Publications by authors named "Betts T"

Article Synopsis
  • Inappropriate therapy (IAT) is a significant issue associated with implantable cardiac defibrillator (ICD) therapy, particularly highlighted in early subcutaneous ICD (S-ICD) studies which showed high rates of inappropriate shocks (IAS).
  • The PRAETORIAN trial, an international study with 849 patients, found no major differences in IAT and IAS rates between S-ICD and transvenous ICD (TV-ICD) groups, as both groups had similar cumulative incidences.
  • Key predictors for IAT varied between the two groups, with TV-ICD patients experiencing IAT mainly from supraventricular tachycardias, while S-ICD patients faced issues from cardiac oversensing
View Article and Find Full Text PDF
Article Synopsis
  • The S-ICD was created to eliminate lead-related issues found in the TV-ICD, as it is an external device that sits under the skin rather than using leads inside the body.
  • This analysis comes from the PRAETORIAN trial, where patients were randomly assigned to either S-ICD or TV-ICD and assessed for quality of life through various questionnaires at different stages.
  • Results showed no significant differences in physical and mental well-being between the groups, but patients who experienced a shock recently reported lower social functioning and emotional health compared to those who did not.
View Article and Find Full Text PDF

Frailty is common among older patients with heart failure (HF). The efficacy of coronary artery bypass grafting (CABG) on the risk of mortality among frail patients with ischemic cardiomyopathy and HF is uncertain, and whether frailty burden modifies the treatment benefits of CABG among these patients is unknown. We performed a post hoc analysis of the STICHES trial, a randomized trial of CABG with medical therapy vs medical therapy alone among participants with ischemic cardiomyopathy with ejection fraction ≤ 35%.

View Article and Find Full Text PDF

Introduction: The novel Confirm Rx™ implantable cardiac monitor (ICM) with SharpSense™ technology incorporates a new P-wave discriminator designed to improve AF detection. This study aimed to evaluate the diagnostic performance of the Confirm Rx™ ICM in detecting AF episodes of varying durations.

Methods: We conducted a multicenter retrospective analysis of consecutive patients implanted with a Confirm Rx™ ICM (v1.

View Article and Find Full Text PDF

Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia associated with significant morbidity and mortality. Managing risk of stroke and AF burden are pillars of AF management. Atrial geometry has long been recognized as a useful measure in achieving these goals.

View Article and Find Full Text PDF

Background: When using lesion size index (LSI) to guide catheter ablation, it is unclear what combination of power, contact force and time would be preferable to use and what LSI target value to aim for. This study aimed at identifying desirable ablation settings and LSI targets by using tissue impedance drop as indicator of lesion formation.

Methods: Consecutive patients, undergoing their first left atrial (LA) catheter ablation for atrial fibrillation, with radiofrequency energy (RF) powers of 20, 30 and 40 W were enrolled.

View Article and Find Full Text PDF
Article Synopsis
  • About 40% of heart failure patients eligible for cardiac resynchronization therapy (CRT) do not respond or cannot be treated, highlighting the need for alternative options.
  • The SOLVE-CRT study evaluated the safety and effectiveness of a new leadless left ventricular pacing system for high-risk patients or those who had unsuccessful CRT using conventional methods.
  • The study involved 183 participants, primarily older males, and was stopped early due to positive results showing improvements in safety and a decrease in heart chamber size.
View Article and Find Full Text PDF
Article Synopsis
  • - Study aimed to determine factors influencing early mortality after left atrial appendage occlusion (LAAO) to improve patient selection and cost-effectiveness for stroke prevention.
  • - Analyzed data from 1,020 patients, finding a 2-year mortality rate of 16.4%, with 50% of deaths attributed to non-cardiovascular causes, and identified six key predictors of mortality including age and heart failure.
  • - Concluded that as the number of risk factors in patients increased, the mortality rate rose significantly, underscoring the need for careful patient selection for LAAO procedures.
View Article and Find Full Text PDF

Two rehydration protocols currently exist to treat diabetic ketoacidosis (DKA) in pediatric patients aged <21 years: the traditional "one-bag" system and the more recent "two-bag" system. This study aimed to evaluate the safety and efficacy of the newer two-bag system versus the well-established one-bag system. The CiNAHL, Cochrane Library, Embase, PubMed, Scopus, and Web of Science databases were comprehensively searched from inception to June 2023 by 2 independent reviewers using the Preferred Reporting Items for Systematic Reviews and Meta-analysis framework.

