Publications by authors named "Benjamin Bellon"

Surface design plays a critical role in determining the integration of dental implants with bone tissue. Femtosecond laser-texturing has emerged as a breakthrough technology offering excellent uniformity and reproducibility in implant surface features. However, when compared to state-of-the-art sandblasted and acid-etched surfaces, laser-textured surface designs typically underperform in terms of osseointegration.

View Article and Find Full Text PDF

Aims: To test whether titanium surface roughness disparity might be used to specifically guide the behavior of gingiva fibroblasts and keratinocytes, thereby improving the quality of soft tissue (ST) integration around abutments.

Methods: Titanium discs resembling the roughness of enamel (M) or cementum (MA) were created with normal or increased hydrophilicity and used as substrates for human fibroblasts and keratinocytes. Adhesion and proliferation assays were performed to assess cell-type specific responses upon encountering the different surfaces.

View Article and Find Full Text PDF

Objectives: The aim of the present study was to compare a novel tapered, double-threaded self-tapping tissue-Level design implant (TLC) to a well-established parallel walled tissue-level (TL) implant in terms of primary and secondary stability over time.

Materials And Methods: Test TLC (n = 10/per timepoint) and control TL (n = 10/per timepoint) implants were placed in the mandible of minipigs and left for submerged healing for 3, 6, and 12 weeks. Maximum insertion torque and implant stability quotient (ISQ) were measured for each implant at placement.

View Article and Find Full Text PDF

Aims: To histologically compare osseointegration and crestal bone healing between newly introduced tapered, self-cutting bone-level test implants and tapered bone-level control implants in sites with fully healed sites.

Methods: Sixty-six implants (33 test, 33 control) were placed 1 mm subcrestally in a minipig model and underwent qualitative histologic and quantitative histometric analyses after 3, 6 and 12 weeks of submerged healing. The primary and secondary outcomes were the bone-to-implant contact (BIC) and first bone-to-implant contact (fBIC).

View Article and Find Full Text PDF

Objectives: To investigate the impact of a Ti-Sr-O technology, applied to either a turned surface or an SLA surface, on the mechanical robustness of osseointegration, benchmarked against the SLActive surface.

Material And Methods: Ti discs (6.25-mm-diameter and 2-mm-thick) with three different surfaces were inserted on the proximal-anterior part of the tibial plateau of adult Swedish loop rabbits: (I) turned surface modified with Ti-Sr-O (turned + Ti-Sr-O), (II) SLA surface modified with Ti-Sr-O (SLA + Ti-Sr-O), and (III) SLActive surface (SLActive).

View Article and Find Full Text PDF

The purpose of this technical report is to present two novel experimental implant designs to boost data generation in preclinical in vivo research. Specifically, the report describes the rationale and the components of (1) a two-piece experimental implant suitable for a small animal platform (e.g.

View Article and Find Full Text PDF

Objectives: To examine factors influencing the primary stability of dental implants when stabilized in over-sized osteotomies using a calcium phosphate-based adhesive cement was the objective.

Methods: Using implant removal torque measurements as a surrogate for primary stability, we examined the influence of implant design features (diameter, surface area, and thread design), along with cement gap size and curing time, on the resulting primary implant stability.

Results: Removal torque values scaled with implant surface area and increasing implant diameters.

View Article and Find Full Text PDF

Aim: To histologically evaluate the influence of (1) loading and (2) grafting on osseointegration and peri-implant soft-tissue healing at immediately placed, self-cutting progressive tissue-level implants (TLX) in a minipig model.

Materials And Methods: TLX implants (n = 56) were immediately placed following the extraction of the mandibular first and second premolars, bilaterally, in a total of n = 14 minipigs. In each animal, the implant sites were allocated to the following four groups: (1) unloaded with simultaneous grafting using a bovine bone mineral; (2) unloaded without grafting; (3) loaded with simultaneous grafting; and (4) loaded without grafting.

View Article and Find Full Text PDF

Preclinical studies often require animal models for in vivo experiments. Particularly in dental research, pig species are extensively used due to their anatomical similarity to humans. However, there is a considerable knowledge gap on the multiscale morphological and mechanical properties of the miniature pigs' jawbones, which is crucial for implant studies and a direct comparison to human tissue.

View Article and Find Full Text PDF
Article Synopsis
  • Bone graft materials are used to fill bone defects and support implant placement, but current options often fail to be fully replaced by new bone within 3 to 6 months.
  • A new material called Bonewool, made from biodegradable PLGA fibers with ß-TCP nanoparticles, was tested against Bio-Oss, a common bovine hydroxyapatite graft.
  • The study found that Bonewool showed a more progressive degradation behavior, suggesting it could be fully resorbed, making it a promising alternative for bone augmentation.
View Article and Find Full Text PDF

Objectives: Immediate implant placement and loading is a practice that continues to gain traction in implant dentistry because it reduces treatment time and improves satisfaction. Novel implant designs that facilitate increased primary stability, while not compromising osseointegration and long-term survival are important to offer immediate solutions for missing teeth. Here, we hypothesize that fully tapered implants can obtain successful osseointegration with high survival rates after immediate loading in fresh extraction sockets and healed sites.

View Article and Find Full Text PDF

Objectives: To assess the osseointegration and crestal bone level maintenance of a novel fully tapered self-cutting tissue-level implant for immediate placement (test) compared to a clinically established tissue-level implant (control) in moderate bone quality.

Materials And Methods: Test and control implants were compared in 3 groups, i.e.

View Article and Find Full Text PDF

Surface chemistry and nanotopography of dental implants can have a substantial impact on osseointegration. The aim of this investigation was to evaluate the effects of surface chemistry and nanotopography on the osseointegration of titanium-zirconium (TiZr; Roxolid) discs, using a biomechanical pull-out model in rabbits. Two discs each were placed in both the right and left tibiae of 16 rabbits.

View Article and Find Full Text PDF

Objectives: Thermal and mechanical stresses during osteotomy preparation can impair implant osseointegration. This study investigated implant osseointegration following the measurement of temperature exposure during osteotomy drilling, varying drill design, sequence, and drill wear.

Materials And Methods: 36 tapered implants were placed in a mandibular minipig model after guided drilling of implant osteotomies using 4 different groups: (1) control drills with a conservative, sequential drilling sequence, (2) control drills using a shortened drill sequence (PF), (3) novel test drill displaying an optimized drill design and surface treatment, PF, and (4) aged test drill, PF.

View Article and Find Full Text PDF

Objectives: This study compared the osseointegrative potential of a novel injection molded zirconia dental implant (Neodent Zi ceramic implant, test) and a commercially available titanium implant (Neodent Alvim implant, control) in terms of histomorphometrically derived bone-to-implant contact (BIC), first bone-to-implant contact (fBIC), and the ratio of bone area to total area (BATA) around the implant.

Materials And Methods: A total of 36 implants, 18 per individual test device, were implanted in a split-mouth arrangement in either side of the edentulous and fully healed mandible of 6 minipigs. Histomorphometric analysis of BIC, fBIC, and BATA were performed 8 weeks post implantation and subjected to statistical non-inferiority testing.

View Article and Find Full Text PDF