Publications by authors named "Beyna T"

Introduction: The performance of a high quality esophagogastroduodenoscopy (EGD) is dependent on the mucosal cleanliness. Recently, the Polprep: Effective Assessment of Cleanliness in EGD (PEACE) scale was created to assess the degree of mucosal cleanliness during EGD. The aim of this study was to validate this scoring system in a cohort of international endoscopists.

View Article and Find Full Text PDF

Introduction: The performance of a high quality esophagogastroduodenoscopy (EGD) is dependent on the mucosal cleanliness. Recently, the Polprep: Effective Assessment of Cleanliness in EGD (PEACE) scale was created to assess the degree of mucosal cleanliness during EGD. The aim of this study was to validate this scoring system in a cohort of international endoscopists.

View Article and Find Full Text PDF

1: ESGE recommends the combination of endoscopic ultrasound-guided tissue acquisition (EUS-TA) and endoscopic retrograde cholangiopancreatography (ERCP)-based tissue acquisition as the preferred diagnostic approach for tissue acquisition in patients with jaundice and distal extrahepatic biliary stricture in the absence of a pancreatic mass. 2: ESGE suggests that brushing cytology should be completed along with fluoroscopy-guided biopsies, wherever technically feasible, in patients with perihilar biliary strictures. 3: ESGE suggests EUS-TA for perihilar strictures when ERCP-based modalities yield insufficient results, provided that curative resection is not feasible and/or when cross-sectional imaging has shown accessible extraluminal disease.

View Article and Find Full Text PDF
Article Synopsis
  • This study evaluated the use of motorized spiral enteroscopy (MSE) for performing biliary endoscopic retrograde cholangiopancreatography (ERCP) in patients with altered surgical anatomy at five centers in Europe.
  • Out of 89 enrolled patients, MSE-assisted ERCP had a technical success rate of 54%, while adverse events occurred in 14% of cases, including one serious incident of esophageal perforation.
  • The study was halted in July 2023 due to safety concerns after the MSE device was withdrawn by the manufacturer, indicating potential risks associated with the procedure.
View Article and Find Full Text PDF

The following case describes the relapsing and ultimately fatal outcome of DRESS (drug reaction with eosinophilia and systemic symptoms) syndrome as an often misdiagnosed drug-induced hypersensitivity reaction. The disease was complicated by progressive worsening with involvement of multiple organs and profound agranulocytosis. The main goal of this article is to raise awareness of the syndrome and its potential severity.

View Article and Find Full Text PDF

Careful patient selection is a key factor in optimizing the use of device-assisted enteroscopy (DAE) in Crohn's disease (CD). Current technologies include double-balloon enteroscopy and single-balloon enteroscopy which have similar efficiency and safety. DAE allows a variety of therapeutic interventions in the small bowel (SB).

View Article and Find Full Text PDF

Purpose: The necessity of routine drain placement in pancreatic resections is controversial. Some randomized controlled trials have shown that the omission of drainage is safe for some patients, whereas reintervention rates and mortality rates are substantial for others. The present study aimed to assess fistula-associated outcomes in the setting of routine drain placement and drain irrigation on demand.

View Article and Find Full Text PDF

Percutaneous transhepatic cholangioscopy (PTCS) is a management option for patients in whom peroral cholangioscopy or endoscopic retrograde cholangiopancreatography (ERCP) fail. We conducted a case series on the efficacy and safety of PTCS using a cholangiopancreatoscope cleared by the US Food and Drug Administration in 2020. Fifty adult patients scheduled for PTCS or other cholangioscopic procedure were enrolled at seven academic medical centers and followed for 30 days after the index procedure.

View Article and Find Full Text PDF

Background:  Piecemeal endoscopic mucosal resection (EMR) is an acceptable technique for T1a esophageal adenocarcinoma, but en bloc R0 excision is advocated for T1b disease as it may offer a potential cure and mitigate recurrence. Thus, distinguishing between T1a and T1b disease is imperative under current treatment paradigms. We investigated whether expert Barrett's endoscopists could make this distinction based on optical evaluation.

View Article and Find Full Text PDF

Introduction: Long-term outcome data are limited for non-achalasia esophageal motility disorders treated by peroral endoscopy myotomy (POEM) as a separate group. We investigated a subset of symptomatic patients with hypercontractile esophagus (Jackhammer esophagus).

Methods: Forty two patients (mean age 60.

View Article and Find Full Text PDF

Background: Early Barrett cancer can be curatively treated by endoscopic resection. The choice of the resection technique, however-endoscopic mucosal resection (EMR) or submucosal dissection (ESD)-largely depends on the assumed infiltration depth as judged by the endoscopist. However, the accuracy of endoscopic diagnosis of the degree of cancer infiltration is not known.

View Article and Find Full Text PDF

Background And Aims: Characterization of visible abnormalities in patients with Barrett's esophagus (BE) can be challenging, especially for inexperienced endoscopists. This results in suboptimal diagnostic accuracy and poor interobserver agreement. Computer-aided diagnosis (CADx) systems may assist endoscopists.

