Background: Recent evidence suggests atrial fibrillation (AF) causes cardiomyopathy due to remodeling driven by both irregular rate and rhythm. Atrial fibrillation (AF) ablation in patients with reduced ejection fraction (EF) ≤ 35% has been shown to improve EF and mortality. It is unknown whether the benefits of AF ablation among patients with reduced EF are affected by the degree of pre-ablation rate control.
View Article and Find Full Text PDFBackground: Catheter ablation (CA) for ventricular tachycardia (VT) can be a useful treatment strategy, however, few studies have compared CA to medical therapy (MT) in the sarcoidosis population.
Objective: To assess in-hospital outcomes and unplanned readmissions following CA for VT compared to MT in patients with sarcoidosis.
Methods: Data was obtained from the Nationwide Readmissions Database between 2010 and 2019 to identify patients with sarcoidosis admitted for VT either undergoing CA or MT during elective and non-elective admission.
Background: Many patients with mildly to moderately reduced left ventricular ejection fraction (LVEF) who require permanent pacemaker (PPM) implantation do not have a concurrent indication for implantable cardioverter-defibrillator (ICD) therapy. However, the risk of ventricular tachycardia/ventricular fibrillation (VT/VF) in this population is unknown.
Objective: The aim of this study was to describe the risk of VT/VF after PPM implantation in patients with mildly to moderately reduced LVEF.
Objectives: We investigated characteristics of left atrial conduction in patients with HCM, paroxysmal AF and normal bipolar voltage.
Background: Patients with hypertrophic cardiomyopathy (HCM) exhibit abnormal cardiac tissue arrangement. The incidence of atrial fibrillation (AF) is increased fourfold in patients with HCM and confers a fourfold increased risk of death.
Background: Established electroanatomic mapping techniques for substrate mapping for ventricular tachycardia (VT) ablation includes voltage mapping, isochronal late activation mapping (ILAM), and fractionation mapping. Omnipolar mapping (Abbott Medical, Inc.) is a novel optimized bipolar electrogram creation technique with integrated local conduction velocity annotation.
View Article and Find Full Text PDFIntroduction: Radiofrequency ablation technology for treating atrial fibrillation (AF) has evolved rapidly over the past decade. We investigated the impact of technological and procedural advances on procedure times and ablation outcomes at a major academic medical center over a 10-year period.
Methods: Clinical data was collected from patients who presented to NYU Langone Health between 2011 and 2021 for a first-time AF ablation.
Introduction: Radiofrequency ablation (RFA) slow pathway modification for catheter ablation of atrioventricular nodal reentrant tachycardia (AVNRT) is traditionally performed using a 4-mm nonirrigated (NI) RF ablation catheter. Slow pathway modification using irrigated, contact-force sensing (ICFS) RFA catheters has been described in case reports, but the outcomes have not been systematically evaluated.
Methods: Acute procedural outcomes of 200 consecutive patients undergoing slow pathway modification for AVNRT were analyzed.
Introduction: Patients with HIV infection have increased risk of atrial fibrillation, but the pathophysiologic mechanisms and the utility of catheter ablation in this population are not well-studied. We aimed to characterize outcomes of atrial fibrillation ablation and left atrial substrate in patients with HIV.
Methods: The study was a retrospective propensity score-matched analysis of patients with and without HIV undergoing atrial fibrillation ablation.
Background: With the growing use of implantable cardiac devices, the need for transvenous lead extraction has increased, which translates to increased procedural volumes. Sex differences in lead extraction outcomes are not well studied.
Objective: The present study aims at evaluating the impact of sex on outcomes of lead extraction.
Objectives: In the context of the ongoing overdose crisis, a stark increase in toxic drug deaths from the unregulated street supply accompanied the onset of the COVID-19 pandemic. Injectable opioid agonist treatment (iOAT - hydromorphone or medical-grade heroin), tablet-based iOAT (TiOAT), and safer supply prescribing are emerging interventions used to address this crisis in Canada. Given rapid clinical guidance and policy change to enable their local adoption, our objectives were to describe the state of these interventions before the pandemic, and to document and explain changes in implementation during the early pandemic response (March-May 2020).
