Publications by authors named "Bernhard Weisse"

Background: Experimental knee implant wear testing according to ISO 14243 is a standard procedure, but it inherently possesses limitations for preclinical evaluations due to extended testing periods and costly infrastructure. In an effort to overcome these limitations, we hereby develop and experimentally validate a finite-element (FE)-based algorithm, including a novel cross-shear and contact pressure dependent wear and creep model, and apply it towards understanding the sensitivity of wear outcomes to the applied boundary conditions.

Methods: Specifically, we investigated the application of in vivo data for level walking from the publicly available "Stan" data set, which contains single representative tibiofemoral loads and kinematics derived from in vivo measurements of six subjects, and compared wear outcomes against those obtained using the ISO standard boundary conditions.

View Article and Find Full Text PDF

Following biomaterial implantation, a failure to resolve inflammation during the formation of a fracture hematoma can significantly limit the biomaterial's ability to facilitate bone regeneration. This study aims to combine the immunomodulatory and osteogenic effects of BMP-7 and IL-10 with the regenerative capacity of collagen-hydroxyapatite (CHA) scaffolds to enhance in vitro mineralization in a hematoma-like environment. Incubation of CHA scaffolds with human whole blood leads to rapid adsorption of fibrinogen, significant stiffening of the scaffold, and the formation of a hematoma-like environment characterized by a limited capacity to support the infiltration of human bone progenitor cells, a significant upregulation of inflammatory cytokines and acute phase proteins, and significantly reduced osteoconductivity.

View Article and Find Full Text PDF

Analysis of polyethylene (PE) wear in knee implants is crucial for understanding the factors leading to revision in total knee arthroplasty. Importantly, current experimental and computational methods for predicting insert wear can only be validated against true in vivo measurements from retrievals. This study quantitatively investigated in vivo PE wear rates in fixed-bearing (FB) (n = 21) and rotating-platform (n = 53) implant retrievals.

View Article and Find Full Text PDF

Despite availability of knee loads and kinematics data, conventional load- and displacement-controlled configurations still can't accurately predict tibiofemoral loads from kinematics or vice versa. We propose a combined load- and displacement-control method for joint-level simulations of the knee to reliably reproduce contact mechanics. Prediction errors of the new approach were compared to those of conventional purely load- or displacement-controlled models using implant loads and kinematics for multiple subjects and activities (CAMS-Knee dataset).

View Article and Find Full Text PDF

Millions of patients every year undergo gastrointestinal surgery. While often lifesaving, sutured and stapled reconnections leak in around 10% of cases. Currently, surgeons rely on the monitoring of surrogate markers and clinical symptoms, which often lack sensitivity and specificity, hence only offering late-stage detection of fully developed leaks.

View Article and Find Full Text PDF

Finite-element (FE) simulations that go beyond the linear elastic limit of materials can aid the development of polymeric products such as stretch blow molded angioplasty balloons. The FE model requires the input of an appropriate elastoplastic material model. Up to the onset of necking, the identification of the hardening curve is well established.

View Article and Find Full Text PDF

Objective:  The goal of this study was to generate mandibular fractures in three regions of the diastema using a metal impactor to simulate a kick from a horse and to determine the mean deceleration in the initial phase of the impact event, the maximum contact force, the impact energy necessary to create a fracture and the duration of the impact.

Study Design:  Thirty heads of horses aged between 5 and 20 years and euthanatized for various reasons were used. The heads were attached to a steel bar at the occiput at an axial angle of 45 degrees so that the body of the mandible was positioned horizontally and directly under the trajectory of the impactor.

View Article and Find Full Text PDF

Knowledge of both tibio-femoral kinematics and kinetics is necessary for fully understanding knee joint biomechanics, guiding implant design and testing, and driving and validating computational models. In 2017, the CAMS-Knee datasets were presented, containing synchronized in vivo implant kinematics measured using a moving fluoroscope and tibio-femoral contact loads measured using instrumented implants from six subjects. However, to date, no representative summary of kinematics and kinetics obtained from measurements at the joint level of the same cohort of subjects exists.

View Article and Find Full Text PDF

Direct ink writing (DIW) is a promising extrusion-based 3D printing technology, which employs an ink-deposition nozzle to fabricate 3D scaffold structures with customizable ink formulations for tissue engineering applications. However, determining the optimal DIW process parameters such as temperature, pressure, and speed for the specific ink is essential to achieve high reproducibility of the designed geometry and subsequent mechano-biological performance for different applications, particularly for porous scaffolds of finite sizes (total volume > 1000 mm) and controlled pore size and porosity. The goal of this study was to evaluate the feasibility of fabricating Polycaprolactone (PCL) and bio-active glass (BG) composite-based 3D scaffolds of finite size using DIW.

View Article and Find Full Text PDF

Background: This study aims to analyze the effects of a novel dual-bearing shoulder prosthesis and a conventional reverse shoulder prosthesis on the deltoid and rotator cuff muscle forces for four different arm motions. The dual-bearing prosthesis is a glenoid-sparing joint replacement with a moving center of rotation. It has been developed to treat rotator cuff arthropathy, providing an increased post-operative functionality.

