Publications by authors named "Bernardo Stein"

The EVOLVE Short DAPT study demonstrated the safety of truncated dual antiplatelet therapy (DAPT) in patients with a high bleeding risk (HBR) treated with SYNERGY stent(s) (Boston Scientific Company, Marlborough, Massachusetts). In this population, bleeding and ischemic risk prediction may further inform DAPT decisions. This post hoc analysis of the EVOLVE Short DAPT study identified predictors of ischemic and bleeding events up to 15 months using Cox proportional hazard models.

View Article and Find Full Text PDF
Article Synopsis
  • Bioresorbable vascular scaffolds (BVS) were compared to cobalt chromium everolimus-eluting stents (CoCr-EES) in the ABSORB IV trial, which aimed to evaluate their long-term outcomes after using improved implantation techniques.
  • Results showed that after 5 years, BVS had a 17.5% rate of target lesion failure compared to 14.5% for CoCr-EES, indicating BVS had slightly worse outcomes overall, especially within the first 3 years.
  • Despite these differences, the recurrence of angina was similar between the two devices, suggesting that while BVS might not perform as well in terms of target lesion failure, overall patient experience with angina was comparable.
View Article and Find Full Text PDF

Background: The thin-strut SYNERGY stent has an abluminal everolimus-eluting bioabsorbable polymer coating designed to facilitate vascular healing and reduce risk of stent thrombosis. In the multicenter, randomized EVOLVE II trial (The EVOLVE II Clinical Trial to Assess the SYNERGY Stent System for the Treatment of Atherosclerotic Lesion[s]), SYNERGY was noninferior to the durable polymer PROMUS Element Plus everolimus-eluting stent for the primary end point of 1-year target lesion failure. Longer-term clinical follow-up will support the relative efficacy and safety of SYNERGY.

View Article and Find Full Text PDF

Background: Previous studies showed more adverse events with coronary bioresorbable vascular scaffolds (BVS) than with metallic drug-eluting stents (DES), although in one randomised trial angina was reduced with BVS. However, these early studies were unmasked, lesions smaller than intended for the scaffold were frequently enrolled, implantation technique was suboptimal, and patients with myocardial infarction, in whom BVS might be well suited, were excluded.

Methods: In the active-controlled, blinded, multicentre, randomised ABSORB IV trial, patients with stable coronary artery disease or acute coronary syndromes aged 18 years or older were recruited from 147 hospitals in five countries (the USA, Germany, Australia, Singapore, and Canada).

View Article and Find Full Text PDF

Aims: Bioabsorbable polymer drug-eluting stents (DES) may reduce the inflammation and delayed healing associated with some permanent polymer-coated DES. Whether late clinical outcomes are improved, particularly among patients with medically treated diabetes, is unknown. Therefore, we analysed outcomes from a pre-specified substudy of the EVOLVE II trial to evaluate the safety and effectiveness of the SYNERGY stent in patients with diabetes mellitus.

View Article and Find Full Text PDF

In this paper, we explore mid-level image representations for real-time heart view plane classification of 2D echocardiogram ultrasound images. The proposed representations rely on bags of visual words, successfully used by the computer vision community in visual recognition problems. An important element of the proposed representations is the image sampling with large regions, drastically reducing the execution time of the image characterization procedure.

View Article and Find Full Text PDF

Background: Drug eluting stents with durable polymers may be associated with hypersensitivity, delayed healing, and incomplete endothelialization, which may contribute to late/very late stent thrombosis and the need for prolonged dual antiplatelet therapy. Bioabsorbable polymers may facilitate stent healing, thus enhancing clinical safety. The SYNERGY stent is a thin-strut, platinum chromium metal alloy platform with an ultrathin bioabsorbable Poly(D,L-lactide-co-glycolide) abluminal everolimus-eluting polymer.

View Article and Find Full Text PDF

Background: Pixel-level tissue classification for ultrasound images, commonly applied to carotid images, is usually based on defining thresholds for the isolated pixel values. Ranges of pixel values are defined for the classification of each tissue. The classification of pixels is then used to determine the carotid plaque composition and, consequently, to determine the risk of diseases (e.

View Article and Find Full Text PDF