Objective: With an ageing population and a rising number of people with chronic conditions and disabilities, pressure ulcers (PUs) are a frequent problem. Prevention and treatment, especially targeted at older people, frail and non-self-sufficient patients, are central to care provided by nurses. The objective of this study is to establish the incidence of PUs in hospital inpatients and identify possible associated risk factors.
View Article and Find Full Text PDFAims: To assess the effects of bed rest duration on short-term complications following transfemoral catheterization.
Methods And Results: A systematic search was carried out in MEDLINE, Embase, CINAHL, Cochrane Database of Systematic Reviews, Scopus, SciELO and in five registries of grey literature. Randomized controlled trials and quasi-experimental studies comparing different durations of bed rest after transfemoral catheterization were included.
Background: Transfemoral cardiac catheterisation is an invasive medical procedure used for therapeutic or diagnostic purposes. Postoperative bed rest can prevent a number of complications such as bleeding and haematoma formation and can result in side effects such as back pain and urinary discomfort. Currently, there is no consensus regarding the optimal length of bed rest.
View Article and Find Full Text PDFCar lubricant additives are added to mineral or synthetic base stocks to improve viscosity and resistance to oxidation of the lubricant and to limit wear of engines. In previous papers related to this purpose, it was demonstrated that SFC allows the elution of common low molecular weight additives. Since their total resolution could not be achieved owing to the limited peak capacity of packed columns, the hyphenation of selective and informative detectors, atomic emission and mass spectrometry, were also carried out for identification.
View Article and Find Full Text PDFA new multidimensional chromatographic instrument has been developed to perform both SFC-GC×GC and SFC×GC×GC, in response to the challenge of complex matrices characterization. The design of this online system is fully described and enriched by theoretical and practical discussions. A new interface has been investigated: this interface allows the temporary storage of SFC fractions inside sampling loops before their quantitative transfer toward the GC×GC.
View Article and Find Full Text PDFIn the Alectoris partridges (Phasianidae), hybridization occurs occasionally as a result of the natural breakdown of isolating mechanisms but more frequently as a result of human activity. No genetic record of hybridization is known for the barbary partridge (A. barbara).
View Article and Find Full Text PDFExtending the knowledge on sulfur-containing compounds is crucial for the petroleum industry because they contribute to atmospheric pollution by combustion. Most of them are concentrated in heavy petroleum cuts, such as vacuum gas oils (VGOs). However, the resolution of the existing analytical methods does not allow a quantitative speciation of S-compounds contained in VGOs.
View Article and Find Full Text PDFExtending the knowledge related to nitrogen-containing compounds presents an important interest for the petroleum industry due to their implication in atmosphere pollution as well as their inhibitive or refractive behaviour towards hydroprocessing. Most of the nitrogenated species are concentrated in heavy petroleum cuts. As no analytical method is resolutive enough for these heavy cuts, particularly regarding nitrogen-containing compounds, a new approach is needed.
View Article and Find Full Text PDFIn a context of environmental preservation, purification and conversion of heavy petroleum cuts into high-quality fuel becomes essential. The interest for the characterization of those very complex matrices becomes a trendy analytical challenge, when it comes to get molecular information for the optimization of industrial processes. Among new analytical techniques, high-temperature 2-D GC has recently proved its applicability to heavy petroleum matrices, but lacks in selectivity to separate all chemical groups.
View Article and Find Full Text PDFThis paper reports the conditions of online hyphenation of supercritical fluid chromatography (SFC) with twin comprehensive two-dimensional gas chromatography (twin-GCxGC) for detailed characterization of middle distillates; this is essential for a better understanding of reactions involved in refining processes. In this configuration, saturated and unsaturated compounds that have been fractionated by SFC are transferred on two different GC x GC columns sets (twin-GCxGC) placed in the same GC oven. Cryogenic focusing is used for transfer of fractions into the first dimension columns before simultaneous GCxGC analysis of both saturated and unsaturated fractions.
View Article and Find Full Text PDFIn a tense energetic context, the characterization of heavy petroleum fractions becomes essential. Conventional comprehensive two-dimensional gas chromatography (2D-GC or GCxGC) is widely used for middle distillates analysis, but only a few applications are devoted to these heavier fractions. In this paper, it is shown how the optimization of GCxGC separation allowed the determination of suitable high-temperature (HT) conditions, adjusting column properties and operating conditions.
View Article and Find Full Text PDFIn the current energetic context (increasing consumption of vehicle fuels, greenhouse gas emission etc.) government policies lead to mandatory introduction in fossil fuels of fuels resulting from renewable sources of energy such as biomass. Blending of fatty acid alkyl esters from vegetable oils (also known as biodiesel) with conventional diesel fuel is one of the solutions technologically available; B5 blends (up to 5%w/w esters in fossil fuel) are marketed over Europe.
View Article and Find Full Text PDFA new column association using comprehensive two-dimensional gas chromatography for the detailed molecular analysis of hydrocarbon mixtures is reported in this paper. In order to compare the impact of two different secondary columns, a novel column combination relying on a GC x 2GC system was used. This system is based on a non-polar first column (PONA) combined with both a permethylated beta-cyclodextrin (beta-Dex 120) stationary phase and a polysilphenylensiloxane (BPX 50) in the second dimension.
