Background: Paroxysmal supraventricular tachycardia (PSVT) is a common episodic arrhythmia characterized by unpredictable onset and burdensome symptoms including palpitations, dizziness, chest pain, distress, and shortness of breath. Treatment of acute episodes of PSVT in the clinical setting consists of intravenous adenosine, beta-blockers, and calcium channel blockers (CCBs). Etripamil is an intranasally self-administered L-type CCB in development for acute treatment of AV-nodal dependent PSVT in a nonmedical supervised setting.

View Article and Find Full Text PDF

Background Self-administration of investigational intranasal L-type calcium channel blocker etripamil during paroxysmal supraventricular tachycardia (PSVT) appeared safe and well-tolerated in the phase 3 NODE-301 (Multi-Centre, Randomized, Double-Blind, Placebo-Controlled, Efficacy, and Safety Study of Etripamil Nasal Spray for the Termination of Spontaneous Episodes of Paroxysmal Supraventricular Tachycardia) trial of adults with sustained atrioventricular nodal-dependent PSVT. The NODE-302 open-label extension further characterized etripamil safety and efficacy. Methods and Results Eligible patients were monitored via self-applied cardiac monitoring system for 5 hours after etripamil self-administration.

View Article and Find Full Text PDF

Importance: Cardiac implantable electronic device (CIED) infection is a potentially devastating complication with an estimated 12-month mortality of 15% to 30%. The association of the extent (localized or systemic) and timing of infection with all-cause mortality has not been established.

Objective: To evaluate the association of the extent and timing of CIED infection with all-cause mortality.

View Article and Find Full Text PDF

Background: Pharmacologic termination of paroxysmal supraventricular tachycardia (PSVT) often requires medically supervised intervention. Intranasal etripamil, is an investigational fast-acting, nondihydropyridine, L-type calcium channel blocker, designed for unsupervised self-administration to terminate atrioventricular nodal-dependent PSVT. Phase 2 results showed potential safety and efficacy of etripamil in 104 patients with PSVT.

View Article and Find Full Text PDF

Background: The Prevention of Arrhythmia Device Infection Trial (PADIT) investigated whether intensification of perioperative prophylaxis could prevent cardiac implantable electronic device (CIED) infections. Compared with a single dose of cefazolin, the perioperative administration of cefazolin, vancomycin, bacitracin, and cephalexin did not significantly decrease the risk of infection. Our objective was to compare the microbiology of infections between study arms in PADIT.

View Article and Find Full Text PDF

Aims: Cardiac implantable electronic devices with device advisories have the potential of device malfunction. Remote monitoring (RM) of devices has been suggested to allow the identification of abnormal device performance and permit early intervention. We sought to describe the outcomes of patients with and without RM in devices subject to the Abbott Premature Battery Depletion (PBD) advisory with data from a Canadian registry.

View Article and Find Full Text PDF

Background: Premature or rapid battery depletion may compromise the performance and reliability of an implantable cardioverter defibrillator (ICD), potentially resulting in harm or death to patients. We sought to describe the outcomes and clinical management of devices included in the Abbott ICD Premature Battery Depletion Advisory, using data from a Canadian registry.

Methods: This prospective observational study includes patients with an Abbott device subject to the advisory, from 9 centres in Canada.

View Article and Find Full Text PDF

Aims: Post-operative pain following cardiac implantable electronic device (CIED) insertion is associated with patient dissatisfaction, emotional distress, and emergency department visits. We sought to identify factors associated with post-operative pain and develop a prediction score for post-operative pain.

Methods And Results: All patients from the BRUISE CONTROL-1 and 2 trials were included in this analysis.

View Article and Find Full Text PDF

Background: Cardiac implantable electronic device infection is a major complication that usually requires device removal. PADIT (Prevention of Arrhythmia Device Infection Trial) was a large cluster crossover trial of conventional versus incremental antibiotics.

Objectives: This study sought to investigate independent predictors of device infection in PADIT and develop a novel infection risk score.

View Article and Find Full Text PDF

Background: Oral anticoagulant use is common among patients undergoing pacemaker or defibrillator surgery. BRUISE CONTROL (Bridge or Continue Coumadin for Device Surgery Randomized Controlled Trial; NCT00800137) demonstrated that perioperative warfarin continuation reduced clinically significant hematomas (CSH) by 80% compared with heparin bridging (3.5% versus 16%).

View Article and Find Full Text PDF

Background: Anti-platelet therapy is commonly used in patients receiving oral anticoagulation and may increase bleeding risk among patients undergoing cardiac implantable electronic device (CIED) surgery. We sought to determine the proportion of anticoagulated patients who are concomitantly receiving anti-platelet therapy, the associated risk of clinically significant hematoma (CSH), and the proportion of patients in whom anti-platelet usage is guideline-indicated.