View Article and Find Full Text PDF

During the COVID-19 pandemic, the introduction of non-pharmaceutical interventions (NPIs) resulted in an unprecedented reduction in the transmission of the respiratory syncytial virus (RSV), the predominant cause of bronchiolitis. As NPIs were eased, it was speculated that RSV transmission would return with an increase in the severity of bronchiolitis. In a large tertiary hospital, a dramatic reduction in the incidence of bronchiolitis was seen during the COVID-19 pandemic.

View Article and Find Full Text PDF

Aims: Patients with persistent atrial fibrillation (AF) experience 50% recurrence despite pulmonary vein isolation (PVI), and no consensus is established for secondary treatments. The aim of our i-STRATIFICATION study is to provide evidence for stratifying patients with AF recurrence after PVI to optimal pharmacological and ablation therapies, through in silico trials.

Methods And Results: A cohort of 800 virtual patients, with variability in atrial anatomy, electrophysiology, and tissue structure (low-voltage areas, LVAs), was developed and validated against clinical data from ionic currents to electrocardiogram.

View Article and Find Full Text PDF

Aims: The trials upon which recommendations for the use of cardiac resynchronization therapy (CRT) in heart failure used optimal medical therapy (OMT) before sodium-glucose co-transporter 2 inhibitors (SGLT2i). Moreover, the SGLT2i heart failure trials included only a small proportion of participants with CRT, and therefore, it remains uncertain whether SGLT2i should be considered part of OMT prior to CRT.

Methods And Results: We compared electrocardiogram (ECG) and echocardiographic responses to CRT as well as hospitalization and mortality rates in consecutive patients undergoing implantation at a large tertiary centre between January 2019 to June 2022 with and without SGLT2i treatment.

View Article and Find Full Text PDF

Percutaneous left atrial appendage occlusion aims to reduce the risk of stroke in patients with AF, particularly those who are not good candidates for systemic anticoagulation. The procedure has been studied in large international randomised trials and registries and was approved by the National Institute for Health and Care Excellence in 2014 and by NHS England in 2018. This position statement summarises the evidence for left atrial appendage occlusion and presents the current indications.

View Article and Find Full Text PDF

Percutaneous left atrial appendage occlusion aims to reduce the risk of stroke in patients with AF, particularly those who are not good candidates for systemic anticoagulation. The procedure has been studied in large international randomised trials and registries and was approved by the National Institute for Health and Care Excellence in 2014 and by NHS England in 2018. This position statement summarises the evidence for left atrial appendage occlusion and presents the current indications.

View Article and Find Full Text PDF

Background: The PRAETORIAN score estimates the risk of failure of subcutaneous implantable cardioverter-defibrillator (S-ICD) therapy by using generator and lead positioning on bidirectional chest radiographs. The PRospective randomized compArative trial of subcutanEous implanTable cardiOverter-defibrillatoR ImplANtation with and without DeFibrillation Testing (PRAETORIAN-DFT) investigates whether PRAETORIAN score calculation is noninferior to defibrillation testing (DFT) with regard to first shock efficacy in spontaneous events.

Objective: This prespecified subanalysis assessed the predictive value of the PRAETORIAN score for defibrillation success in induced ventricular arrhythmias.

View Article and Find Full Text PDF

Encapsulation is a well-known impact factor on the durability of Photovoltaics (PV) modules. Currently there is a lack of understanding on the relationship between lamination process and module durability. In this paper, the effects of different lamination parameters on the encapsulant stability due to stress testing have been investigated from both on-site production quality and long-term stability viewpoints.

View Article and Find Full Text PDF

Introduction: Fusion pacing requires correct timing of left ventricular pacing to right ventricular activation, although it is unclear whether this is maintained when atrioventricular (AV) conduction changes during exercise. We used cardiopulmonary exercise testing (CPET) to compare cardiac resynchronization therapy (CRT) using fusion pacing or fixed AV delays (AVD).

