Introduction: The risk of complications associated with transvenous ICDs make the subcutaneous implantable cardiac defibrillator (S-ICD) a valuable alternative in patients with adult congenital heart disease (ACHD). However, higher S-ICD ineligibility and higher inappropriate shock rates-mostly caused by T wave oversensing (TWO)- are observed in this population. We report a novel application of deep learning methods to screen patients for S-ICD eligibility over a longer period than conventional screening.
View Article and Find Full Text PDFAnn Noninvasive Electrocardiol
July 2023
Background: Machine learning methods are used in the classification of various cardiovascular diseases through ECG data analysis. The concept of varying subcutaneous implantable cardiac defibrillator (S-ICD) eligibility, owing to the dynamicity of ECG signals, has been introduced before. There are practical limitations to acquiring longer durations of ECG signals for S-ICD screening.
View Article and Find Full Text PDFIntroduction: S-ICD eligibility is assessed at pre-implant screening where surface ECG traces are used as surrogates for S-ICD vectors. In heart failure (HF) patients undergoing diuresis, electrolytes and fluid shifts can cause changes in R and T waves. Subsequently, T:R ratio, a major predictor of S-ICD eligibility, can be dynamic.
View Article and Find Full Text PDFIndian Pacing Electrophysiol J
September 2022
Percutaneous catheter ablation is an effective and safe therapy that can eliminate ventricular tachycardia, reducing the risks of both recurrent arrhythmia and shock therapies from a defibrillator. Successful ablation requires accurate identification of arrhythmic substrate and the effective delivery of energy to the targeted tissue. A thorough pre-procedural assessment is needed before considered 3D electroanatomical mapping can be performed.
View Article and Find Full Text PDFBackground: A major predictor of eligibility of subcutaneous implantable cardiac defibrillators (S-ICD) is the T:R ratio. The eligibility cut-off of the T:R ratio incorporates a safety margin to accommodate for fluctuations of ECG signal amplitudes. We introduce a deep learning-based tool that accurately measures the degree of T:R ratio fluctuations and explore its role in S-ICD screening.
View Article and Find Full Text PDFBackground: This case report highlights the importance of recognizing that ventricular ectopy may be a cause for syncope and sudden cardiac death, through triggered disorganized arrhythmia. In the context of syncope, ventricular ectopy should be carefully assessed for coupling interval and morphology.
Case Presentation: A 39-year-old woman, who had presented with recurrent syncope, had a cardiac arrest shortly after admission that required emergency defibrillation.
Introduction: Haemodialysis patients who require defibrillator therapy are expected to benefit from the entirely avascular subcutaneous defibrillator (S-ICD), but haemodialysis is associated with dynamic changes in R and T wave amplitude which can impact S-ICD eligibility. A continuous assessment of S-ICD eligibility during haemodialysis has not previously been performed.
Material And Methods: Continuous surface ECG recordings were obtained from a cohort of patients undergoing maintenance haemodialysis, but without an indication for an ICD.
Aims: Approximately 5.7% of potential subcutaneous implantable cardioverter-defibrillator (S-ICD) recipients are ineligible by virtue of their vector morphology, with higher rates of ineligibility observed in some at-risk groups. Mathematical vector rotation is a novel technique that can generate a personalized sensing vector, one with maximal R:T ratio, using electrocardiogram (ECG) signal recorded from the present S-ICD location.
View Article and Find Full Text PDFPacing Clin Electrophysiol
February 2022
Introduction: Pre-implant ECG screening is performed to ensure that S-ICD recipients have at least one suitable sensing vector, yet cardiac over-sensing remains the commonest cause of inappropriate shock therapy in the S-ICD population. One explanation would be the presence of dynamic variations in ECG morphology that result in variations in vector eligibility.
Methods: Adult ICD patients had a 24-h ambulatory ECG performed using a digital Holter positioned to record all three S-ICD vectors.
J Cardiovasc Electrophysiol
January 2022
Introduction: Before ablation, predicting the site of origin (SOO) of outflow tract ventricular arrhythmia (OTVA), can inform patient consent and facilitate appropriate procedural planning. We set out to determine if OTVA variability can accurately predict SOO.
