This paper describes the most important articles that have been published on amino acid analysis using CE during the period from June 2009 to May 2011 and follows the format of the previous articles of Smith (Electrophoresis 1999, 20, 3078-3083), Prata et al. (Electrophoresis 2001, 22, 4129-4138) and Poinsot et al. (Electrophoresis 2003, 24, 4047-4062; Electrophoresis 2006, 27, 176-194; Electrophoresis 2008, 29, 207-223; Electrophoresis 2010, 31, 105-121).
View Article and Find Full Text PDFAn analytical methodology for quality control analyses of IgG and their impurities is presented using a new UV-LIF (266 nm) detector inside the cassette of a CE instrument and its performance was evaluated. The observed sensitivity was very close to that obtained by silver staining of slab gels (LOD of 25 ng/mL), while the sensitivity of the analysis is 80 times better than with CE/UV absorption (214 nm). Examples of the analysis of pharmaceutical and other commercial IgGs are provided and the kinetics of the reduction of IgG by beta-mercaptoethanol is reported, demonstrating the ease of performing the analysis.
View Article and Find Full Text PDFThis article describes the most important articles that have been published on amino acid analysis using CE during the period from June 2007 to May 2009. It follows the format of the previous articles of Smith [Electrophoresis 1999, 20, 3078-3083], Prata et al. [Electrophoresis 2001, 22, 4129-4138] and Poinsot et al.
View Article and Find Full Text PDFAn LIF detector was integrated into a CE system which uses a ball lens to focus the laser beam on the CE capillary. The detector employs an ellipsoid that is glued on the capillary window, to permit the collection of the fluorescence in the capillary. This 'trapped' fluorescence stays in the capillary because the angle of the silica/air interface is greater than the critical angle.
View Article and Find Full Text PDFThis paper describes a number of articles that have been published on amino acid (AA) analysis using CE during the period from June 2005 to May 2007. This review article follows the format of the previous articles of Smith (Electrophoresis 1999, 20, 3078-3083), Prata et al..
View Article and Find Full Text PDFThis paper describes a number of articles that have been published on amino acid analysis using CE during the period from June 2003 to May 2005. This review article follows the previous ones of Smith (Electrophoresis 1999, 20, 3078-3083), Prata et al. (Electrophoresis 2001, 22, 4129-4138), and Poinsot et al.
View Article and Find Full Text PDF