Objectives: Posterior metal ceramic crowns are still widely used as a standard treatment. The aim of this study was to obtain long-term data on their clinical performance.

Material And Methods: Ten private practitioners participated in this prospective practice-based study.

View Article and Find Full Text PDF

Background: Ablative tumor surgery often results in continuity defects of the mandible. When an immediate reconstruction using autologous bone grafts is not possible the bridging of the defects with a variety of bridging plates might be achieved. However, those bridging plates have the risk of plate fractures or exposure.

View Article and Find Full Text PDF

Maxillary obturator prostheses with hollow metal obturators can be made of titanium to reduce weight. To prevent perforation of the hollow obturator during modifications, the obturator is slightly undersized and covered with a replaceable cap. This cap is made of a soft copolymer to facilitate uncomplicated modifications in the resection area and to improve function.

View Article and Find Full Text PDF

Purpose: At the moment, there is an inadequate margin fit of commercially available stoma buttons. The aim of the present study was to develop a customized short tracheal cannula based on digital data. Furthermore, the applied material has to be evaluated considering germ colonization and appropriate cleaning procedures.

View Article and Find Full Text PDF

Statement Of Problem: The 2-step putty and wash impression technique is commonly used in fixed prosthodontics. However, cutting sluiceways to allow the light-body material to drain is time-consuming. A solution might be the use of a spacer foil.

View Article and Find Full Text PDF

Objectives: The reconstruction of mandibular continuity defects by bridging plates often leads to complications. Customized mandibular implants might be an alternative option. In the present study, the stability at the bone-implant-interface of customized two-piece implants was compared to one-piece implants.

View Article and Find Full Text PDF

Background: Ablative surgery of oropharyngeal tumors frequently leads to defects in the speech organs, resulting in impairment of speech up to the point of unintelligibility. The aim of the present study was the assessment of selected parameters of speech with and without resection prostheses.

Patients And Methods: The speech sounds of 22 patients suffering from maxillary and mandibular defects were recorded using a digital audio tape (DAT) recorder with and without resection prostheses.

View Article and Find Full Text PDF

Mandibular tumor resection can lead to a mandibular segmental defect. LaserCUSING® is used to produce a mandibular implant, designed to be identical to the shape of the mandibular defect. Novel microrough surfaces result from this generative technology.

View Article and Find Full Text PDF

Statement Of Problem: Metal ceramic restorations are widely used in prosthodontics, but long-term data on their clinical performance in private practice settings based on prospective trials are sparse.

Purpose: This clinical trial was designed to provide realistic long-term survival rates for different outcomes related to tooth loss, crown loss, and metal ceramic defect.

Material And Methods: Ninety-five participants were provided with 190 noble metal ceramic single crowns and 138 participants with 276 fixed dental prosthesis retainer crowns on vital posterior teeth.

View Article and Find Full Text PDF

Background: The study describes the development and implementation of a digital nose database in order to provide patients with nasal prostheses following rhinectomy. Mirrored data for computer-aided design (CAD) cannot be used due to the unpaired structure of the nose.

Materials And Methods: The faces of 202 people were digitized using a 3-dimension (3D) scanner.

View Article and Find Full Text PDF

Purpose: The goal of our efforts was to develop a modified drill that allows a safe milling of the dorsal osteophytes located close to the dura.

Methods: Usually a normal high-speed drill is used for the resection of uncarthrotic and spondylophytic bone. In one patient, we used our new high-speed drill close to the dura in an area, which is not easy reachable with a normal drill or a rongeur.

View Article and Find Full Text PDF

Background: The goal of the study was to evaluate the masticatory efficacy in patients who had been provided with resection prostheses after tumor removal in the maxillary/ mandibular region. These patients complained of impairment of masticatory function.

Patients And Methods: 3 groups of patients were compared under clinical-experimental conditions.

View Article and Find Full Text PDF

The esthetic result of an auricular prosthesis is influenced by the position of the prosthesis incorporating the implants. The entire surface of the patient's head is captured by means of a conventional computed tomography (CT). The digital data are used to mirror the contralateral unimpaired ear for restoration of the impaired side.

View Article and Find Full Text PDF

To assess the stability of osteosynthesis in diacapitular condylar fractures we compared fixation using ultrasound-aided resorbable pins with poly-(D,L)-lactide (SonicWeld® Rx, KLS Martin, Tuttlingen, Germany) with that of titanium screws in 20 pig mandibles, 10 in each group. Isolated diacapitular fractures were created using a surgical chisel. Ten fractures were each repositioned and fixed by two pins (17 and 11 mm long, 2.