View Article and Find Full Text PDFBackground: Hypertrophic cardiomyopathy (HCM) is the most prevalent inherited cardiomyopathy. The implantable cardioverter-defibrillator (ICD) is important for prevention of sudden cardiac death (SCD) in patients at high risk. In recent years, the subcutaneous implantable cardioverter-defibrillator (S-ICD) has emerged as a viable alternative to the transvenous implantable cardioverter-defibrillator (TV-ICD).
View Article and Find Full Text PDFJ Cardiovasc Electrophysiol
February 2022
Introduction: Prior studies have shown that addition of posterior wall isolation (PWI) may reduce atrial fibrillation recurrence in patients with persistent atrial fibrillation. No data on PWI in paroxysmal AF (pAF) patients with normal left atrial voltage is available, to date.
Objective: This study sought to evaluate the efficacy of PWI in addition to pulmonary vein isolation (PVI) in patients presenting with pAF and normal left atrial voltage.
Int J Cardiol Heart Vasc
December 2021
Background: There is limited information on the long-term outcomes of ICDs in patients with inherited arrhythmia syndromes.
Methods: Prospective registry study of inherited arrhythmia patients with an ICD. Incidence of therapies and complications were measured as 5-year cumulative incidence proportions and analyzed with the Kaplan-Meier method.
Background: More than 3 million cardiovascular implantable electronic devices (CIEDs) are implanted annually. There are minimal data regarding the timing of diagnosis of acute complications after implantation. It remains unclear whether patients can be safely discharged less than 24 hours postimplantation.
View Article and Find Full Text PDFConducted energy weapon (commonly known as TASER) discharge in patients with implantable cardioverter-defibrillators is known to cause electromagnetic interference and inappropriate ventricular fibrillation sensing without delivery of implantable cardioverter-defibrillators therapy during conducted energy weapon application. We report the first known case of conducted energy weapon discharge resulting in inappropriate implantable cardioverter-defibrillators therapy. ().
View Article and Find Full Text PDFLack of legal regulation and oversight of scheduled drugs in Canada has led to an unsafe drug supply responsible for the deaths of tens of thousands. In addition to contributing to the worst unregulated drug poisoning crisis in Canada's history, the policy framework prohibiting non-medical access to certain drugs has exacerbated numerous public health and safety concerns. An alternative approach to prohibition is for government to retake control of the currently illegal drug market through legal regulatory mechanisms.
View Article and Find Full Text PDFBackground: The prolongation in QT interval typically observed following cardiac arrest is considered to be multifactorial and induced by external triggers such as hypothermia therapy and exposure to antiarrhythmic medications.
Objective: To evaluate the corrected QT interval (QTc) dynamics in the first 10 days following cardiac arrest with respect to the etiology of arrest, hypothermia and QT prolonging medications.
Methods: We enrolled 104 adult survivors of cardiac arrest, where daily ECG was available for at least 3 days.
The COVID-19 pandemic has resulted in worldwide morbidity at unprecedented scale. Troponin elevation is a frequent laboratory finding in hospitalized patients with the disease, and may reflect direct vascular injury or non-specific supply-demand imbalance. In this work, we assessed the correlation between different ranges of Troponin elevation, Electrocardiographic (ECG) abnormalities, and mortality.
View Article and Find Full Text PDFJ Interv Card Electrophysiol
January 2022
Purpose: Catheter ablation procedures for atrial fibrillation (AF) were significantly curtailed during the peak of coronavirus disease 2019 (COVID-19) pandemic to conserve healthcare resources and limit exposure. There is little data regarding peri-procedural outcomes of medical procedures during the COVID-19 pandemic. We enacted protocols to safely reboot AF ablation while limiting healthcare resource utilization.
View Article and Find Full Text PDFObjectives: This study sought to analyze high-frequency catheter excursion in relation to lesion quality markers in 20 consecutive patients undergoing first-time radiofrequency (RF) ablation for paroxysmal atrial fibrillation (AF).
Background: Ablation therapy for AF requires the delivery of durable lesions. The extent to which lesion sequence, catheter spatial stability, and anatomic location influence lesion formation during RF ablation of AF is not well understood.