Publications by authors named "Benoit Sabot"

This work presents an outline of a detection system that employs the Compton spectrometer method to assess the non-linearity of scintillator light yield. A novel approach is introduced, leading to more accurate measurements through the separate determination of the intrinsic light output parameters and the non-linearity of the scintillators. Key features of this system include the use of a portable scintillation detector with three photomultiplier tubes for precise measurement of the average number of detected photoelectrons and the incorporation of recent advancements in correction techniques for accidental coincidences.

View Article and Find Full Text PDF
Article Synopsis
  • The study explores the use of stable barium (Ba) sources as substitutes for radioactive iodine (I) in nuclear medicine imaging, aiming to address uncertainties in calibration processes traditionally reliant on liquid radionuclide solutions.* -
  • Researchers created and tested multiple traceable Ba sources within various configurations, conducting quantitative SPECT/CT imaging across several member institutions to compare the effectiveness of Ba versus I.* -
  • Results indicate that, despite initial differences in calibration performance, a specific cross-calibration method allows Ba sources to effectively serve as surrogates for I, showcasing their potential in improving imaging accuracy and efficiency.*
View Article and Find Full Text PDF

Despite widespread radon-in-water measurements, no primary radon-in-water standards currently exist. This work aims to bridge this gap by developing a system to produce radon-in-water reference materials. The system relies on cryogenic, loss-free transfer of radon, which is standardized through defined solid angle measurements, to a radon standard in water.

View Article and Find Full Text PDF

In the Triple to Double Coincidence Ratio method in Liquid Scintillation Counting, the detection efficiency is calculated from the value of a free parameter describing the intrinsic light yield of the counting system. This model is generally based on a Poisson distribution of the number of photoelectrons detected and the detection efficiency is obtained from the complement of the non-detection efficiency. In the classical free parameter model, the mean of the Poisson distribution, m, is a constant but some variability of this mean could be expected from optical effects due to internal reflections inside the LS source or from non-homogeneity of the detection efficiency of the photomultiplier tubes.

View Article and Find Full Text PDF

The Bureau International des Poids et Mesures (BIPM) is developing a new transfer instrument to extend its centralized services for assessing the international equivalence of radioactive standards to new radionuclides. A liquid scintillation counter using the triple/double coincidence ratio method is being studied and tested in the CCRI(II)-P1.Co-60 pilot study.

View Article and Find Full Text PDF

A bilateral comparison to determine the activity concentration of the same I solution was organized. As electron-capture radionuclide with a rather high atomic number, I must be regarded as difficult to measure. The situation is partly exacerbated by the fact that some established standardization methods, like photon-photon coincidence counting, can no longer be applied due to the unavailability of appropriate equipment and expertise.

View Article and Find Full Text PDF

This work presents measurements of the half-lives of excited nuclear states of Np and Fe using a liquid scintillation (LS) spectrometer and a gamma detector. A novel approach for the determination of the half-lives of some excited states is presented which uses only LS counting data from a detector with two PMTs. The lifetime of the 1st and 2nd excited states of Fe were obtained without the use of a gamma detector.

View Article and Find Full Text PDF

This work explores the distribution of time intervals between signals from the photomultiplier tubes (PMTs) of a liquid scintillation counting (LSC) system when a scintillation burst caused by an ionizing particle is detected. This distribution is termed the cross-correlation distribution and it is shown that it contains information about the probability to detect a scintillation event. A theoretical model that describes the cross-correlation distribution is derived.

View Article and Find Full Text PDF

The responses of the three photomultiplier tubes (PMTs) in a triple-to-double coincidence ratio (TDCR) liquid scintillation (LS) system are often not identical. Such asymmetries can have a significant influence on activity determinations. The problem is often solved by means of a minimization algorithm which can easily be applied when analytical methods are used for the efficiency calculation, as is usually done for pure beta emitters.

View Article and Find Full Text PDF

A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_sessionbgum15qrc7f9d6t547nbtnsmhphrq7ec): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once