View Article and Find Full Text PDF

Objectives: The aim of this study was to determine the compound strength of the fixation between 2 blocks of synthetic bone using ultrasound activated resorbable pins (regarding drill hole diameter) and compare them to fixation with titanium miniscrews. Resorbable pins were up to 17 mm long.

Study Design: Two synthetic bone blocks (Sawbone) were fixed by either a resorbable pin or miniscrew osteosynthesis.

View Article and Find Full Text PDF

A partial resection of the lower jaw often has to be carried out in the context of the surgical removal of tumours in the lower jaw, mouth and tongue-floor space and lower jaw fractures with loss of substance, benign bone lesions and extensive difficult inflammation of bone tissue, respectively. The primary reconstruction of the lower jaw after partial resection with loss of continuity is mainly important for functional and aesthetic reasons. The defects of lower jaw continuity are often bridged with metal plates to reconstruct the masticatory function of the lower jaw, temporarily or permanently.

View Article and Find Full Text PDF

The purpose of this study was to determine whether fixation of cranial bone segments using ultrasonically welded pin osteosynthesis showed differences in mechanical stability as compared to fixation of cranial bone segments using screw osteosynthesis. Right and left cranial bone segments from each of 16 young sheep were obtained by craniotomy and re-fixed: on the right with a mesh plate and pins, and on the left with a mesh plate and screws. All osteosynthesis materials consisted of PDLLA, fully amorphous polyactid.

View Article and Find Full Text PDF

Background: In a retrospective study, risk factors for complications after the bridging of mandibular defects using reconstruction plates were reviewed. Especially the loosening of the plate-screw-mandible complex should be analyzed with a finite element model in order to reduce plate complications in future.

Patients And Methods: We examined 60 patients who underwent a treatment with reconstruction plates after tumor resection during a period of 10 years.

View Article and Find Full Text PDF

Purpose: The aim of this study was to evaluate the clinical performance of metal-ceramic crowns placed in 10 private practices.

Materials And Methods: In this prospective clinical trial, 95 patients were provided with 190 noble-metal metal-ceramic single crowns.

Results: The 7-year survival rates of the crowns were 95.

View Article and Find Full Text PDF

An optical modeling process for facial regions and other body surfaces has been developed. The body part in question is digitized using optical 3-D metrology to obtain a comprehensive dataset. The data is then prepared for further use by smoothing the point clusters.

View Article and Find Full Text PDF

In order to reduce the stress caused to patients by conventional methods of modeling using computed tomography (CT) or magnetic resonance imaging (MRI), an optical modeling process has been developed for extraoral defects and body areas. The selected body part is digitized using optical 3-coordinate measuring technology, providing an extensive data record. This is adapted for further use by equalizing the point clouds to obtain a Computer Aided Design (CAD) model, which is converted to a physical model by means of a stereolithographic process.

View Article and Find Full Text PDF

Statement Of Problem: The dimensional accuracy of 1-piece frameworks cast from commercially pure titanium and used to accommodate supporting telescopic crowns has not been demonstrated.

Purpose: To compare dimensional changes incurred in frameworks cast from commercially pure titanium, a cobalt-chromium alloy, and a noble metal (gold) alloy.

Material And Methods: This study was based on 2 different models, both prepared to receive telescopic crowns: 1 with 4 dies, designed to measure dimensional changes of the castings in the horizontal plane; and another with 2 dies, designed to measure dimensional changes in the vertical plane.

View Article and Find Full Text PDF

Statement Of Problem: For some patients, radiation treatment is a part of tumor therapy in the head and neck area before and/or after surgery. The oral cavity and teeth are thereby frequently exposed to high doses of radiation. In this situation, electronic backscatter from dental materials may damage the surrounding soft tissue.

View Article and Find Full Text PDF

Three different methods for minimizing the bacterial contamination of the water system in a SIRONA C2 type dental unit were investigated sequentially. Without any decontamination method, water from the hand piece, air-water-jet and mouthwash were continuously contaminated by 10(3) to 10(5) colony forming units (cfu) of aerobic mesophilic bacteria per milliliter. A reduction to below 100 cfu/ml was achieved by continuous adding of a chemical microbicide based on hydrogen peroxide and silver ions.

View Article and Find Full Text PDF

Statement Of Problem: The clinical impact of posterior crown margin placement on gingival health has not been thoroughly quantified.

Purpose: This study evaluated the effect of posterior crown margin placement with multivariate analysis.

Material And Methods: Ten general dentists reviewed 240 patients with 480 metal-ceramic crowns in a prospective clinical trial.

View Article and Find Full Text PDF