (SSM) of the scapula and use it to build a framework to predict a complete scapular shape from virtually created scapular bone defects. The bone defects were synthetically created to imitate bone loss in the glenoid region and missing bony part in inferior and superior scapular regions.
View Article and Find Full Text PDFChanges in lower-extremity bone morphology are potential mid- to long-term secondary consequences of cerebral palsy (CP), affecting activity. Little is known about the 3-D morphology of lower-extremity bones in children with CP and the association with gait deviations. The main aim of this study was to describe and compare 3-D lower-extremity bone morphology in ambulant children with unilateral or bilateral CP.
View Article and Find Full Text PDFThe purpose of this study was to determine whether optimal epiphyseal screw length could be predicted with reference to a given diaphyseal screw length when fixating a plate to the anterior surface of the distal radius. Computerized tomography scans of 40 wrists of 28 men and 12 women were semi-automatically segmented. A virtual anterior plate model was fixed to the distal radius.
View Article and Find Full Text PDFComput Methods Biomech Biomed Engin
May 2019
The gleno-humeral (GH) rotation centre is typically estimated using predictive or functional methods, however these methods may lead to location errors. This study aimed at determining a location error threshold above which statistically significant changes in the values of kinematic and kinetic GH parameters occur. The secondary aims were to quantify the effects of the direction of mislocation (X, Y or Z axis) of the GH rotation centre on GH kinematic and kinetic parameters.
View Article and Find Full Text PDFIn this paper, we propose a method for non-invasively measuring three-dimensional in vivo kinematics of the ankle joint from a dynamic MRI acquisition of a single range-of-motion cycle. The proposed approach relies on an intensity-based registration method to estimate motion from multi-plane dynamic MRI data. Our approach recovers not only the movement of the skeleton, but also the possibly non-rigid temporal deformation of the joint.
View Article and Find Full Text PDFAims: The aim of this study was to report the metrological qualities of techniques currently used to quantify skeletal muscle volume and 3D shape in healthy and pathological muscles.
Methods: A systematic review was conducted (Prospero CRD42018082708). PubMed, Web of Science, Cochrane and Scopus databases were searched using relevant keywords and inclusion/exclusion criteria.
Purpose: To report evidence for the concurrent validity and reliability of dynamic MRI techniques to evaluate in vivo joint and muscle mechanics, and to propose recommendations for their use in the assessment of normal and impaired musculoskeletal function.
Materials And Methods: The search was conducted on articles published in Web of science, PubMed, Scopus, Academic search Premier, and Cochrane Library between 1990 and August 2017. Studies that reported the concurrent validity and/or reliability of dynamic MRI techniques for in vivo evaluation of joint or muscle mechanics were included after assessment by two independent reviewers.
Annu Int Conf IEEE Eng Med Biol Soc
July 2017
Subject-specific musculoskeletal models can predict accurate joint and muscle biomechanics thereby helping clinicians and surgeons. Current modeling strategies do not incorporate accurate subject-specific muscle parameters. This study reports a statistical shape model (SSM) based method to predict subject-specific muscle attachment regions on shoulder bones and illustrates the concurrent validity of the predictions.
View Article and Find Full Text PDFIn this study we have described the use of statistical shape modeling (SSM) technique in evaluating the morphological variation of shoulder bones from a South African population. The anatomical landmark selections were carried out, followed by the registration of the meshes which were validated before establishing the dense correspondence. The SSMs were built and average shape comparison from each side for each bone were made in order to evaluate handedness.
View Article and Find Full Text PDF