Determination of angiotensin-converting enzyme (ACE) activity in cerebrospinal fluid (CSF) can help for establishing the diagnosis of neurosarcoidosis. We investigated the performance characteristics of two assays for ACE determination in 57 CSF, radiometry with [glycine-1-14C] benzoyl-L-histidyl-L-leucine and spectrophotometry with furylacryloyl-phenylalanyl-L-glycyl-L-glycine (FAPGG) as substrates. We compared both kinetic assays to an ELISA specific for human ACE.
View Article and Find Full Text PDFBlood angiotensin-converting enzyme (ACE) assay is now realized by the determination of enzyme activity on synthetic substrate, mostly furylacryloyl-phenylalanyl-L-glycyl-L-glycine (FAPGG). The matrix can be serum or heparin-plasma, with or without a separator; the assay developed on serum or plasma is not adapted to other matrix such as cerebrospinal fluid where the ACE activity is much lower. This assay has been adapted on a number of automated biochemistry analyzers with the specifications of the supplier of reagents, sometimes with modification of volumes or times for analysis.
View Article and Find Full Text PDFObjectives: We aimed to compare the use of nine different cardiac troponin (cTn) assays (2 cTnT and 7 cTnI) for the diagnosis of NSTEMI in a single multi-centre population.
Design And Methods: One hundred and fifty-eight patients were included (mean age 60 years, SD 17 years), including 23 patients (14%) with NSTEMI.
Results: The analytical comparison highlighted a large heterogeneity of cTn assays, as reflected by percentages of patients with detectable cTn, correlation coefficients, Passing-Bablok comparisons and concordance coefficients.
Sarcoidosis is a systemic granulomatous disease, which mostly affects lung. Central nervous system can be affected causing a neurosarcoidosis in 5 to 15% of all sarcoidosis patients. The definitive diagnosis is established on histological examination of brain granulomas.
View Article and Find Full Text PDFIntroduction: The role of the insertion/deletion (I/D) polymorphism in the angiotensin-converting enzyme gene (ACE) on acute myocardial infarction (AMI) is controversial.
Objectives: To assess the effect of the ACE I/D polymorphism on AMI compared with the healthy controls and its relationship with serum ACE activity in a Tunisian population.
Design And Methods: A total of 119 patients with AMI were compared with 238 healthy controls from the same geographical area.
Ethylene glycol poisoning is a medical emergency. Making a definitive diagnosis is challenging because few institutions have timely access to direct measurement of ethylene glycol. After ingestion, primary metabolism of ethylene glycol takes place in the liver, leading to glycolic acid and glyoxylic acid.
View Article and Find Full Text PDFIn October 2007, an 18-year-old woman with no cardiac history was admitted to the emergency department for a major epigastric pain. The chest pain led to assay cardiac troponin I (cTnI) with the emergency department point-of-care testing analyzer (Stratus CS), which disclosed a value of 0.70 ng/mL, discordant with the atypical clinical presentation and the noncontributive electrocardiography.
View Article and Find Full Text PDFBackground: GEM Premier 4000 (Instrumentation Laboratory), a new blood gas/CO-Oximeter/hematocrit/electrolyte/glucose/lactate analyzer was evaluated. The only reagents required were disposable cartridges (GEM Premier 4000 PAK comprise all components necessary for analysis, including quality controls).
Methods: The evaluation was performed in two laboratories according to the Valtec protocol guidelines.
During the past few decades, new technologies have allowed the fabrication of miniaturized sensors and the development of analyzers well designed for point-of-care testing (POCT). They combined the ease-of-use and portability required for POC with the accuracy and the reliability of traditional systems. Instrumentation Laboratory introduced the GEM Premier 3000, a compact and portable system to rapidly analyze pH, pCO2, PO2, Ca2+, Na2+, K+, lactate, glucose and hematocrit, from 135 microl of whole blood with a simple component: a cartridge, the GEM Premier Pak.
View Article and Find Full Text PDF