View Article and Find Full Text PDF

Objective:  The aim of this study was to evaluate the effect of reducing the bone to cast distance on the resistance of the pin to cyclic loading in equine transfixation pin casts.

Study Design:  Eleven pairs of cadaveric equine third metacarpal bones were prepared and one 6.3/8.

View Article and Find Full Text PDF

Passive rotational stiffness of the osseo-ligamentous spine is an important input parameter for estimating in-vivo spinal loading using musculoskeletal models. These data are typically acquired from cadaveric testing. Increasingly, they are also estimated from subject-specific imaging-based finite element (FE) models, which are typically built from CT/MR data obtained in supine position and employ pure rotation kinematics.

View Article and Find Full Text PDF

Objective:  The aim of this study was to evaluate cyclic fatigue behaviour of a new pin with a thread run-out design in comparison with three other types of pins commonly used for equine transfixation pin casting.

Materials And Methods:  Twenty-four pairs of equine cadaveric third metacarpal bones (MC3) equipped with one transfixation pin placed horizontally in the distal metaphysis were tested using a simplified model, mimicking the biomechanical situation of equine transfixation pin casting. A 6.

View Article and Find Full Text PDF

Translational vertebral motion during functional tasks manifests itself in dynamic loci for center of rotation (COR). A shift of COR affects moment arms of muscles and ligaments; consequently, muscle and joint forces are altered. Based on posture- and level-specific trends of COR migration revealed by in vivo dynamic radiography during functional activities, it was postulated that the instantaneous COR location for a particular joint is optimized in order to minimize the joint reaction forces.

View Article and Find Full Text PDF

This study addresses the hypothesis that adjacent segment intervertebral joint loads are sensitive to the degree of lordosis that is surgically imposed during vertebral fusion. Adjacent segment degeneration is often observed after lumbar fusion, but a causative mechanism is not yet clearly evident. Altered kinematics of the adjacent segments and potentially nonphysiological mechanical joint loads have been implicated in this process.

View Article and Find Full Text PDF

Purpose: To determine conditions for the safe use of radiofrequency (RF) tissue ablation probes that avoid damaging suture material.

Methods: Four sutures made of 3 different materials commonly used in arthroscopic procedures were analyzed in a saline bath related to effects of RF-produced heat by proximity, duration, and intensity settings measuring burn-through time and ultimate load to failure. The parameters tested were electrode-to-suture distance, power setting, and the presence of tendon tissue or metallic anchor eyelets.

View Article and Find Full Text PDF

OpenSim offers a valuable approach to investigating otherwise difficult to assess yet important biomechanical parameters such as joint reaction forces. Although the range of available models in the public repository is continually increasing, there currently exists no OpenSim model for the computation of intervertebral joint reactions during flexion and lifting tasks. The current work combines and improves elements of existing models to develop an enhanced model of the upper body and lumbar spine.

View Article and Find Full Text PDF

Diamond like carbon (DLC) coatings have been proven to be an excellent choice for wear reduction in many technical applications. However, for successful adaption to the orthopaedic field, layer performance, stability and adhesion in physiologically relevant setups are crucial and not consistently investigated. In vitro wear testing as well as adequate corrosion tests of interfaces and interlayers are of great importance to verify the long term stability of DLC coated load bearing implants in the human body.

View Article and Find Full Text PDF

Purpose: Symptomatic adjacent segment disease (ASD) has been reported to occur in up to 27 % of lumbar fusion patients. A previous study identified patients at risk according to the difference of pelvic incidence and lordosis. Patients with a difference between pelvic incidence and lumbar lordosis >15° have been found to have a 20 times higher risk for ASD.

View Article and Find Full Text PDF

Understanding the kinematics of the spine provides paramount knowledge for many aspects of the clinical analysis of back pain. More specifically, visualisation of the instantaneous centre of rotation (ICR) enables clinicians to quantify joint laxity in the segments, avoiding a dependence on more inconclusive measurements based on the range of motion and excessive translations, which vary in every individual. Alternatively, it provides motion preserving designers with an insight into where a physiological ICR of a motion preserving prosthesis can be situated in order to restore proper load distribution across the passive and active elements of the lumbar region.

View Article and Find Full Text PDF

The human spinal segment is an inherently complex structure, a combination of flexible and semi-rigid articulating elements stabilised by seven principal ligaments. An understanding of how mechanical loading is shared among these passive elements of the segment is required to estimate tissue failure stresses. A 3D rigid body model of the complete lumbar spine has been developed to facilitate the prediction of load sharing across the passive elements.

View Article and Find Full Text PDF

The aim of this article is to present the optimization of a proof test procedure of ceramic hip joint ball heads. The proof test rejects defective samples in the production line before being implanted into human body. Thereby on every ceramic ball head a static load is applied, which is somewhat higher than the maximum physiological load.

View Article and Find Full Text PDF