Methods: A secondary analysis of the Bridge or Continue Coumadin for Device Surgery Randomized Controlled Trial (BRUISE CONTROL).

View Article and Find Full Text PDF

Background: Infection of implanted medical devices has catastrophic consequences. For cardiac rhythm devices, pre-procedural cefazolin is standard prophylaxis but does not protect against methicillin-resistant gram-positive organisms, which are common pathogens in device infections.

Objective: This study tested the clinical effectiveness of incremental perioperative antibiotics to reduce device infection.

View Article and Find Full Text PDF

Aims: Guidelines recommend warfarin continuation rather than heparin bridging for pacemaker and defibrillator surgery, after the BRUISE CONTROL trial demonstrated an 80% reduction in device pocket haematoma with this approach. However, direct oral anticoagulants (DOACs) are now used to treat the majority of patients with atrial fibrillation. We sought to understand the best strategy to manage the DOACs at the time of device surgery and specifically hypothesized that performing device surgery without DOAC interruption would result in a reduced haematoma rate.

View Article and Find Full Text PDF

Purpose: Femoral venous access is required for most electrophysiology procedures. Limited data are available regarding post-procedure venous thromboembolism (VTE), specifically deep vein thrombosis (DVT) and pulmonary embolism (PE). Potential preventative strategies are unclear.

View Article and Find Full Text PDF

Background: There is no nonparenteral medication for the rapid termination of paroxysmal supraventricular tachycardia.

Objectives: The purpose of this study was to assess the efficacy and safety of etripamil nasal spray, a short-acting calcium-channel blocker, for the rapid termination of paroxysmal supraventricular tachycardia (SVT).

Methods: This phase 2 study was performed during electrophysiological testing in patients with previously documented SVT who were induced into SVT prior to undergoing a catheter ablation.

View Article and Find Full Text PDF

Background: The Riata lead advisory was announced in 2011 and has posed unique management challenges because of cable externalization and insulation abrasion, in some cases leading to sudden loss of defibrillation.

Objective: The purpose of this study was to provide further data on the rate of electrical failure in a population of patients with a Riata lead under advisory.

Methods: Using the Canadian Registry of Electronic Device Outcomes, prospective follow-up data were collected on 1352 Riata leads under advisory in 17 implantable cardioverter-defibrillator (ICD) implantation centers in Canada.

View Article and Find Full Text PDF

Aims: Cardiac implantable electronic device (CIED) surgery is commonly performed in patients with atrial fibrillation (AF). The current analysis was undertaken to compare peri-operative anticoagulation management, bleeding, and thrombotic events in AF patients treated with dabigatran vs. warfarin.

View Article and Find Full Text PDF

Background: The Riata lead under advisory has posed a unique clinical scenario where inside-out abrasion results in externalization of conductor cables, with a higher risk of electrical failure. We developed a comprehensive registry to assist with clinical management of this lead.

Methods And Results: This Canadian registry reports the findings of 3763 (74.

View Article and Find Full Text PDF

OBJECTIVE Endovascular treatment of aneurysms may result in incomplete initial occlusion and aneurysm recurrence at angiographic follow-up studies. This study aimed to assess the feasibility and efficacy of bipolar radiofrequency ablation (RFA) of aneurysm remnants after coil embolization. METHODS Bipolar RFA was accomplished using the coil mass as 1 electrode, while the second electrode was a stent placed across the aneurysmal neck.

View Article and Find Full Text PDF

Background: The BRUISE CONTROL trial (Bridge or Continue Coumadin for Device Surgery Randomized Controlled Trial) demonstrated that a strategy of continued warfarin during cardiac implantable electronic device surgery was safe and reduced the incidence of clinically significant pocket hematoma (CSH). CSH was defined as a post-procedure hematoma requiring further surgery and/or resulting in prolongation of hospitalization of at least 24 h, and/or requiring interruption of anticoagulation. Previous studies have inconsistently associated hematoma with the subsequent development of device infection; reasons include the retrospective nature of many studies, lack of endpoint adjudication, and differing subjective definitions of hematoma.

View Article and Find Full Text PDF

Background: Patients who require perioperative anticoagulation during cardiac implantable electronic device surgery are at increased risk for bleeding complications. The BRUISE CONTROL trial demonstrated that continuing warfarin was safer than heparin bridging, reducing the incidence of clinically significant pocket hematoma. Novel oral anticoagulants are being increasingly prescribed in place of warfarin.