Methods: Consecutive patients with a clear SOO identified at OTVA ablation had their prior 24-h ambulatory ECGs retrospectively analysed (derivation cohort).
Subcutaneous Implantable Cardioverter-Defibrillators (S-ICDs) are used for prevention of sudden cardiac death triggered by ventricular arrhythmias. T Wave Over Sensing (TWOS) is an inherent risk with S-ICDs which can lead to inappropriate shocks. A major predictor of TWOS is a high T:R ratio (the ratio between the amplitudes of the T and R waves).
View Article and Find Full Text PDFBackground And Objective: The subcutaneous implantable cardioverter defibrillator (S-ICD) reduces mortality in individuals at high risk of sudden arrhythmic death, by rapid defibrillation of life-threatening arrhythmia. Unfortunately, S-ICD recipients are also at risk of inappropriate shock therapies, which themselves are associated with increased rates of mortality and morbidity. The commonest cause of inappropriate shock therapies is T wave oversensing (TWOS), where T waves are incorrectly counted as R waves leading to an overestimation of heart rate.
View Article and Find Full Text PDFIntramural septal substrate presents a challenge in patients undergoing ventricular tachycardia ablation, in terms of both accurate mapping and ablation with unipolar radiofrequency energy. We present the first use of the novel 2-F octapolar catheter in accurately defining intramural septal scar and facilitating bipolar ablation. ().
View Article and Find Full Text PDFIntroduction: Establishing the frequency and nature of arrhythmias in hemodialysis (HD) is an important step in improving outcomes of these patients. We undertook this systematic review and meta-analysis to characterize arrhythmia frequency in maintenance HD patients.
Methods: We identified studies on arrhythmias in adult patients on maintenance HD detected via implantable loop recorders (ILRs).
The British Heart Rhythm Society's are written for heart rhythm consultants, primary care physicians, specialist registrars, nurses and physiologists who may be requested to review ECGs or advise on cases where antipsychotic-induced QT prolongation is suspected or proven. The guidance is adapted from the latest Maudsley Prescribing Guidelines in Psychiatry, published in 2018.
View Article and Find Full Text PDFPermanent cardiac pacemakers have traditionally comprised a surgically implanted subcutaneous pulse generator affixed to at least one transvenous pacing lead. Despite technological advances, implant-related complications and transvenous-lead failure rates have remained high. The Micra Transcatheter Pacing System is a miniaturized single chamber pacemaker that is implanted directly into the right ventricle, eliminating the subcutaneous pocket and creating a leadless pacemaker system.
View Article and Find Full Text PDFObjective: At our tertiary cardiothoracic centre, cardiac MRI and thoracic CT scans are performed in patients with implanted LINQ devices. The degree of foreign body artefact associated with the LINQ device, and its clinical importance, has not previously been assessed. A case series review was therefore performed with a simultaneous review of patient safety and data loss events, secondary to the MRI environment.
View Article and Find Full Text PDFIn recent years, there has been a significant evolution in the field of cardiovascular implantable electronic devices (CIEDs). Pacemakers can now be leadless, implantable cardioverter defibrillators can be entirely subcutaneous and implantable loop recorders have become miniaturized. Driven by technological advances and an ageing population implant numbers have also steadily increased.
View Article and Find Full Text PDFPacing Clin Electrophysiol
June 2017
J Interv Card Electrophysiol
June 2017
Purpose: Bedside vascular ultrasound machines are increasingly available. They are used to facilitate safer vascular access across a number of different specialties. In the electrophysiology laboratory however, where patients are frequently anticoagulated and require the insertion of multiple venous sheaths, anatomical landmark techniques predominate.
View Article and Find Full Text PDFClin Med (Lond)
February 2017
Implantable cardiac devices have an increasingly important role. Pacemakers remain the only effective treatment for symptomatic bradycardia; cardiac resynchronisation therapy is a proven treatment for heart failure; and implantable cardioverter defibrillators (ICD) are superior to medical therapy in prevention of sudden cardiac death. Our ageing population has led to a rising number of device implants.
View Article and Find Full Text PDFRev Esp Cardiol (Engl Ed)
January 2017