View Article and Find Full Text PDFThe detailed characterization of middle distillates is essential for a better understanding of reactions involved in refining processes. Owing to a higher resolution power and an enhanced sensitivity, but especially to a group-type ordering in the chromatographic plane, comprehensive two-dimensional gas chromatography (GCxGC) offers unsurpassed characterization possibilities for petroleum samples. However, GCxGC fails to totally discriminate naphthenes from unsaturates occurring in hydrotreated diesel samples.
View Article and Find Full Text PDFCar lubricant additives are added to mineral or synthetic base stocks to improve viscosity and resistance to oxidation of the lubricant and to limit wear of engines. Their total amount in the commercial lubricant varies from a few percents to 20-25%. As they belong to various chemical classes and are added to a very complex medium, the base stock, their detailed chromatographic analysis is very difficult and time consuming as it should involve sample treatment and preparative scale separations in order to simplify the sample.
View Article and Find Full Text PDFThis paper reports an analytical method for the comprehensive two-dimensional gas chromatography (GC x GC) separation and identification of nitrogen compounds (N-compounds) in middle distillates according to their types (basicity). For the evaluation of the best chromatographic conditions, a non-polar x polar approach was chosen. The impact of the second dimension (stationary phase and column length) on the separation of basic and neutral N-compounds was evaluated by mean of two-dimensional resolution.
View Article and Find Full Text PDFThe monitoring of total sulfur content and speciation of individual sulfur-containing compounds in middle distillates is required for efficient catalyst selection and for a better understanding of the kinetics of the reactions involved in hydrotreament processes. Owing to higher resolution power and enhanced sensitivity, comprehensive two-dimensional gas chromatography (GCxGC) hyphenated to sulfur chemiluminescence detection (SCD) has recently evolved as a powerful tool for improving characterization and identification of sulfur compounds. The aim of this paper is to compare quantitatively GCxGC-SCD and various other methods commonly employed in the petroleum industry, such as X-ray fluorescence, conventional GC-SCD, and high-resolution mass spectrometry, for total sulfur content determination and speciation analysis.
View Article and Find Full Text PDFIn contaminated soils, efficiency of natural attenuation or engineered bioremediation largely depends on biodegradation capacities of the local microflorae. In the present study, the biodegradation capacities of various microflorae towards diesel oil were determined in laboratory conditions. Microflorae were collected from 9 contaminated and 10 uncontaminated soil samples and were compared to urban wastewater activated sludge.
View Article and Find Full Text PDFA multidimensional method providing the composition of a heavy naphtha in paraffins, isoparaffins, olefins, naphthenes, and aromatics (PIONA) in the C8-C14 range is presented. The analytical set-up consists in a silver modified silica olefin trap on-line coupled to comprehensive two-dimensional gas chromatography (GC x GC). In this configuration, hydrocarbons are separated, in gaseous state, in two fractions, saturate and unsaturate, each fraction being subsequently analysed by GC or by GC x GC.
View Article and Find Full Text PDFThe detailed characterisation of middle distillates is essential for a better understanding of reactions involved in refining process. Owing to higher resolution power and enhanced sensitivity, comprehensive two-dimensional gas chromatography (GC x GC) is a powerful tool for improving characterisation of petroleum samples. The aim of this paper is to compare GC x GC and various ASTM methods -- gas chromatography (GC), liquid chromatography (LC) and mass spectrometry (MS) -- for group type separation and detailed hydrocarbon analysis.
View Article and Find Full Text PDFModeling the retention in comprehensive two-dimensional gas chromatography (GC x GC) was achieved using retention indices obtained in conventional GC. Predicted results were compared with experimental data obtained in the two-dimensional separation of a synthetic hydrocarbon mixture. This proved to be helpful in optimizing the operating conditions of GC x GC separation of a complex petroleum sample and in identifying chemical families.
View Article and Find Full Text PDFComprehensive two-dimensional gas chromatography (GC x GC) has been investigated for the characterization of high valuable petrochemical samples from dehydrogenation of n-paraffins, Fischer-Tropsch and oligomerization processes. GC x GC separations, performed using a dual-jets CO2 modulator, were optimized using a test mixture representative of the hydrocarbons found in petrochemicals. For complex samples, a comparison of GC x GC qualitative and quantitative results with conventional gas chromatography (1D-GC) has demonstrated an improved resolution power of major importance for the processes: the group type separation has permitted the detection of aromatic compounds in the products from dehydrogenation of n-paraffins and from oligomerization, and the separation of alcohols from other hydrocarbons in Fischer-Tropsch products.
View Article and Find Full Text PDFInterfacing and evaluation of packed column supercritical fluid chromatography (SFC)-microwave-induced plasma atomic emission detection (AED) is described. Via a flow splitter and an integral restrictor, efficient transfer of solutes from column to detector without band broadening is obtained. Variation of CO2 flow-rate during pressure gradients has little influence on both AED signal and baseline drift while it provides similar sensitivity as in capillary SFC.
View Article and Find Full Text PDF