Purpose: Radiotherapy escalating dose rates above 50Gys, might offer a great potential in treating tumours while further sparing healthy tissue. However, these ultra-high intensities of FLASH-RT lead to new challenges with regard to dosimetry and beam monitoring. FLASH experiments at HIT (Heidelberg Ion Beam Therapy Center) and at GSI (GSI Helmholtz Centre for Heavy Ion Research) have shown a significant loss of signal in the beam monitoring system due to recombination effects.
View Article and Find Full Text PDFInt J Radiat Oncol Biol Phys
March 2022
Purpose: To establish a beam monitoring and dosimetry system to enable the FLASH dose rate carbon ion irradiation and investigate, at different oxygen concentrations, the in vitro biological response in comparison to the conventional dose rate.
Methods And Materials: CHO-K1 cell response to irradiation at different dose rates and at different levels of oxygenation was studied using clonogenic assay. The Heidelberg Ion-Beam Therapy Center (HIT) synchrotron, after technical improvements, was adjusted to extract ≥5 × 10C ions within approximately 150 milliseconds.
Several techniques are under development for image-guidance in particle therapy. Positron (β) emission tomography (PET) is in use since many years, because accelerated ions generate positron-emitting isotopes by nuclear fragmentation in the human body. In heavy ion therapy, a major part of the PET signals is produced by β-emitters generated projectile fragmentation.
View Article and Find Full Text PDFIntroduction: Physician adherence, or lack therefore, to diabetes care and follow-up guidelines may be linked to the rates of achieving suboptimal glycaemic, blood pressure and lipid targets in people with type 2 diabetes mellitus (T2DM). In this cross-sectional study we evaluated physician adherence to the patient follow-up protocol (PFP) of the 2017 Hellenic Diabetes Association (HDA) guidelines and also assessed glycated haemoglobin (HbA), blood pressure and lipid control achievement rates in the routine care setting in Greece.
Methods: Eligible subjects were adults with T2DM receiving oral hypoglycaemic agents (OHAs) for ≥ 1 year who had ≥ 2 HbA measurements in the previous year and an HbA target < 7%.
In particle therapy, the x-ray based treatment planning converting photon attenuation values to relative stopping power ratio (RSP) introduces clinically relevant range uncertainties. Recently, novel imaging technologies using transmission ion beams have been investigated to directly assess the water equivalent thickness (WET) of tissue, showing improved accuracy in RSP reconstruction, while potentially reducing the imaging dose. Due to their greater availability, protons have been mostly used for ion imaging.
View Article and Find Full Text PDFIntroduction: Systematic patient education has been reported to improve adherence to treatment, leading to better clinical outcomes. This cluster randomized real-world study investigated the effect of a systematic education program and telephone support on self-reported adherence to oral glucose-lowering treatment in patients with type 2 diabetes mellitus (T2DM).
Methods: Centers were randomized (1:1) to provide either standard-of-care (control group) or standard-of-care along with the education program and telephone support (empowerment group).
Exp Clin Endocrinol Diabetes
April 2020
Background: Metformin, in the absence of contraindications or intolerance, is recommended as first-line treatment for patients with type 2 diabetes mellitus (T2DM). This observational, retrospective study assessed the real-world adequacy of glycaemic control in Greek patients with T2DM initiating metformin monotherapy at maximum tolerated dose.
Methods: Included patients received metformin monotherapy for ≥24 months; relevant patient data were collected immediately prior to metformin initiation (baseline) and at other prespecified time points.
Aims: To characterize survival in relation to achieved glycated haemoglobin (HbA1c) level within alternative glucose-lowering regimens with differing risks of hypoglycaemia.
Methods: Data were extracted from the UK Clinical Practice Research Datalink and the corresponding Hospital Episode Statistics. Patients with type 2 diabetes prescribed glucose-lowering therapy in monotherapy or dual therapy with metformin between 2004 and 2013 were identified.
Ion beam therapy offers the possibility of a highly conformal tumor-dose distribution; however, this technique is extremely sensitive to inaccuracies in the treatment procedures. Ambiguities in the conversion of Hounsfield units of the treatment planning x-ray CT to relative stopping power (RSP) can cause uncertainties in the estimated ion range of up to several millimeters. Ion CT (iCT) represents a favorable solution allowing to directly assess the RSP.
View Article and Find Full Text PDFThis article reports on the development and the first applications of a new spectrometer which enables the precise and time-resolved measurement of both the energy loss and the charge-state distribution of ion beams with 10 < Z < 30 at energies of 4-8 MeV/u after their interaction with a laser-generated plasma. The spectrometer is based on five 20 × 7 mm(2) large and 20 μm thick polycrystalline diamond samples produced via the Chemical Vapour Deposition (CVD) process and was designed with the help of ion-optical simulations. First experiments with the spectrometer were successfully carried out at GSI using (48)Ca ions at an energy of 4.
View Article and Find Full Text PDF