Aims: The purpose of the present analysis was to identify predictors of procedural success of percutaneous transcatheter aortic valve implantation (TAVI).

Methods And Results: We prospectively assessed in-hospital outcome of patients undergoing TAVI at two institutions. We analysed clinical, morphological, and procedural parameters using univariate and multivariate regression models.

View Article and Find Full Text PDF

Background: Percutaneous aortic valve replacement is a new emerging technology for interventional treatment of severe aortic valve stenosis in surgical high-risk patients. This study was intended to provide a summary of the development and current safety and efficacy status of the self-expanding CoreValve Revalving prosthesis.

Method And Results: Between 2005 and 2008, we have enrolled 136 consecutive patients with percutaneous aortic valve replacement using the CoreValve prosthesis.

View Article and Find Full Text PDF

Objectives: We sought to determine both the procedural performance and safety of percutaneous implantation of the second (21-French [F])- and third (18-F)-generation CoreValve aortic valve prosthesis (CoreValve Inc., Irvine, California).

Background: Percutaneous aortic valve replacement represents an emerging alternative therapy for high-risk and inoperable patients with severe symptomatic aortic valve stenosis.

View Article and Find Full Text PDF

Background: The morbidity and mortality of surgical aortic valve replacement are increased in elderly patients with multiple high-risk comorbid conditions. Therefore, a prospective, single-center, nonrandomized study was performed in high-risk patients with aortic valve disease to evaluate the feasibility and safety of percutaneous implantation of a novel self-expanding aortic valve bioprosthesis (CoreValve).

Methods And Results: Symptomatic high-risk patients with an aortic valve area <1 cm2 were considered for enrollment.

View Article and Find Full Text PDF

Background: Percutaneous aortic valve replacement is a new technology for the treatment of patients with significant aortic valve stenosis. We present the first report on a human implantation of a self-expanding aortic valve prosthesis, which is composed of three bovine pericardial leaflets inserted within a self-expanding nitinol stent. The 73-year-old woman presented with severe symptomatic aortic valve stenosis (mean transvalvular gradient of 45 mmHg; valve area of 0.

View Article and Find Full Text PDF

Pediatric cardiac transplantation is currently an accepted option for end-stage heart disease and congenital cardiac malformations. This report focuses on the anesthetic perioperative management in 12 yr. From 1988 to 2001 we performed 90 heart transplantations in 88 children, infants and neonates.

View Article and Find Full Text PDF

Objective: To investigate whether generation and liberation of bradykinin and histamine contribute to generalized edema formation in pediatric cardiopulmonary bypass surgery.

Design: Prospective observational study.

Setting: Pediatric heart surgery of a university hospital.

View Article and Find Full Text PDF

Objective: The study was designed to evaluate changes in autonomic nervous system function during induction of anesthesia with fentanyl, midazolam, and pancuronium and to answer the question of dose-dependency of these effects.

Design: Prospective, randomized.

Setting: A university hospital.

View Article and Find Full Text PDF

Withdrawal of autologous plasma offers the possibility of improving patients' hemostasis and of reducing homologous blood consumption in cardiac surgery. The influence of acute, preoperatively performed plasmapheresis (APP) on platelet function was investigated in elective aortocoronary bypass patients subjected to APP producing either platelet-poor plasma (PPP; group 1; n = 12) or platelet-rich plasma (PRP; group 2; n = 12). APP-treated patients were randomly compared to patients without APP (control group; n = 12).

View Article and Find Full Text PDF

The effects of aortic stenosis (AS) on right ventricular function during cardiac surgery are not fully understood. Forty patients undergoing aortic valve replacement with either a systolic transvalvular gradient of less than 100 mm Hg (82.1 +/- 5.

View Article and Find Full Text PDF

Elderly patients undergoing cardiac surgery are reported to be at a higher risk for circulatory failure than younger patients, most likely because of ventricular decompensation. To assess the role of the right heart in these patients, right ventricular (RV) hemodynamics in 40 consecutive elderly patients (greater than 70 years; mean = 77.1 +/- 3.

View Article and Find Full Text PDF

Complex interrelationships exist between the right (RV) and the left ventricles (LV). Therefore, in 30 consecutive patients with reduced LV function (left ventricular ejection fraction [LVEF]) less than 40% undergoing myocardial revascularization, RV hemodynamics were studied from the beginning of anesthesia until the end of the operation. The data were compared with 30 consecutive patients with normal LVEF (greater than 70%).

View Article and Find Full Text PDF

Preoperative hemodilution (HD) is a recommended practice in cardiac surgery that conserves blood and reduces the complications of homologous blood transfusion. In 45 patients undergoing myocardial revascularization, HD was performed preoperatively. Withdrawn volume (10 mL/kg) was replaced either by a new hypertonic saline (HS) solution prepared in hydroxyethyl starch (HES) (2,400 mOsm/L, HS-HES group, n = 15) or by a standard low molecular weight hydroxyethyl starch solution (6% HES 200/0.

View Article and Find Full Text PDF