View Article and Find Full Text PDF

Background: Nowadays, large benign lateral spreading lesions (LSLs) and sessile polyps in the colorectum are mostly resected by endoscopic mucosal resection (EMR). A major drawback of EMR is the polyp recurrence rate of up to 20%. Snare tip soft coagulation (STSC) is considered an effective technique to reduce recurrence rates.

View Article and Find Full Text PDF

Background: Computer-aided detection (CADe) systems could assist endoscopists in detecting early neoplasia in Barrett's oesophagus, which could be difficult to detect in endoscopic images. The aim of this study was to develop, test, and benchmark a CADe system for early neoplasia in Barrett's oesophagus.

Methods: The CADe system was first pretrained with ImageNet followed by domain-specific pretraining with GastroNet.

View Article and Find Full Text PDF

Ampullary neoplastic lesions (ANLs) represent a rare cancer, accounting for about 0.6-0.8% of all gastrointestinal malignancies, and about 6-17% of periampullary tumors.

View Article and Find Full Text PDF

Chronic pancreatitis (CP) is an ongoing inflammatory disease with most patients developing pancreatic calculi during their course of disease. Extracorporeal shock wave lithotripsy (ESWL) is a first-line treatment option in patients with large lumen obstructing pancreatic duct (PD) stones. In patients with CP and PD dilatation, digital single-operator pancreatoscopy (DSOP)-guided lithotripsy seems to be an appealing option to ESWL and surgery.

View Article and Find Full Text PDF
Article Synopsis
  • The first single-use duodenoscope was approved for use in the US in December 2019, and doctors needed more information on how well it worked in different situations.
  • A study involved 61 doctors from 22 hospitals in 11 countries who performed a procedure called ERCP on adult patients, checking how many were successful and if there were any problems.
  • Out of 551 patients treated, most (96%) had successful procedures using the single-use duodenoscope, with doctors expressing high satisfaction with its performance, despite some patients experiencing complications.
View Article and Find Full Text PDF

Introduction: Endoscopic vacuum therapy (EVT) has emerged as a promising treatment option for upper gastrointestinal wall defects, offering benefits such as evacuation of secretions and removal of wound debris by suction, and reduction and healing of wound cavities to improve clinical outcomes. In contrast, covered stents have a high rate of migration and lack functional drainage, while endoluminal EVT devices obstruct the GI tract. The VACStent is a novel device that combines the benefits of EVT and stent placement.

View Article and Find Full Text PDF

Introduction: Endoscopic detection of early neoplasia in Barrett's esophagus is difficult. Computer Aided Detection (CADe) systems may assist in neoplasia detection. The aim of this study was to report the first steps in the development of a CADe system for Barrett's neoplasia and to evaluate its performance when compared with endoscopists.

View Article and Find Full Text PDF

Background And Aims: The introduction of motorized spiral enteroscopy (mSE) into clinical practice holds diagnostic and therapeutic potential for small-bowel investigations. This systematic review and meta-analysis aims to evaluate the performance of this modality in diagnosing and treating small-bowel lesions.

Methods: A systematic search of MEDLINE, Cochrane, and ClinicalTrials.

View Article and Find Full Text PDF

Background: Endoscopic ultrasound-guided biliary drainage (EUS-BD) was associated with better clinical success and a lower rate of adverse events (AEs) than fluoroscopy-guided percutaneous transhepatic biliary drainage (PTBD) in recent single center studies with mainly retrospective design and small case numbers (< 50). The aim of this prospective European multicenter study is to compare both drainage procedures using ultrasound-guidance and primary metal stent implantation in patients with malignant distal bile duct obstruction (PUMa Trial).

Methods: The study is designed as a non-randomized, controlled, parallel group, non-inferiority trial.

View Article and Find Full Text PDF

Background And Aims: Endoscopic retrograde cholangiopancreatography (ERCP), in surgically altered anatomy (SAA), can be challenging and the optimal technique selection remains debatable. Most common foregut interventions resulting to this burden consist of Billroth II gastrectomy, Whipple surgery and Roux-en-Y anastomoses, including gastric by-pass. This systematic review, with meta-analysis, aimed to compare the rates of successful enteroscope-assisted (EA)-, endosonography-directed transgastric- (EDGE), and laparoscopy-assisted (LA)-ERCP.

View Article and Find Full Text PDF

BACKGROUND : Motorized spiral enteroscopy (MSE) was recently introduced into clinical practice. The aim of the current study was to evaluate the feasibility and safety of MSE for biliopancreatic interventions in patients with surgically altered anatomy. METHODS : Patients with surgically altered anatomy receiving MSE-assisted ERCP at a single, endoscopy referral center were retrospectively enrolled between January 2016 and June 2021.

View Article and Find Full Text PDF