Methods: Patients 6 months post-CRT implant with PR intervals < 250 ms performed two CPET tests, using either the SyncAV™ algorithm or fixed AVD of 120 ms in a double-blinded, randomized, crossover study.

View Article and Find Full Text PDF

The first edition of Europace journal in 1999 came right around the time of the landmark publication of the electrophysiologists from Bordeaux, establishing how elimination of ectopic activity from the pulmonary veins (PVs) resulted in a marked reduction of atrial fibrillation (AF). The past 25 years have seen an incredible surge in scientific interest to develop new catheters and energy sources to optimize durability and safety of ablation, as well as study the mechanisms for AF and devise ablation strategies. While ablation in the beginning was performed with classic 4 mm tip catheters that emitted radiofrequency (RF) energy to create tissue lesions, this evolved to using irrigation and contact force (CF) measurement while increasing power.

View Article and Find Full Text PDF

Aims: In patients with a low AF burden and long periods of sinus rhythm, 'pill-in-the-pocket' oral anticoagulation (OAC) may, taken as needed in response to AF episodes, offer the same thromboembolic protection as continuous, life-long OAC, while reducing bleeding complications at the same time. The purpose of this study is to systematically summarise available evidence pertaining to the feasibility, safety and efficacy of pill-in-the-pocket OAC.

Methods: Medline and Embase were searched from inception to July 2022 for studies adopting a pill-in-the-pocket OAC strategy in AF patients guided by daily rhythm monitoring (PROSPERO/CRD42020209564).

View Article and Find Full Text PDF

Background: Implantable cardioverter-defibrillator (ICD) therapy is recommended to reduce mortality risk in patients with heart failure with reduced ejection fraction (HFrEF). Frailty is common among patients with HFrEF and is associated with increased mortality risk. Whether the therapeutic efficacy of ICD is consistent among frail and nonfrail patients with HFrEF remains unclear.

View Article and Find Full Text PDF

Background: Transjugular liver biopsy (TJLB) procedurally samples liver tissue through the internal jugular vein. It is indicated in the presence of coagulopathies and/or ascites.

Aims: This meta-analysis aimed to assess the safety and efficacy of TJLB in children.

View Article and Find Full Text PDF

The best pharmacological treatment for each atrial fibrillation (AF) patient is unclear. We aim to exploit AF simulations in 800 virtual atria to identify key patient characteristics that guide the optimal selection of anti-arrhythmic drugs. The virtual cohort considered variability in electrophysiology and low voltage areas (LVA) and was developed and validated against experimental and clinical data from ionic currents to ECG.

View Article and Find Full Text PDF

Aims: Electro-anatomical mapping may be critical to identify atrial fibrillation (AF) subjects who require substrate modification beyond pulmonary vein isolation (PVI). The objective was to determine correlations between pre-ablation mapping characteristics and 12-month outcomes after a single PVI-only catheter ablation of AF.

Methods And Results: This study enrolled paroxysmal AF (PAF), early persistent AF (PsAF; 7 days-3 months), and non-early PsAF (>3-12 months) subjects undergoing de novo PVI-only radiofrequency catheter ablation.

View Article and Find Full Text PDF

Aims: RECOVER AF evaluated the performance of whole-chamber non-contact charge-density mapping to guide the ablation of non-pulmonary vein (PV) targets in persistent atrial fibrillation (AF) patients following either a first or second failed procedure.

Methods And Results: RECOVER AF was a prospective, non-randomized trial that enrolled patients scheduled for a first or second ablation retreatment for recurrent AF. The PVs were assessed and re-isolated if necessary.

View Article and Find Full Text PDF

While sudden cardiac death (SCD) in hypertrophic cardiomyopathy (HCM) is due to arrhythmias, the guidelines for prediction of SCD are based solely on non-electrophysiological methods. This study aims to stimulate thinking about whether the interests of patients with HCM are better served by using current, 'risk factor', methods of prediction or by further development of electrophysiological methods to determine arrhythmic risk. Five published predictive studies of SCD in HCM, which contain sufficient data to permit analysis, were analysed to compute receiver operating characteristics together with their confidence bounds to compare their formal prediction either by bootstrapping or Monte Carlo analysis.

View Article and Find Full Text PDF