This study investigated the dosimetric differences in treatment plans from flattened and flattening filter-free (FFF) beams from the TrueBeam System. A total of 104 treatment plans with static (sliding window) intensity-modulated radiotherapy beams and volumetric-modulated arc therapy (VMAT) beams were generated for 15 patients involving three cancer sites. In general, the FFF beam provides similar target coverage as the flattened beam with improved dose sparing to organ-at-risk (OAR).

View Article and Find Full Text PDF

ViewRay is a novel MR-guided radiotherapy system capable of imaging in near real-time at four frames per second during treatment using 0.35T field strength. It allows for improved gating techniques and adaptive radiotherapy.

View Article and Find Full Text PDF

Purpose. To achieve rapid automated delineation of gross target volume (GTV) and to quantify changes in volume/position of the target for radiotherapy planning using four-dimensional (4D) CT. Methods and Materials.

View Article and Find Full Text PDF

ViewRay, a novel technology providing soft-tissue imaging during radiotherapy is investigated for treatment planning capabilities assessing treatment plan dose homogeneity and conformity compared with linear accelerator plans. ViewRay offers both adaptive radiotherapy and image guidance. The combination of cobalt-60 (Co-60) with 0.

View Article and Find Full Text PDF

Chondrosarcomas are relatively radiotherapy resistant, and also delivering high radiation doses is not feasible owing to anatomic constraints. In this study, the feasibility of helical tomotherapy for treatment of chondrosarcoma of thoracic spine is explored and compared with other available photon and proton radiotherapy techniques in the clinical setting. A patient was treated for high-grade chondrosarcoma of the thoracic spine using tomotherapy.

View Article and Find Full Text PDF

Background: We have analyzed the stability of CT to density curve of kilovoltage cone-beam computerized tomography (kV CBCT) imaging modality over the period of six months. We also, investigated the viability of using image value to density table (IVDT) generated at different time, for adaptive radiotherapy treatment planning. The consequences of target volume change and the efficacy of kV CBCT for adaptive planning issues is investigated.

View Article and Find Full Text PDF

This study highlights the use of adaptive planning to accommodate testicular shielding in helical tomotherapy for malignancies of the proximal thigh. Two cases of young men with large soft tissue sarcomas of the proximal thigh are presented. After multidisciplinary evaluation, preoperative radiation therapy was recommended.

View Article and Find Full Text PDF

Background And Purpose: To compare left-sided whole breast conventional and intensity-modulated radiotherapy (IMRT) treatment planning techniques.

Materials And Methods: Treatment plans were created for 10 consecutive patients. Three-dimensional conformal radiotherapy (3DCRT), forward-planned IMRT (for-IMRT), and inverse-planned IMRT (inv-IMRT) used two tangent beams.

View Article and Find Full Text PDF

Use of helical TomoTherapy-based MVCT imaging for adaptive planning is becoming increasingly popular. Treatment planning and dose calculations based on MVCT require an image value to electron density calibration to remain stable over the course of treatment time. In this work, we have studied the dosimetric impact on TomoTherapy treatment plans due to variation in image value to density table (IVDT) curve as a function of target degradation.

View Article and Find Full Text PDF

Purpose: To assess patient setup corrections based on daily megavoltage CT (MVCT) imaging for four anatomic treatment sites treated on tomotherapy.

Method And Materials: Translational and rotational setup corrections, based on registration of daily MVCT to planning CT images, were analyzed for 1,179 brain and head and neck (H&N), 1,414 lung, and 1,274 prostate treatment fractions. Frequencies of three-dimensional vector lengths, overall distributions of setup corrections, and patient-specific distributions of random and systematic setup errors were analyzed.

View Article and Find Full Text PDF

Recent initiatives of the American Board of Medical Specialties (ABMS) in the area of maintenance of certification (MOC) have been reflective of the response of the medical community to address public concerns regarding quality of care, medical error reduction, and patient safety. In March 2000, the 24 member boards of the ABMS representing all medical subspecialties in the USA agreed to initiate specialty-specific maintenance of certification (MOC) programs. The American Board of Radiology (ABR) MOC program for diagnostic radiology, radiation oncology, and radiologic physics has been developed, approved by the ABMS, and initiated with full implementation for all three disciplines beginning in 2007.

View Article and Find Full Text PDF

In image-guided radiation therapy, megavoltage computerized tomography (MVCT) delivers higher dose to the patient for lower image quality than diagnostic kilovoltage CT (kVCT). One way to reduce the mean imaging dose is to reduce the imaging volume, which is often sufficient for registration and dosimetry purposes. The filtered back projection using truncated data causes artefacts that degrade the image quality.

View Article and Find Full Text PDF

Maintenance of Certification (MOC) recognizes that in addition to medical knowledge, several essential elements involved in delivering quality care must be developed and maintained throughout one's career. The MOC process is designed to facilitate and document the professional development of each diplomate of The American Board of Radiology (ABR) through its focus on the essential elements of quality care in Diagnostic Radiology and its subspecialties, and in the specialties of Radiation Oncology and Radiologic Physics. The initial elements of the ABR-MOC have been developed in accord with guidelines of The American Board of Medical Specialties.

View Article and Find Full Text PDF

Deformable image registration is an important tool for image-guided radiotherapy. Physics-model-based deformable image registration using finite element analysis is one of the methods currently being investigated. The calculation accuracy of finite element analysis is dependent on given boundary conditions, which are usually based on the surface matching of the organ in two images.

View Article and Find Full Text PDF

In this paper we report on the testing and verification of a system for IMRT delivery quality assurance that uses a cylindrical solid water phantom with a spiral trajectory for radiographic film placement. This spiral film technique provides more complete dosimetric verification of the entire IMRT treatment than perpendicular film methods, since it samples a three-dimensional dose subspace rather than using measurements at only one or two depths. As an example, the complete analysis of the predicted and measured spiral films is described for an intracranial IMRT treatment case.

View Article and Find Full Text PDF

The purpose of this report is to evaluate the geometric movement (relative to the bony pelvis) and dose variation of brachytherapy reference points in the same patient at repeated high-dose rate (HDR) intracavitary implants. A study was also concluded to find the variation in treatment volume from repeated fractions. Twenty-five consecutive cervical cancer patients (all stages) treated with external beam and fractionated HDR intracavitary implants at the University of Wisconsin were reviewed.

View Article and Find Full Text PDF

A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_sessionc070mfvb3k99q59s40nisu15k7q692h1): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once