J Heart Lung Transplant
November 2024
Mechanical circulatory support devices have profoundly transformed the management of severe cardiothoracic disorders. While heart transplantation is the gold standard therapy for end-stage heart disease, long-term mechanical support devices are a viable alternative for those ineligible and/or those awaiting organ availability. Major technological advancements were made over first 5 decades of development, resulting in improved durability and survival with reduced adverse events.
View Article and Find Full Text PDFComprehensive optimization of rotodynamic blood pumps (RBPs) requires the consideration of three partially conflicting objectives: size, hemocompatibility, and motor efficiency. Optimizing these individual objectives independently, the potential of multiobjective optimizations often remains untapped. This study aimed at the multiobjective optimization of an RBP for cavopulmonary support accounting for all three objectives simultaneously.
View Article and Find Full Text PDFComputational fluid dynamics (CFD) is a powerful tool for the in-silico evaluation of rotodynamic blood pumps (RBPs). Corresponding validation, however, is typically restricted to easily accessible, global flow quantities. This study showcased the HeartMate 3 (HM3) to identify feasibility and challenges of enhanced in-vitro validation in third-generation RBPs.
View Article and Find Full Text PDFSemin Thorac Cardiovasc Surg
April 2022
Treatment of univentricular hearts remains restricted to palliative surgical corrections (Fontan pathway). The established Fontan circulation lacks a subpulmonary pressure source and is commonly accompanied by progressively declining hemodynamics. A novel cavopulmonary assist device (CPAD) may hold the potential for improved therapeutic management of Fontan patients by chronic restoration of biventricular equivalency.
View Article and Find Full Text PDFContemporary centrifugal continuous-flow left ventricular assist devices (LVADs) incorporate dynamic speed modulation algorithms. Hemocompatibility of these periodic unsteady pump operating conditions has been only partially explored. We evaluated whether speed modulation induces flow alterations associated with detrimental prothrombotic effects.
View Article and Find Full Text PDFHeart failure is a raising cause of mortality. Heart transplantation and ventricular assist device (VAD) support represent the only available lifelines for end stage disease. In the context of donor organ shortage, the future role of VAD as destination therapy is emerging.
View Article and Find Full Text PDFTreatment of heart failure with preserved ejection fraction (HFpEF) remains a major unmet medical need. An implantable valveless pulsatile pump with a single cannula-the CoPulse pump-may provide beneficial hemodynamic support for select HFpEF patients when connected to the failing ventricle. We aimed to demonstrate hemodynamic efficacy and hemocompatible design feasibility for this novel assist device.
View Article and Find Full Text PDFObjective: Mechanical circulatory support has become a standard therapy for adult patients with end-stage heart failure. For pediatric patients, technologic development lags behind with no currently approved implantable rotary blood pump. As an alternative, the HeartWare Ventricular Assist Device (Medtronic, Minneapolis, Minn), originally designed for adults, is increasingly used in pediatric patients.
View Article and Find Full Text PDFPulsatile positive displacement pumps as ventricular assist devices were gradually replaced by rotary devices due to their large volume and high adverse event rates. Nevertheless, pulsatile ventricular assist devices might be beneficial with regard to gastrointestinal bleeding and cardiac recovery. Therefore, aim of this study was to investigate the flow field in new pulsatile ventricular assist devices concepts with an increased pump frequency, which would allow lower stroke volumes to reduce the pump size.
View Article and Find Full Text PDFIn patients with a single ventricle, failure of the cardiovascular system may be prevented by substituting the missing sub-pulmonary ventricle with a pump. The aim of this study was to design and evaluate a device for long-term cavopulmonary support. A radial pump with two inlets and two outlets, a single impeller, mechanical bearings, and dual motor configuration was developed.
View Article and Find Full Text PDFFlow fields in rotary blood pumps (RBPs) have a significant influence on hemocompatibility. Because flow characteristics vary with flow rate, different operating conditions play a role. Furthermore, turbulence is crucial in the evaluation of blood damage potential, but the level of turbulence in implantable RBPs is still unknown.
View Article and Find Full Text PDFIn rotary blood pump recipients with low blood pressure pulsatility, current oscillometric methods to measure blood pressure are not applicable. The aim of this study was to use ultrasonic Doppler flow measurements to determine blood pressure in this patient population noninvasively. In 28 rotary blood pump recipients, blood pressure was measured three times with the developed Doppler method and compared to the invasive arterial line (n = 15) or to the oscillometric Terumo Elemano BP monitor (n = 13).
View Article and Find Full Text PDFPurpose: Effective treatment of patients with terminal heart failure and preserved ejection fraction (HFpEF) is an unmet medical need. The aim of this study was to investigate a novel valveless pulsatile pump as a therapeutic option for the HFpEF population through comprehensive in silico investigations.
Methods: The pump was simulated in a numerical model of the cardiovascular system of four HFpEF phenotypes and compared to a typical case of heart failure with reduced ejection fraction (HFrEF).
Objective: The hydraulic properties of implantable rotary blood pumps (RBPs) determine their interaction with the cardiovascular system. A systematic comparison in this regard has not yet been performed for different clinically used RBPs. The aim of this study is to describe the hydraulic characteristics of four RBPs with a universal mathematical model and to compare their behavior under clinical operating conditions.
View Article and Find Full Text PDFVentricular assist devices (VADs), among which the HeartMate 3 (HM3) is the latest clinically approved representative, are often the therapy of choice for patients with end-stage heart failure. Despite advances in the prevention of pump thrombosis, rates of stroke and bleeding remain high. These complications are attributed to the flow field within the VAD, among other factors.
View Article and Find Full Text PDFThe HeartWare HVAD is a radial rotary blood pump with a combination of passive magnetic and hydrodynamic bearings to levitate the impeller. The axial gap size between impeller and housing in this bearing and its sensitivity to speed, flow, and pressure difference is difficult to assess. Shear stresses are exceptionally high in this tiny gap making it important for blood damage and related adverse events.
View Article and Find Full Text PDFLeft ventricular assist devices (LVADs) have become a standard therapy for patients with severe heart failure. As low blood trauma in LVADs is important for a good clinical outcome, the assessment of the fluid loads inside the pump is critical. More specifically, the flow features on the surfaces where the interaction between blood and artificial material happens is of great importance.
View Article and Find Full Text PDFAim: In current rotary blood pumps, complications related to blood trauma due to shear stresses are still frequently observed clinically. Reducing the rotor tip speed might decrease blood trauma. Therefore, the aim of this project was to design a two-stage rotary blood pump leading to lower shear stresses.
View Article and Find Full Text PDFImplantable left ventricular assist devices (LVADs) became the therapy of choice in treating end-stage heart failure. Although survival improved substantially and is similar in currently clinically implanted LVADs HeartMate II (HM II) and HeartWare HVAD, complications related to blood trauma are frequently observed. The aim of this study was to compare these two pumps regarding their potential blood trauma employing computational fluid dynamics.
View Article and Find Full Text PDF