A new x-ray imaging crystal spectrometer (XICS) has been installed, aligned, and used during experimental campaigns on the WEST tokamak. It has three interchangeable crystals for measuring the Ar XVII, Ar XVIII, and Fe XXV spectra, respectively. A patented rotating table holding the crystals is used to monitor the crystal facing the plasma remotely and without changing the position of the camera.
View Article and Find Full Text PDFRev Sci Instrum
November 2016
In the present and the next generation of fusion devices, imaging Bragg spectrometers are key diagnostics to measure plasma parameters in the hot core, especially ion temperature and plasma rotation. The latter quantities are routinely obtained using the Doppler-width and -shift of the emitted spectral lines, respectively. Line shift measurements require absolute accuracies Δλ/λ of about 10 ppm, where λ-is the observed wavelength.
View Article and Find Full Text PDFRev Sci Instrum
October 2008
The quantitative exploitation of active beam spectra is largely based on an advanced atomic modeling. Under the ITER operating conditions the penetration depth of a diagnostic beam into the plasma core crucially affects the intensities of spectral lines and hence the uncertainties of derived plasma parameters. A critical review of atomic data and an assessment of its error margins are, therefore, urgently needed.
View Article and Find Full Text PDFDichroic filters have been used to shield effectively the far infrared (FIR) detectors at the interferometer/polarimeter on TEXTOR. The filters consist of metal foils with regular holes, the hole diameter, the mutual spacing and the thickness of the foils are chosen to transmit radiation at the design frequency with transmission >90%. The attenuation at the low frequency end of the bandpass filter is about 30 dB per octave, the high frequency transmission is between 20% and 40%.
View Article and Find Full Text PDFA significant influence of the dynamic ergodic divertor (DED) on the density limit in TEXTOR has been found. In Ohmic discharges, where without DED detachment normally arises at the density limit, a MARFE (multifaceted asymmetric radiation from the edge) develops when the DED is operated in a static regime. The threshold of the MARFE onset in the neutral beam heated plasmas is increased by applying 1 kHz ac DED at the high-field side.
View Article and Find Full Text PDFThe first results of the Dynamic Ergodic Divertor in TEXTOR, when operating in the m/n=3/1 mode configuration, are presented. The deeply penetrating external magnetic field perturbation of this configuration increases the toroidal plasma rotation. Staying below the excitation threshold for the m/n=2/1 tearing mode, this toroidal rotation is always in the direction of the plasma current, even if the toroidal projection of the rotating magnetic field perturbation is in the opposite direction.
View Article and Find Full Text PDFDielectronic satellite spectra of heliumlike argon, recorded with a high-resolution x-ray crystal spectrometer at the National Spherical Torus Experiment, were found to be inconsistent with existing predictions resulting in unacceptable values for the power balance and suggesting the unlikely existence of non-Maxwellian electron energy distributions. These problems were resolved with calculations from a new atomic code. It is now possible to perform reliable electron-temperature measurements and to eliminate the uncertainties associated with determinations of non-Maxwellian distributions.
View Article and Find Full Text PDF